4171-4173 N BAKMAN AVE 91602

Certificate Information: 4171-4173 N BAKMAN AVE 91602

Application / Permit
23010-10000-02784
Plan Check / Job No.
B23LA12226
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
NEW SFD 38' X 55' 7" 2-STORY WITH ATTACHED GARAGE AND ADU PER STATE LAW CA Govt. Code 65852.2(e)(1)(A)9 NFPA13D REQUIRED THROUGHOUT
Permit Issued
Issued on 10/6/2023
Issuing Office
Valley
Current Status
CofO Issued on 12/24/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 7/3/2023 APPLICANT
Assigned to Plan Check Engineer 7/6/2023 JAD BASMA
Corrections Issued 7/9/2023 JAD BASMA
Quality Review Completed 7/19/2023 TEODORO DIAZ RODRIGUEZ
Building Plans Picked Up 7/24/2023 APPLICANT
Applicant returned to address corrections 8/10/2023 JAD BASMA
Plan Check Approved 8/22/2023 JAD BASMA
Issued 10/6/2023 APPLICANT
CofO in Progress 12/3/2024 CHRISTOPHER ROJAS
Permit Finaled 12/24/2024 RUBEN SALAS
CofO Issued 12/24/2024 RUBEN SALAS
Permit Finaled 12/24/2024 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 7/11/2023 DAGOVERTO GUERRERO
Eng Process Fee Ord 176,300 Cleared 7/12/2023 DAGOVERTO GUERRERO
Sewer availability Cleared 7/12/2023 DAGOVERTO GUERRERO
Trees in Parkway Cleared 8/8/2023 ADALBERTO VERA
Low Impact Development (LID) Cleared 8/9/2023 SAMUEL LINN
Permit Cleared 8/9/2023 DAGOVERTO GUERRERO
Roof/Waste drainage to street Cleared 8/9/2023 DAGOVERTO GUERRERO
ZI Cleared 8/10/2023 ALEX VELA
Hydrant and Access approval Cleared 8/15/2023 JOHN CONNEALLY

Contact Information

Contractor Dream Home Design; Lic. No.: 1058115-B 20600 VENTURA BLVD   2355    WOODLAND HILLS, CA 91364

Inspector Information

JAVIER RAMOS JR, (818) 374-1163 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Sewer 10/16/2023 Approved JOHN COLEMAN
Underground Mechanical 10/16/2023 Approved JOHN COLEMAN
Footing/Foundation/Slab 10/27/2023 Corrections Issued ROBERT GOLD
Excavation/Setback/Form/Re-Bar 10/31/2023 Corrections Issued JOHN COLEMAN
Footing/Foundation/Slab 11/3/2023 Approved JOHN COLEMAN
Deputy Reinf. Concrete 11/13/2023 Conditional Approval JUAN VALENZUELA
Floor/Roof Diaphrgm/Shear Wall 11/22/2023 Partial Approval JOHN COLEMAN
Floor/Roof Diaphrgm/Shear Wall 12/18/2023 Corrections Issued KIRK SANDERS
Deputy Wood Construction 12/19/2023 Conditional Approval JUAN VALENZUELA
Floor/Roof Diaphrgm/Shear Wall 12/27/2023 Approved CHRISTOPHE COCHRAN
PLUMBING-Rough 1/4/2024 Partial Approval KIRK SANDERS
BUILDING-Rough-Frame 2/7/2024 Partial Approval KIRK SANDERS
Green Building Rough 2/7/2024 Not Ready for Inspection KIRK SANDERS
HVAC-Rough 2/7/2024 Approved KIRK SANDERS
PLUMBING-Rough 2/7/2024 Approved KIRK SANDERS
Verify Sprinkler Sign Off 2/7/2024 Approved KIRK SANDERS
Shower Pan 2/16/2024 Approved KIRK SANDERS
BUILDING-Rough-Frame 2/21/2024 Corrections Issued KIRK SANDERS
ELECTRICAL-Rough 2/21/2024 Approved KIRK SANDERS
Green Building Rough 2/21/2024 Approved KIRK SANDERS
Interior/Exterior Lathing 2/21/2024 Partial Approval KIRK SANDERS
BUILDING-Rough-Frame 2/28/2024 Corrections Issued KIRK SANDERS
Interior/Exterior Lathing 2/28/2024 Corrections Issued KIRK SANDERS
Insulation 3/4/2024 Partial Approval KIRK SANDERS
Drywall Nailing 3/11/2024 Corrections Issued ROBERTO PALACIOS-LOPEZ
Deputy Steel/Welding 4/29/2024 No Access for Inspection JACK KARGODORIAN
Interior/Exterior Lathing 5/2/2024 Approved CHRISTOPHER ROJAS
Special/Order Compliance 5/31/2024 Corrections Issued CHRISTOPHER ROJAS
Underground Mechanical 6/6/2024 Approved CHRISTOPHER ROJAS
Drywall Nailing 7/1/2024 Partial Approval CHRISTOPHER ROJAS
Structural Steel Frame 7/1/2024 Corrections Issued CHRISTOPHER ROJAS
BUILDING-Rough-Frame 11/20/2024 Approved CHRISTOPHER ROJAS
ELECTRICAL-Final 11/20/2024 Partial Inspection CHRISTOPHER ROJAS
Final 11/20/2024 Partial Inspection CHRISTOPHER ROJAS
Green Building Final 11/20/2024 Approved CHRISTOPHER ROJAS
HVAC-Final 11/20/2024 Partial Inspection CHRISTOPHER ROJAS
PLUMBING-Final 11/20/2024 Corrections Issued CHRISTOPHER ROJAS
SGSOV-Seismic Gas S/O Valve 11/20/2024 SGSOV Approved CHRISTOPHER ROJAS
Service/Power Release 11/20/2024 Not Ready for Inspection CHRISTOPHER ROJAS
Smoke Detectors 11/20/2024 Approved CHRISTOPHER ROJAS
Verify Rec and Parks Fee Memo 11/20/2024 Approved CHRISTOPHER ROJAS
ELECTRICAL-Final 11/22/2024 Partial Inspection CHRISTOPHER ROJAS
Final 11/22/2024 OK to Issue CofO CHRISTOPHER ROJAS
HVAC-Final 11/22/2024 Approved CHRISTOPHER ROJAS
PLUMBING-Final 11/22/2024 Approved CHRISTOPHER ROJAS
Service/Power Release 11/22/2024 Approved CHRISTOPHER ROJAS