9750 N CASABA AVE 91311
Certificate Information: 9750 N CASABA AVE 91311
- Application / Permit
- 22016-20000-22362
- Plan Check / Job No.
- B22VN11491
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- eplan CONVERT (E) DETACHED GARAGE INTO ACCESSORY DWELLING UNIT PER ORDINANCE.
- Permit Issued
- Issued on 8/11/2022
- Issuing Office
- Current Status
- CofO Issued on 12/27/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/26/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 7/29/2022 | FARSHAD ALIMOHAMADI |
| Corrections Issued | 7/30/2022 | FARSHAD ALIMOHAMADI |
| Plan Check Approved | 8/11/2022 | FARSHAD ALIMOHAMADI |
| Issued | 8/11/2022 | APPLICANT |
| CofO in Progress | 12/21/2022 | DAVID SCANTLIN |
| CofO Issued | 12/27/2022 | MICHAEL SMITH |
| Permit Finaled | 12/27/2022 | MICHAEL SMITH |
Permit Application Clearance Information
| Address approval | Cleared | 8/1/2022 | ROMAN GUTIERREZ |
| Eng Process Fee Ord 176,300 | Cleared | 8/1/2022 | ROMAN GUTIERREZ |
| Sewer availability | Cleared | 8/1/2022 | ROMAN GUTIERREZ |
| Construction near power lines | Cleared | 8/10/2022 | RIDWAN HARDY |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JACK KARGODORIAN, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
| KRISTEN CAUSEY, (818) 774-4319 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 8/24/2022 | Partial Approval | JEFFREY PARD |
| Footing/Foundation/Slab | 8/30/2022 | Not Ready for Inspection | JEFFREY PARD |
| Deputy Drilled-In Anchors | 8/31/2022 | Approved | JEFFREY PARD |
| PLUMBING-Rough | 9/1/2022 | Partial Approval | DAVID SCANTLIN |
| BUILDING-Rough-Frame | 9/7/2022 | Not Ready for Inspection | JEFFREY PARD |
| ELECTRICAL-Rough | 9/7/2022 | Corrections Issued | JEFFREY PARD |
| HVAC-Rough | 9/7/2022 | Not Ready for Inspection | JEFFREY PARD |
| Floor/Roof Diaphrgm/Shear Wall | 9/12/2022 | Approved | SEAN WIRCH |
| PLUMBING-Rough | 9/12/2022 | Approved | SEAN WIRCH |
| HVAC-Rough | 9/19/2022 | Corrections Issued | JUSTIN HAWLEY |
| Interior/Exterior Lathing | 9/19/2022 | Partial Approval | JUSTIN HAWLEY |
| BUILDING-Rough-Frame | 10/4/2022 | Approved | DAVID SCANTLIN |
| ELECTRICAL-Rough | 10/4/2022 | Approved | DAVID SCANTLIN |
| Green Building Rough | 10/4/2022 | Approved | DAVID SCANTLIN |
| HVAC-Rough | 10/4/2022 | Approved | DAVID SCANTLIN |
| Insulation | 10/14/2022 | Approved | KRISTEN CAUSEY |
| Shower Pan | 10/14/2022 | Approved | KRISTEN CAUSEY |
| Drywall Nailing | 10/24/2022 | Approved | DAVID SCANTLIN |
| Interior/Exterior Lathing | 10/24/2022 | Approved | DAVID SCANTLIN |
| ELECTRICAL-Final | 12/20/2022 | Approved | DAVID SCANTLIN |
| Final | 12/20/2022 | OK to Issue CofO | DAVID SCANTLIN |
| HVAC-Final | 12/20/2022 | Approved | DAVID SCANTLIN |
| PLUMBING-Final | 12/20/2022 | Approved | DAVID SCANTLIN |
| SGSOV-Seismic Gas S/O Valve | 12/20/2022 | SGSOV Approved | DAVID SCANTLIN |
| Smoke Detectors | 12/20/2022 | Approved | DAVID SCANTLIN |