4226 N STERN AVE 91423
Certificate Information: 4226 N STERN AVE 91423
- Application / Permit
- 22047-20000-01724
- Plan Check / Job No.
- B22VN12739
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 24'-6" X 13'-6" SWIMMING POOL WITH ATTACHED 6' X 6' SPA PER LA CITY STANDARD PLAN #268 AND ENGINEERED DETAIL #551
- Permit Issued
- Issued on 10/25/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 5/11/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/19/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/19/2022 | GURUNATH NESARAJAH |
| Corrections Issued | 8/19/2022 | GURUNATH NESARAJAH |
| Applicant returned to address corrections | 9/6/2022 | DANIEL ABRAMYAN |
| Issued | 10/25/2022 | APPLICANT |
| CofO in Progress | 5/11/2023 | MATTHEW NELSON |
| Permit Finaled | 5/11/2023 | MICHAEL SMITH |
| CofO Issued | 5/11/2023 | MICHAEL SMITH |
| Permit Finaled | 5/11/2023 | MICHAEL SMITH |
Permit Application Clearance Information
| Construction near power lines | Cleared | 10/14/2022 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| MISAEL ESPARZA, (818) 374-1169 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 12/14/2022 | Corrections Issued | MISAEL ESPARZA |
| Pool Piping | 12/14/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| Pre-Gunite | 12/14/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| Rough-Plumbing | 12/14/2022 | Not Ready for Inspection | MISAEL ESPARZA |
| Pre-Gunite | 12/20/2022 | Approved | MISAEL ESPARZA |
| Deputy Shotcrete | 12/23/2022 | Conditional Approval | DAVID MATSON |
| Gas Piping or Gas Test | 12/27/2022 | Approved | MISAEL ESPARZA |
| Gunite | 12/27/2022 | Approved | MISAEL ESPARZA |
| Rough-Electrical | 12/27/2022 | Approved | MISAEL ESPARZA |
| Rough-Plumbing | 12/27/2022 | Approved | MISAEL ESPARZA |
| Grounding or Bonding | 1/4/2023 | Approved | MISAEL ESPARZA |
| Enclosure/Fence | 1/19/2023 | Corrections Issued | MISAEL ESPARZA |
| Enclosure/Fence | 1/23/2023 | Approved | MISAEL ESPARZA |
| ELECTRICAL-Final | 1/27/2023 | Approved | MISAEL ESPARZA |
| Excavation/Setback/Form/Re-Bar | 1/27/2023 | Approved | MISAEL ESPARZA |
| Final | 1/27/2023 | Corrections Issued | MISAEL ESPARZA |
| PLUMBING-Final | 1/27/2023 | Corrections Issued | MISAEL ESPARZA |
| Pool Equipment Noise Test | 1/27/2023 | Approved | FELIPE PENICHE |
| SGSOV-Seismic Gas S/O Valve | 1/27/2023 | SGSOV Not Ready | MISAEL ESPARZA |
| Final | 4/3/2023 | Corrections Issued | THOMAS FINNILA |
| SGSOV-Seismic Gas S/O Valve | 4/3/2023 | SGSOV Not Ready | THOMAS FINNILA |
| Final | 5/10/2023 | OK to Issue CofO | MATTHEW NELSON |
| Rough-Plumbing | 5/10/2023 | Approved | MATTHEW NELSON |
| SGSOV-Seismic Gas S/O Valve | 5/10/2023 | SGSOV Approved | MATTHEW NELSON |