7474 N ENCINO AVE 91406
Certificate Information: 7474 N ENCINO AVE 91406
- Application / Permit
- 23010-20000-03320
- Plan Check / Job No.
- B23VN11102
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- eplan NEW DETACHED 2-STORY ADU PER LAMC 12.22 A.33 (c)-(d)
- Permit Issued
- Issued on 9/8/2024
- Issuing Office
- Current Status
- CofO Issued on 4/10/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/21/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 9/7/2023 | MAHNAZ NOURHASHEMI |
| Corrections Issued | 9/16/2023 | MAHNAZ NOURHASHEMI |
| Quality Review Completed | 9/27/2023 | TU HUA |
| Applicant returned to address corrections | 6/21/2024 | MAHNAZ NOURHASHEMI |
| Applicant returned to address corrections | 7/25/2024 | MAHNAZ NOURHASHEMI |
| Plan Check Approved | 8/30/2024 | MAHNAZ NOURHASHEMI |
| Issued | 9/8/2024 | APPLICANT |
| CofO in Progress | 3/28/2025 | SALVADOR MARTINEZ |
| Permit Finaled | 4/10/2025 | RUBEN SALAS |
| Permit Finaled | 4/10/2025 | RUBEN SALAS |
| CofO Issued | 4/10/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 10/30/2023 | GABRIELLA TORRES |
| Eng Process Fee Ord 176,300 | Cleared | 11/1/2023 | GABRIELLA TORRES |
| Sewer availability | Cleared | 11/1/2023 | GABRIELLA TORRES |
| Low Impact Development (LID) | Cleared | 12/18/2023 | ROGELIO CORTES |
| Roof/Waste drainage to street | Cleared | 12/19/2023 | GABRIELLA TORRES |
| Construction near power lines | Cleared | 3/27/2024 | RIDWAN HARDY |
| Construction within easement | Cleared | 3/27/2024 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Sivushenka,, Mikita; Lic. No.: C87698 | 22814 DOLOROSA ST WOODLAND HILLS, CA 91367 |
Inspector Information
| MICHAEL CORTEZ, (818) 374-1176 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 10/2/2024 | Corrections Issued | GAREN HAYRAPETYAN |
| Underground Mechanical | 10/2/2024 | Corrections Issued | GAREN HAYRAPETYAN |
| PLUMBING-Rough | 10/7/2024 | Partial Approval | GAREN HAYRAPETYAN |
| Sewer | 10/10/2024 | Approved | SALVADOR MARTINEZ |
| Excavation/Setback/Form/Re-Bar | 10/15/2024 | Approved | SALVADOR MARTINEZ |
| Footing/Foundation/Slab | 10/15/2024 | Approved | SALVADOR MARTINEZ |
| Underground Mechanical | 10/15/2024 | Approved | SALVADOR MARTINEZ |
| Floor/Roof Diaphrgm/Shear Wall | 10/24/2024 | Partial Approval | SALVADOR MARTINEZ |
| Deputy Wood Construction | 10/30/2024 | Conditional Approval | RAUL OLAGI |
| Floor/Roof Diaphrgm/Shear Wall | 11/6/2024 | Partial Approval | SALVADOR MARTINEZ |
| PLUMBING-Rough | 11/6/2024 | Corrections Issued | SALVADOR MARTINEZ |
| PLUMBING-Rough | 11/8/2024 | Approved | SALVADOR MARTINEZ |
| ELECTRICAL-Rough | 11/12/2024 | Not Ready for Inspection | SALVADOR MARTINEZ |
| Floor/Roof Diaphrgm/Shear Wall | 11/12/2024 | Corrections Issued | SALVADOR MARTINEZ |
| BUILDING-Rough-Frame | 11/22/2024 | Approved | SALVADOR MARTINEZ |
| ELECTRICAL-Rough | 11/22/2024 | Partial Approval | SALVADOR MARTINEZ |
| Floor/Roof Diaphrgm/Shear Wall | 11/22/2024 | Approved | SALVADOR MARTINEZ |
| Green Building Rough | 11/22/2024 | Not Ready for Inspection | SALVADOR MARTINEZ |
| HVAC-Rough | 11/22/2024 | Partial Approval | SALVADOR MARTINEZ |
| Verify Sprinkler Sign Off | 11/22/2024 | Approved | SALVADOR MARTINEZ |
| ELECTRICAL-Rough | 12/10/2024 | Approved | SALVADOR MARTINEZ |
| Green Building Rough | 12/10/2024 | Approved | SALVADOR MARTINEZ |
| HVAC-Rough | 12/10/2024 | Approved | SALVADOR MARTINEZ |
| Interior/Exterior Lathing | 12/10/2024 | Partial Approval | SALVADOR MARTINEZ |
| Insulation | 12/18/2024 | Corrections Issued | SALVADOR MARTINEZ |
| Insulation | 12/23/2024 | Approved | LOUIS ESCOTO |
| Drywall Nailing | 12/27/2024 | Approved | MICHAEL CORTEZ |
| Interior/Exterior Lathing | 12/27/2024 | Not Ready for Inspection | MICHAEL CORTEZ |
| Interior/Exterior Lathing | 1/8/2025 | Approved | LOUIS ESCOTO |
| ELECTRICAL-Final | 2/10/2025 | Corrections Issued | SALVADOR MARTINEZ |
| Final | 2/10/2025 | Corrections Issued | SALVADOR MARTINEZ |
| Green Building Final | 2/10/2025 | Not Ready for Inspection | SALVADOR MARTINEZ |
| HVAC-Final | 2/10/2025 | Corrections Issued | SALVADOR MARTINEZ |
| PLUMBING-Final | 2/10/2025 | Corrections Issued | SALVADOR MARTINEZ |
| SGSOV-Seismic Gas S/O Valve | 2/10/2025 | SGSOV No Gas | SALVADOR MARTINEZ |
| Service/Power Release | 2/10/2025 | Not Ready for Inspection | SALVADOR MARTINEZ |
| Smoke Detectors | 2/10/2025 | Approved | SALVADOR MARTINEZ |
| Underground Mechanical | 2/10/2025 | Corrections Issued | SALVADOR MARTINEZ |
| PLUMBING-Final | 3/7/2025 | No Access for Inspection | RAUL OLAGI |
| Final | 3/11/2025 | Corrections Issued | SALVADOR MARTINEZ |
| Green Building Final | 3/11/2025 | Approved | SALVADOR MARTINEZ |
| Service/Power Release | 3/11/2025 | Not Ready for Inspection | SALVADOR MARTINEZ |
| Final | 3/26/2025 | OK to Issue CofO | SALVADOR MARTINEZ |
| Service/Power Release | 3/26/2025 | Approved | SALVADOR MARTINEZ |