3601 S MAY ST 90066
Certificate Information: 3601 S MAY ST 90066
- Application / Permit
- 23010-10000-00989
- Plan Check / Job No.
- B23LA04127
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Recreation Room
- Work Description
- (N) REC ROOM
- Permit Issued
- Issued on 7/10/2023
- Issuing Office
- Current Status
- CofO Issued on 8/30/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/9/2023 | APPLICANT |
| Assigned to Plan Check Engineer | 3/16/2023 | JOE VO |
| Corrections Issued | 3/18/2023 | JOE VO |
| Quality Review Completed | 3/19/2023 | PRANITA SHAH |
| Plan Check Approved | 6/22/2023 | JOE VO |
| Issued | 7/10/2023 | APPLICANT |
| CofO in Progress | 8/27/2024 | JESUS PINEDA |
| CofO in Progress | 8/29/2024 | DAVID FEILER |
| Permit Finaled | 8/30/2024 | RICHARD STEINBACH |
| Permit Finaled | 8/30/2024 | RICHARD STEINBACH |
| CofO Issued | 8/30/2024 | RICHARD STEINBACH |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 4/3/2023 | JASON NG |
| Sewer availability | Cleared | 4/3/2023 | JASON NG |
| Eng Process Fee Ord 176,300 | Cleared | 4/5/2023 | JASON NG |
| Construction near power lines | Cleared | 6/9/2023 | RIDWAN HARDY |
| Grading Pre-Inspection | Cleared | 6/22/2023 | JOE VO |
Contact Information
| Contractor | Gaudenti & Sons Corporation; Lic. No.: 283650-B | 20331 MAIN ST CARSON, CA 90745 |
| Engineer | Wang,, Hongyu; Lic. No.: C72679 | 8887 W FALMINGO RD STE 101 LAS VEGAS, NV 89147 |
Inspector Information
| DAKOTA LOW, (310) 914-3895 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 7/17/2023 | Partial Inspection | HERBERT GIRON |
| Excavation/Setback/Form/Re-Bar | 7/20/2023 | Corrections Issued | JESUS RODRIGUEZ |
| Footing/Foundation/Slab | 7/20/2023 | Corrections Issued | JESUS RODRIGUEZ |
| Sewer | 7/20/2023 | Not Ready for Inspection | JESUS RODRIGUEZ |
| Excavation/Setback/Form/Re-Bar | 7/25/2023 | Not Ready for Inspection | JESUS RODRIGUEZ |
| Footing/Foundation/Slab | 7/25/2023 | Not Ready for Inspection | JESUS RODRIGUEZ |
| PLUMBING-Rough | 7/25/2023 | Partial Approval | JESUS RODRIGUEZ |
| Footing/Foundation/Slab | 8/28/2023 | Partial Approval | JESUS RODRIGUEZ |
| Footing/Foundation/Slab | 9/6/2023 | Approved | JESUS RODRIGUEZ |
| Deputy Wood Construction | 10/19/2023 | Conditional Approval | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 11/1/2023 | Partial Approval | HERBERT GIRON |
| ELECTRICAL-Rough | 1/26/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| HVAC-Rough | 1/26/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| PLUMBING-Rough | 1/26/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| ELECTRICAL-Rough | 1/30/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| HVAC-Rough | 1/30/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| PLUMBING-Rough | 1/30/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 2/6/2024 | Corrections Issued | JESUS RODRIGUEZ |
| ELECTRICAL-Rough | 2/6/2024 | Approved | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 2/6/2024 | Approved | JESUS RODRIGUEZ |
| HVAC-Rough | 2/6/2024 | Not Ready for Inspection | JESUS RODRIGUEZ |
| PLUMBING-Rough | 2/6/2024 | Corrections Issued | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 2/8/2024 | Corrections Issued | JESUS RODRIGUEZ |
| ELECTRICAL-Rough | 2/8/2024 | Approved | JESUS RODRIGUEZ |
| HVAC-Rough | 2/8/2024 | Approved | JESUS RODRIGUEZ |
| PLUMBING-Rough | 2/8/2024 | Approved | JESUS RODRIGUEZ |
| Insulation | 2/12/2024 | Not Ready for Inspection | HERBERT GIRON |
| Insulation | 2/23/2024 | Approved | JESUS RODRIGUEZ |
| Drywall Nailing | 2/28/2024 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 7/16/2024 | Approved | JESUS RODRIGUEZ |
| Verify Sprinkler Sign Off | 7/16/2024 | Approved | JESUS RODRIGUEZ |
| ELECTRICAL-Final | 7/24/2024 | Corrections Issued | JESUS RODRIGUEZ |
| ELECTRICAL-Final | 8/22/2024 | Approved | HERBERT GIRON |
| Final | 8/23/2024 | Partial Approval | JESUS PINEDA |
| PLUMBING-Final | 8/23/2024 | Approved | JESUS PINEDA |
| SGSOV-Seismic Gas S/O Valve | 8/23/2024 | SGSOV Not Required | JESUS PINEDA |
| Service/Power Release | 8/23/2024 | Approved | JESUS PINEDA |
| Smoke Detectors | 8/23/2024 | Approved | JESUS PINEDA |
| Final | 8/27/2024 | OK to Issue CofO | JESUS PINEDA |