10332 N JARDINE AVE 91040

Certificate Information: 10332 N JARDINE AVE 91040

Application / Permit
23010-20000-02296
Plan Check / Job No.
B23VN07186
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW 60'2" X 27'8" TWO STORY SFD WITH ATTACHED TWO GARAGE, NFPA-13D FIRE SPRINKLERS REQUIRED THROUGHOUT, ALL WORK PER ENGINEERING
Permit Issued
Issued on 12/29/2023
Issuing Office
Current Status
Issued on 12/29/2023
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 6/1/2023 APPLICANT
Assigned to Plan Check Engineer 6/15/2023 RARES BODEA
Corrections Issued 6/29/2023 RARES BODEA
Quality Review Completed 6/30/2023 STEVEN KIM
Building Plans Picked Up 7/3/2023 APPLICANT
Applicant returned to address corrections 10/17/2023 RARES BODEA
Applicant returned to address corrections 12/18/2023 RARES BODEA
Plan Check Approved 12/29/2023 STEVEN KIM
Issued 12/29/2023 APPLICANT

Permit Application Clearance Information

Address approval Cleared 8/10/2023 MEGAN GODINEZ
Eng Process Fee Ord 176,300 Cleared 8/14/2023 MEGAN GODINEZ
Sewer availability Cleared 8/14/2023 MEGAN GODINEZ
Hydrant and Access approval Cleared 9/30/2023 JOHN CONNEALLY
Trees in Parkway Cleared 10/2/2023 ADALBERTO VERA
Low Impact Development (LID) Cleared 10/6/2023 MELINEH AGHAKHABIAN
Permit Cleared 10/6/2023 COLIN LOREDO
Roof/Waste drainage to street Cleared 10/6/2023 COLIN LOREDO
GPI Written Notices Cleared 12/21/2023 RARES BODEA
Grading Pre-Inspection Cleared 12/21/2023 RARES BODEA

Contact Information

Contractor Owner-Builder       ,
Engineer Phillips,, Craig; Lic. No.: C69673 2123 VESTAL AVE      LOS ANGELES, CA 90026

Inspector Information

MATTHEW NELSON, (818) 374-1168 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 4/26/2024 Partial Approval DAVID ANDERSON
Posting Pre-Inspection 4/26/2024 Not Ready for Inspection DAVID ANDERSON
Footing/Foundation/Slab 6/3/2024 Corrections Issued DAVID ANDERSON
Pre-Inspection 6/3/2024 Approved DAVID ANDERSON
Excavation/Setback/Form/Re-Bar 6/12/2024 Corrections Issued DAVID ANDERSON
Pre-Inspection 6/12/2024 Approved DAVID ANDERSON
Footing/Foundation/Slab 6/14/2024 Partial Approval DAVID ANDERSON
Footing/Foundation/Slab 7/10/2024 Approved DAVID ANDERSON
BUILDING-Rough-Frame 9/20/2024 Not Ready for Inspection DAVID ANDERSON
Floor/Roof Diaphrgm/Shear Wall 9/20/2024 Partial Approval DAVID ANDERSON
Green Building Rough 9/20/2024 Not Ready for Inspection DAVID ANDERSON
Rough-Elec/Plmb/HVAC 9/20/2024 Not Ready for Inspection DAVID ANDERSON
Verify Sprinkler Sign Off 9/20/2024 Corrections Issued DAVID ANDERSON
ELECTRICAL-Rough 10/17/2024 Not Ready for Inspection DAVID ANDERSON
HVAC-Rough 10/17/2024 Not Ready for Inspection DAVID ANDERSON
PLUMBING-Rough 10/17/2024 Not Ready for Inspection DAVID ANDERSON
Wood Frame 10/17/2024 Not Ready for Inspection DAVID ANDERSON
Floor/Roof Diaphrgm/Shear Wall 10/24/2024 Corrections Issued DAVID ANDERSON
ELECTRICAL-Rough 12/9/2024 Not Ready for Inspection DAVID ANDERSON
PLUMBING-Rough 12/9/2024 Not Ready for Inspection DAVID ANDERSON
Verify Sprinkler Sign Off 12/9/2024 Approved DAVID ANDERSON
Deputy Wood Construction 12/10/2024 Conditional Approval DAVID MATSON
ELECTRICAL-Rough 1/16/2025 Approved DAVID ANDERSON
Shower Pan 1/16/2025 Approved DAVID ANDERSON
Special/Order Compliance 1/16/2025 Corrections Issued DAVID ANDERSON
ELECTRICAL-Rough 1/23/2025 Not Ready for Inspection DAVID ANDERSON
HVAC-Rough 1/23/2025 Not Ready for Inspection DAVID ANDERSON
PLUMBING-Rough 1/23/2025 Not Ready for Inspection DAVID ANDERSON
Wood Frame 1/23/2025 Not Ready for Inspection DAVID ANDERSON
BUILDING-Rough-Frame 2/4/2025 Not Ready for Inspection DAVID ANDERSON
Green Building Rough 2/4/2025 Approved DAVID ANDERSON
HVAC-Rough 2/4/2025 Approved DAVID ANDERSON
PLUMBING-Rough 2/4/2025 Approved DAVID ANDERSON
BUILDING-Rough-Frame 2/18/2025 Approved DAVID ANDERSON
HVAC-Rough 2/18/2025 Approved DAVID ANDERSON
Insulation 2/18/2025 Approved DAVID ANDERSON
Interior/Exterior Lathing 2/18/2025 Partial Approval DAVID ANDERSON
Wood Frame 2/18/2025 Approved DAVID ANDERSON
Drywall Nailing 2/25/2025 Approved DAVID ANDERSON