17016-17018 W COTTER PL 91436
Certificate Information: 17016-17018 W COTTER PL 91436
- Application / Permit
- 22020-10000-02327
- Plan Check / Job No.
- B22LA18902
- Group
- Building
- Type
- Nonbldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (23) Retaining Wall
- Work Description
- ePlan - NEW (2) SITE RETAINING WALLS WITH SHORING
- Permit Issued
- Issued on 12/18/2024
- Issuing Office
- Current Status
- Issued on 12/18/2024
Permit Application Status History
| Submitted | 9/20/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 9/22/2022 | STARR CHEN |
| Corrections Issued | 9/25/2022 | STARR CHEN |
| Quality Review Completed | 9/28/2022 | EUGENE BARBEAU |
| Applicant returned to address corrections | 5/4/2023 | STARR CHEN |
| Applicant returned to address corrections | 5/5/2023 | STARR CHEN |
| Applicant returned to address corrections | 7/24/2023 | STARR CHEN |
| Applicant returned to address corrections | 8/11/2023 | STARR CHEN |
| Applicant returned to address corrections | 8/24/2023 | STARR CHEN |
| Applicant returned to address corrections | 7/17/2024 | STARR CHEN |
| Applicant returned to address corrections | 9/25/2024 | STARR CHEN |
| Plan Check Approved | 12/12/2024 | STARR CHEN |
| Issued | 12/18/2024 | APPLICANT |
Permit Application Clearance Information
| Landscape for retaining wall | Cleared | 3/6/2023 | MIGUEL GAMBOA |
| GPI Written Notices | Cleared | 12/12/2024 | STARR CHEN |
| Grading Pre-Inspection | Cleared | 12/12/2024 | STARR CHEN |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Danz,, Joshua; Lic. No.: C84764 | 1164 ELDERBERRY CIRCLE FOLSOM, CA 95630 |
| Engineer | De, Leon, Cynthia Aguilar; Lic. No.: C31604 | 347 ROBERTSON BLVD BEVERLY HILLS, CA 90211 |
| Engineer | Yuzon,, Benigno Sari; Lic. No.: S3454 | 2511 PEACHWOOD PLACE WESTLAKE VILLAGE, CA 91361 |
| Geologist | Feffer,, Joshua R; Lic. No.: EG2138 | 12253 GORHAM AVE LOS ANGELES, CA 90049 |
Inspector Information
| MANUEL TEJADA, (818) 374-4339 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Piling/Pier/Caisson | 1/31/2025 | Partial Approval | ROBERT PINA |
| Deputy Reinf. Concrete | 2/3/2025 | Approved | ROBERT PINA |
| Deputy Reinf. Concrete | 2/5/2025 | Approved | ROBERT PINA |
| Piling/Pier/Caisson | 2/5/2025 | Approved | ROBERT PINA |
| Deputy Reinf. Concrete | 3/5/2025 | No Access for Inspection | ROBERT PINA |
| Excavation/Setback/Form/Re-Bar | 3/6/2025 | Approved | ROBERT PINA |
| Deputy Shotcrete | 3/7/2025 | Approved | ROBERT PINA |
| Deputy Other (see comments) | 3/20/2025 | Approved | ROBERT PINA |
| Deputy Reinf. Concrete | 6/24/2025 | Approved | MANUEL TEJADA |