8608 N SYLMAR AVE 91402
Certificate Information: 8608 N SYLMAR AVE 91402
- Application / Permit
- 23010-20000-02554
- Plan Check / Job No.
- B23VN08092
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- PROPOSE (N) TWO STORY 20'X25' ACCESSORY DWELLING UNIT_LAMC 12.22 A.33(c) and (d).
- Permit Issued
- Issued on 12/20/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 10/12/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/20/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 6/29/2023 | DAWN MC NULTY |
| Corrections Issued | 7/3/2023 | DAWN MC NULTY |
| Quality Review Completed | 7/7/2023 | STEVEN KIM |
| Building Plans Picked Up | 7/7/2023 | APPLICANT |
| Applicant returned to address corrections | 12/13/2023 | DAWN MC NULTY |
| Plan Check Approved | 12/20/2023 | DAWN MC NULTY |
| Issued | 12/20/2023 | APPLICANT |
| CofO in Progress | 9/26/2024 | GREGG CUMMINGS |
| CofO Issued | 10/12/2024 | DANIEL ORRANTE |
| Permit Finaled | 10/12/2024 | DANIEL ORRANTE |
Permit Application Clearance Information
| Construction near power lines | Cleared | 9/22/2023 | RIDWAN HARDY |
| Address approval | Cleared | 10/7/2023 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 10/10/2023 | CARLOS AGUILERA |
| Sewer availability | Cleared | 10/10/2023 | CARLOS AGUILERA |
| Hydrant and Access approval | Cleared | 11/8/2023 | MATTHEW CRAIG |
| Low Impact Development (LID) | Cleared | 11/27/2023 | ROGELIO CORTES |
| Roof/Waste drainage to street | Cleared | 11/28/2023 | CARLOS AGUILERA |
Contact Information
| Contractor | Ultimate Green Construction Inc; Lic. No.: 1023605-B | 13302 FILMORE ST PACOIMA, CA 91331 |
| Engineer | Morales,, Carlos Alberto; Lic. No.: C69972 | 38100 SAN MATEO AVE PALMDALE, CA 93551 |
Inspector Information
| OGANES TARAKHCHYAN, (818) 374-1162 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 1/12/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| PLUMBING-Rough | 1/12/2024 | Partial Approval | GREGG CUMMINGS |
| Deputy Reinf. Concrete | 1/17/2024 | Conditional Approval | GREGG CUMMINGS |
| Excavation/Setback/Form/Re-Bar | 1/17/2024 | Approved | GREGG CUMMINGS |
| Footing/Foundation/Slab | 1/17/2024 | Approved | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 1/29/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Floor/Roof Diaphrgm/Shear Wall | 1/29/2024 | Partial Approval | GREGG CUMMINGS |
| Green Building Rough | 1/29/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Verify Sprinkler Sign Off | 1/29/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Deputy Wood Construction | 2/22/2024 | Conditional Approval | DAVID MATSON |
| BUILDING-Rough-Frame | 3/11/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| ELECTRICAL-Rough | 3/11/2024 | Approved | GREGG CUMMINGS |
| Green Building Rough | 3/11/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| HVAC-Rough | 3/11/2024 | Approved | GREGG CUMMINGS |
| PLUMBING-Rough | 3/11/2024 | Approved | GREGG CUMMINGS |
| Underground Mechanical | 3/11/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Verify Sprinkler Sign Off | 3/11/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| BUILDING-Rough-Frame | 3/18/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Underground Mechanical | 3/18/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 3/21/2024 | Approved | GREGG CUMMINGS |
| Green Building Rough | 3/21/2024 | Approved | GREGG CUMMINGS |
| Underground Mechanical | 3/21/2024 | Approved | GREGG CUMMINGS |
| Verify Sprinkler Sign Off | 3/21/2024 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 4/4/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Shower Pan | 4/4/2024 | Approved | GREGG CUMMINGS |
| Insulation | 4/9/2024 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 4/9/2024 | Partial Approval | GREGG CUMMINGS |
| Drywall Nailing | 4/15/2024 | Approved | GREGG CUMMINGS |
| Interior/Exterior Lathing | 4/15/2024 | Partial Approval | GREGG CUMMINGS |
| Final | 8/20/2024 | Corrections Issued | GREGG CUMMINGS |
| Green Building Final | 8/20/2024 | Approved | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 8/20/2024 | SGSOV Not Ready | GREGG CUMMINGS |
| Service/Power Release | 8/20/2024 | Not Ready for Inspection | GREGG CUMMINGS |
| Smoke Detectors | 8/20/2024 | Approved | GREGG CUMMINGS |
| ELECTRICAL-Final | 9/25/2024 | Approved | GREGG CUMMINGS |
| Final | 9/25/2024 | OK to Issue CofO | GREGG CUMMINGS |
| HVAC-Final | 9/25/2024 | Approved | GREGG CUMMINGS |
| PLUMBING-Final | 9/25/2024 | Approved | GREGG CUMMINGS |
| SGSOV-Seismic Gas S/O Valve | 9/25/2024 | SGSOV Approved | GREGG CUMMINGS |
| Service/Power Release | 9/25/2024 | Approved | GREGG CUMMINGS |