2918 S MAPLE AVE 1-4 90011
Certificate Information: 2918 S MAPLE AVE 1-4 90011
- Application / Permit
- 22016-20000-39044
- Plan Check / Job No.
- B22VN19027
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- CONVERT ATTACHED GARAGE INTO ACCESSORY DWELLING UNIT, PER GCS 65852.2(e)(1)(C) FOR EX. 3-UNIT APARTMENT.
- Permit Issued
- Issued on 7/12/2023
- Issuing Office
- Current Status
- Issued on 7/12/2023
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/27/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 12/29/2022 | LUIS RINCON |
| Corrections Issued | 12/30/2022 | LUIS RINCON |
| Building Plans Picked Up | 2/15/2023 | APPLICANT |
| Applicant returned to address corrections | 3/13/2023 | MIROOSH KHACHATOORIAN |
| Disabled Access Plans Picked Up | 3/15/2023 | APPLICANT |
| Plan Check Approved | 7/12/2023 | ROSENDO MEDINA |
| Issued | 7/12/2023 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 3/20/2023 | CELINA MORENO |
| Sewer availability | Cleared | 3/20/2023 | CELINA MORENO |
| Eng Process Fee Ord 176,300 | Cleared | 3/21/2023 | CELINA MORENO |
| DAS Clearance | Cleared | 7/12/2023 | LUIS RINCON |
Contact Information
| Contractor | 1 Smart Build Inc; Lic. No.: 1076428-B | 21243 VENTURA BLVD UNIT 133 WOODLAND HILLS, CA 91364 |
| Engineer | Standley,, Craig Erick; Lic. No.: C87675 | 60 VIA CARATAMA SAN CLEMENTE, CA 92673 |
Inspector Information
| PAUL BAZERKANIAN, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| LUIS CCAMACHO, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
| ALAN MORELOS, (213) 482-0353 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Green Building Rough | 10/14/2025 | Not Ready for Inspection | ALFREDO LOPEZ |
| Wood Frame | 10/14/2025 | Not Ready for Inspection | ALFREDO LOPEZ |
| Insulation | 10/24/2025 | Partial Approval | ALFREDO LOPEZ |
| Floor/Roof Diaphrgm/Shear Wall | 12/1/2025 | Partial Approval | LARRY ARNICK |
| Final | 3/2/2026 | Not Ready for Inspection | ALFREDO LOPEZ |
| Green Building Final | 3/2/2026 | Not Ready for Inspection | ALFREDO LOPEZ |
| Green Building Rough | 3/2/2026 | Not Ready for Inspection | ALFREDO LOPEZ |
| SGSOV-Seismic Gas S/O Valve | 3/2/2026 | SGSOV Not Ready | ALFREDO LOPEZ |
| Smoke Detectors | 3/2/2026 | Not Ready for Inspection | ALFREDO LOPEZ |
| Wood Frame | 3/2/2026 | Not Ready for Inspection | ALFREDO LOPEZ |
| Final | 4/10/2026 | Not Ready for Inspection | REGINA MENDEZ |
| Green Building Final | 4/10/2026 | Not Ready for Inspection | REGINA MENDEZ |
| Green Building Rough | 4/10/2026 | Not Ready for Inspection | REGINA MENDEZ |
| SGSOV-Seismic Gas S/O Valve | 4/10/2026 | SGSOV Not Ready | REGINA MENDEZ |
| Smoke Detectors | 4/10/2026 | Not Ready for Inspection | REGINA MENDEZ |
| Wood Frame | 4/10/2026 | Not Ready for Inspection | REGINA MENDEZ |