400 S SALTAIR AVE 90049
Certificate Information: 400 S SALTAIR AVE 90049
- Application / Permit
- 22047-20000-00438
- Plan Check / Job No.
- B22VN03293
- Group
- Building
- Type
- Swimming-Pool/Spa
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (20) Pool/Spa - Private
- Work Description
- NEW 18' X 44' POOL PER STANDARD PLAN #268 AND SUPPLEMENTAL DETAIL
- Permit Issued
- Issued on 10/25/2022
- Issuing Office
- Current Status
- CofO Issued on 12/3/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/3/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 3/4/2022 | RAPHAEL ROSAS |
| Corrections Issued | 3/4/2022 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 4/3/2022 | RAPHAEL ROSAS |
| Applicant returned to address corrections | 4/16/2022 | RAPHAEL ROSAS |
| Building Plans Picked Up | 4/19/2022 | APPLICANT |
| Issued | 10/25/2022 | APPLICANT |
| CofO in Progress | 11/27/2024 | KENNETH NAGLE |
| CofO in Progress | 11/27/2024 | KENNETH NAGLE |
| CofO in Progress | 11/27/2024 | KENNETH NAGLE |
| Permit Finaled | 12/3/2024 | RICHARD STEINBACH |
| CofO Issued | 12/3/2024 | RICHARD STEINBACH |
| Permit Finaled | 12/3/2024 | RICHARD STEINBACH |
Permit Application Clearance Information
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| ZA Case | Cleared | 3/8/2022 | MIGUEL GAMBOA |
| Grading Pre-Inspection | Cleared | 4/3/2022 | RAPHAEL ROSAS |
Contact Information
| Contractor | Marten Darin Construction Company; Lic. No.: 525472-C53 | P O BOX 659 PACIFIC PALISADES, CA 90272 |
| Engineer | Biedenbach,, Christopher James; Lic. No.: C74003 | 1201 N TUSTIN AVE ANAHEIM, CA 92807 |
Inspector Information
| HERBERT GIRON, (310) 914-3891 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Gas Piping or Gas Test | 4/20/2023 | Conditional Approval | JESUS PINEDA |
| Rough-Plumbing | 4/20/2023 | Conditional Approval | JESUS PINEDA |
| FLOOD-Proofing Certificate | 5/15/2023 | Approved | CARLOS MATAMOROS |
| Pool Piping | 5/15/2023 | Approved | CARLOS MATAMOROS |
| Pre-Gunite | 5/15/2023 | Approved | CARLOS MATAMOROS |
| Deck | 6/28/2023 | Approved | CARLOS MATAMOROS |
| Enclosure/Fence | 8/4/2023 | Approved | CARLOS MATAMOROS |
| Pool Equipment Noise Test | 10/22/2024 | Approved | EUSEBIO GUZMAN |
| Excavation/Setback/Form/Re-Bar | 10/25/2024 | Approved | CARLOS MATAMOROS |
| Final | 10/25/2024 | Not Ready for Inspection | CARLOS MATAMOROS |
| SGSOV-Seismic Gas S/O Valve | 10/25/2024 | SGSOV Not Ready | CARLOS MATAMOROS |
| ELECTRICAL-Final | 11/18/2024 | Approved | JESUS RODRIGUEZ |
| Final | 11/18/2024 | OK to Issue CofO | JESUS RODRIGUEZ |
| SGSOV-Seismic Gas S/O Valve | 11/18/2024 | SGSOV Approved | JESUS RODRIGUEZ |