2313 N BANYAN DR 90049
Certificate Information: 2313 N BANYAN DR 90049
- Application / Permit
- 22016-20000-24987
- Plan Check / Job No.
- B22VN12677
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- FIRE DAMAGE REPAIRS TO THE WALL AT THE ATTACHED GARAGE. INTERIOR REMODEL TO ADD (2) NEW KITCHEN WINDOWS IN DIFFERENT LOCATIONS AND ENCLOSE (2) EXISTING WINDOWS. INTERIOR REMODEL TO CREATE A NEW BATHROOM DOWNSTAIRS, CONVERT UPSTAIRS CLOSET TO A FULL BATHROOM, CONVERT A PORTION OF THE GARAGE INTO A STORAGE ROOM, AND PERFORM A LIKE FOR LIKE CHANGEOUT OF THE REST OF THE EXISTING WINDOWS AND DOORS. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 11/18/2022
- Issuing Office
- Valley
- Current Status
- Permit Finaled on 7/21/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/18/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/18/2022 | LUISANGEL VALENZUELA |
| Corrections Issued | 8/18/2022 | LUISANGEL VALENZUELA |
| Applicant returned to address corrections | 9/7/2022 | JESSE ARELLANO |
| Plan Check Approved | 11/18/2022 | ANTOAN MISHRIKI |
| Issued | 11/18/2022 | APPLICANT |
| Permit Finaled-Status Void | 6/12/2025 | KEVIN SARGSYAN |
| Re-Activate Permit | 7/21/2025 | KEVIN SARGSYAN |
| Permit Finaled | 7/21/2025 | KENNETH NAGLE |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 8/23/2022 | KIRK LINKLATER |
Contact Information
| Contractor | Tri Tech Restoration & Construction Co Inc; Lic. No.: 501801-B | 3301 N SAN FERNANDO BLVD BURBANK, CA 91504 |
Inspector Information
| KEVIN SARGSYAN, (310) 914-3889 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 4/6/2023 | Conditional Approval | MICHAEL PELHAM |
| Footing/Foundation/Slab | 4/7/2023 | Partial Approval | KEVIN SARGSYAN |
| PLUMBING-Rough | 8/11/2023 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Rough | 8/15/2023 | Partial Approval | KEVIN SARGSYAN |
| Deputy Drilled-In Anchors | 8/29/2023 | Approved | KEVIN SARGSYAN |
| Excavation/Setback/Form/Re-Bar | 8/29/2023 | Approved | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 3/8/2024 | Corrections Issued | KEVIN SARGSYAN |
| HVAC-Rough | 3/11/2024 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Rough | 3/15/2024 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 3/19/2024 | Approved | KEVIN SARGSYAN |
| PLUMBING-Rough | 3/19/2024 | Approved | KEVIN SARGSYAN |
| HVAC-Rough | 4/5/2024 | Conditional Approval | KEVIN SARGSYAN |
| Shower Pan | 4/5/2024 | Approved | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 4/22/2024 | Partial Approval | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 4/25/2024 | Corrections Issued | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 4/25/2024 | Approved | KEVIN SARGSYAN |
| BUILDING-Rough-Frame | 4/29/2024 | Approved | KEVIN SARGSYAN |
| Insulation | 5/1/2024 | Corrections Issued | KEVIN SARGSYAN |
| Insulation | 5/3/2024 | Approved | KEVIN SARGSYAN |
| Drywall Nailing | 5/9/2024 | Not Ready for Inspection | KEVIN SARGSYAN |
| Drywall Nailing | 5/10/2024 | Approved | KEVIN SARGSYAN |
| ELECTRICAL-Final | 8/28/2024 | Corrections Issued | KEVIN SARGSYAN |
| Final | 8/28/2024 | Corrections Issued | KEVIN SARGSYAN |
| HVAC-Final | 8/28/2024 | Corrections Issued | KEVIN SARGSYAN |
| PLUMBING-Final | 8/28/2024 | Corrections Issued | KEVIN SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 8/28/2024 | SGSOV Not Ready | KEVIN SARGSYAN |
| Smoke Detectors | 8/28/2024 | Corrections Issued | KEVIN SARGSYAN |
| ELECTRICAL-Final | 6/12/2025 | Approved | KEVIN SARGSYAN |
| Final | 6/12/2025 | Conditional Approval | KEVIN SARGSYAN |
| HVAC-Final | 6/12/2025 | Approved | KEVIN SARGSYAN |
| PLUMBING-Final | 6/12/2025 | Approved | KEVIN SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 6/12/2025 | SGSOV Approved | KEVIN SARGSYAN |
| Smoke Detectors | 6/12/2025 | Approved | KEVIN SARGSYAN |