20524 W LASSEN ST 91311

Certificate Information: 20524 W LASSEN ST 91311

Application / Permit
22047-10000-00165
Plan Check / Job No.
B22LA01417
Group
Building
Type
Swimming-Pool/Spa
Sub-Type
Commercial
Primary Use
(4) Pool/Spa - Public
Work Description
NEW HOTEL PUBLIC SWIMMING POOL 15' X 40'.
Permit Issued
Issued on 1/10/2023
Issuing Office
Current Status
CofO Issued on 3/19/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 1/27/2022 APPLICANT
Assigned to Plan Check Engineer 2/17/2022 ARMEN JIVALAGIAN
Corrections Issued 2/24/2022 ARMEN JIVALAGIAN
Quality Review Completed 3/2/2022 PETER KIM
Disabled Access Plans Picked Up 3/16/2022 APPLICANT
Building Plans Picked Up 3/18/2022 APPLICANT
Applicant returned to address corrections 12/27/2022 ARMEN JIVALAGIAN
Plan Check Approved 1/6/2023 ARMEN JIVALAGIAN
Issued 1/10/2023 APPLICANT
CofO in Progress 3/19/2024 JEFFREY DURAN
Permit Finaled 3/19/2024 JEFFREY DURAN
CofO Issued 3/19/2024 JEFFREY DURAN
Permit Finaled 3/19/2024 JEFFREY DURAN

Permit Application Clearance Information

Address approval Cleared 8/24/2022 CARLOS AGUILERA
Roof/Waste drainage to street Cleared 8/24/2022 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 8/25/2022 CARLOS AGUILERA
"D" conditions Cleared 8/30/2022 DALIA MOKAYED
"Q" conditions Cleared 8/30/2022 DALIA MOKAYED
Miscellaneous Cleared 8/30/2022 DALIA MOKAYED
Tract Map conditions Cleared 8/30/2022 DALIA MOKAYED
ZA Case Cleared 8/30/2022 DALIA MOKAYED
ZA Case Cleared 8/30/2022 DALIA MOKAYED
Excavation more than 5-ft deep Cleared 9/6/2022 CALOSHA APPROVED
DAS Clearance Cleared 9/26/2022 ARMEN JIVALAGIAN
CPC Cleared 9/27/2022 DALIA MOKAYED
Sewer availability Cleared 10/7/2022 ABDULLAH SADOZAI
Public Swimming Pool approval Cleared 12/27/2022 LACDHS APPROVED

Contact Information

Contractor Bodar Enterprises; Lic. No.: 536360-B P O BOX 892110      TEMECULA, CA 92589
Engineer Lacher,, Todd Lee; Lic. No.: C67656 1201 N TUSTIN AVE      ANAHEIM, CA 92807
Engineer Pelayo,, Jorge A; Lic. No.: C91269 1102 VINTAGE CIRCLE      CORONA, CA 92881

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 1/26/2023 Not Ready for Inspection JEFFREY FULTON
Grounding or Bonding 1/26/2023 Not Ready for Inspection JEFFREY FULTON
Pre-Gunite 1/26/2023 Not Ready for Inspection JEFFREY FULTON
Rough-Electrical 1/26/2023 Not Ready for Inspection JEFFREY FULTON
Rough-Plumbing 1/26/2023 Not Ready for Inspection JEFFREY FULTON
Pre-Gunite 3/20/2023 Partial Inspection DEANDRE HOFFMAN
Excavation/Setback/Form/Re-Bar 3/24/2023 Approved JEFFREY FULTON
Grounding or Bonding 3/24/2023 Approved JEFFREY FULTON
Pre-Gunite 3/24/2023 Approved JEFFREY FULTON
Deputy Shotcrete 3/28/2023 Conditional Approval DEANDRE HOFFMAN
Deck 4/12/2023 Partial Inspection JEFFREY FULTON
Grounding or Bonding 4/12/2023 Not Ready for Inspection JEFFREY FULTON
ELECTRICAL-Final 10/10/2023 Approved JEFFREY FULTON
Final 10/10/2023 Conditional Approval JEFFREY FULTON
PLUMBING-Final 10/10/2023 Approved JEFFREY FULTON
SGSOV-Seismic Gas S/O Valve 10/10/2023 SGSOV Approved JEFFREY FULTON
Special/Order Compliance 10/10/2023 Approved JEFFREY FULTON
Final 10/26/2023 Not Ready for Inspection JEFFREY FULTON
Final 3/19/2024 OK to Issue CofO JEFFREY DURAN