12040 W MAXWELLTON ROAD 91604
Certificate Information: 12040 W MAXWELLTON ROAD 91604
- Application / Permit
- 23010-10000-02970
- Plan Check / Job No.
- B23LA13369
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- New Two story single dwelling unit with attached garage
- Permit Issued
- Issued on 5/14/2024
- Issuing Office
- Current Status
- CofO in Progress on 6/1/2026
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 7/20/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 7/20/2023 | MANUEL MONTUFAR |
| Corrections Issued | 9/1/2023 | MANUEL MONTUFAR |
| Quality Review Completed | 9/5/2023 | EUGENE BARBEAU |
| Applicant returned to address corrections | 12/18/2023 | MANUEL MONTUFAR |
| Applicant returned to address corrections | 3/26/2024 | MANUEL MONTUFAR |
| Plan Check Approved | 5/14/2024 | MANUEL MONTUFAR |
| Issued | 5/14/2024 | APPLICANT |
| CofO in Progress | 6/1/2026 | CHRISTOPHE COCHRAN |
Permit Application Clearance Information
| GPI Written Notices | Cleared | 9/1/2023 | MANUEL MONTUFAR |
| Grading Pre-Inspection | Cleared | 9/1/2023 | MANUEL MONTUFAR |
| Address approval | Cleared | 10/14/2023 | CARLOS AGUILERA |
| Sewer availability | Cleared | 10/14/2023 | CARLOS AGUILERA |
| Disturb/Remove Protected Trees | Cleared | 10/18/2023 | ADALBERTO VERA |
| Trees in Parkway | Cleared | 10/18/2023 | ADALBERTO VERA |
| Hydrant and Access approval | Cleared | 12/2/2023 | JOHN CONNEALLY |
| Low Impact Development (LID) | Cleared | 1/11/2024 | PATRICK LOPEZ |
| Eng Process Fee Ord 176,300 | Cleared | 3/27/2024 | CARLOS AGUILERA |
| Permit | Cleared | 3/27/2024 | EDGAR ALCARAZ |
| Roof/Waste drainage to street | Cleared | 3/27/2024 | EDGAR ALCARAZ |
| Work Adjacent to Public Way | Cleared | 3/28/2024 | CARLOS AGUILERA |
| Miscellaneous | Cleared | 5/6/2024 | GEORGIA SMITH |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Almalla,, Dean; Lic. No.: C58024 | 15053 VENTURA BLVD STE 205 SHERMAN OAKS, CA 91403 |
| Engineer | Salehipour,, Sassan A; Lic. No.: GE2579 | 1290 N LAKE AVENUE #204 PASADENA, CA 91104 |
Inspector Information
| CHRISTOPHE COCHRAN, (818) 374-1165 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 8/8/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 8/14/2024 | Partial Approval | SALVADOR MARTINEZ |
| Footing/Foundation/Slab | 8/19/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| Deputy Reinf. Concrete | 8/20/2024 | Conditional Approval | JUAN VALENZUELA |
| Footing/Foundation/Slab | 8/29/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| Footing/Foundation/Slab | 9/6/2024 | Approved | CHRISTOPHE COCHRAN |
| Deputy Reinf. Concrete | 9/9/2024 | Conditional Approval | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 9/19/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| Deputy Drilled-In Anchors | 10/21/2024 | Conditional Approval | JUAN VALENZUELA |
| Deputy Wood Construction | 10/21/2024 | Conditional Approval | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 10/21/2024 | Partial Approval | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 11/19/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| HVAC-Rough | 11/19/2024 | Approved | CHRISTOPHE COCHRAN |
| Pre-Inspection | 12/4/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 12/17/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 12/17/2024 | Corrections Issued | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 2/14/2025 | Corrections Issued | CHRISTOPHE COCHRAN |
| PLUMBING-Rough | 2/14/2025 | Approved | CHRISTOPHE COCHRAN |
| ELECTRICAL-Rough | 2/19/2025 | Approved | CHRISTOPHE COCHRAN |
| Floor/Roof Diaphrgm/Shear Wall | 2/19/2025 | Partial Approval | CHRISTOPHE COCHRAN |
| Deputy Wood Construction | 2/21/2025 | Conditional Approval | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 2/28/2025 | Approved | CHRISTOPHE COCHRAN |
| Green Building Rough | 2/28/2025 | Approved | CHRISTOPHE COCHRAN |
| Verify Sprinkler Sign Off | 2/28/2025 | Approved | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 3/10/2025 | Partial Approval | MISAEL ESPARZA |
| Insulation | 3/20/2025 | Approved | CHRISTOPHE COCHRAN |
| Shower Pan | 3/20/2025 | Approved | CHRISTOPHE COCHRAN |
| Interior/Exterior Lathing | 4/1/2025 | Approved | CHRISTOPHE COCHRAN |
| Drywall Nailing | 4/8/2025 | Approved | MICHAEL CORTEZ |
| Pre-Inspection | 10/22/2025 | Approved | CHRISTOPHE COCHRAN |
| ELECTRICAL-Final | 3/19/2026 | Corrections Issued | CHRISTOPHE COCHRAN |
| HVAC-Final | 3/19/2026 | Corrections Issued | CHRISTOPHE COCHRAN |
| ELECTRICAL-Final | 5/6/2026 | Approved | JOSE AVILA |
| HVAC-Final | 5/6/2026 | Approved | JOSE AVILA |
| Final | 5/22/2026 | Corrections Issued | CHRISTOPHE COCHRAN |
| Green Building Final | 5/22/2026 | Approved | CHRISTOPHE COCHRAN |
| SGSOV-Seismic Gas S/O Valve | 5/22/2026 | SGSOV Approved | CHRISTOPHE COCHRAN |
| Service/Power Release | 5/22/2026 | Not Ready for Inspection | CHRISTOPHE COCHRAN |
| Smoke Detectors | 5/22/2026 | Approved | CHRISTOPHE COCHRAN |
| Final | 5/28/2026 | OK to Issue CofO | CHRISTOPHE COCHRAN |
| Service/Power Release | 5/28/2026 | Approved | CHRISTOPHE COCHRAN |