660 W 120TH ST 90044
Certificate Information: 660 W 120TH ST 90044
- Application / Permit
- 22016-20000-21639
- Plan Check / Job No.
- B22VN11186
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT DETACHED GARAGE TO ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d)
- Permit Issued
- Issued on 10/21/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 6/24/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/28/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/2/2022 | JEROME MAGAT PALMA |
| Corrections Issued | 8/2/2022 | JEROME MAGAT PALMA |
| Building Plans Picked Up | 8/3/2022 | APPLICANT |
| Plan Check Approved | 10/20/2022 | ALEC MOUSAKHANIAN |
| Issued | 10/21/2022 | APPLICANT |
| CofO in Progress | 6/24/2025 | JOHN KLARIN |
| CofO Issued | 6/24/2025 | ANSON MAGLASANG |
| Permit Finaled | 6/24/2025 | ANSON MAGLASANG |
Permit Application Clearance Information
| Address approval | Cleared | 8/24/2022 | JOSE HERNANDEZ |
| Sewer availability | Cleared | 8/24/2022 | JOSE HERNANDEZ |
| Eng Process Fee Ord 176,300 | Cleared | 8/25/2022 | JOSE HERNANDEZ |
| Miscellaneous | Cleared | 8/25/2022 | NATHAN ROMINE |
| ZA Case | Cleared | 8/25/2022 | NATHAN ROMINE |
Contact Information
| No Data Available. |
Inspector Information
| BEN MOLSTAD, (310) 732-4557 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 12/1/2022 | Corrections Issued | ALIZAH MAYAGOITIA |
| ELECTRICAL-Rough | 10/26/2023 | Corrections Issued | JAMES CHAVEZ |
| ELECTRICAL-Rough | 11/29/2023 | Corrections Issued | JAMES CHAVEZ |
| HVAC-Rough | 11/29/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| PLUMBING-Rough | 11/29/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| Wood Frame | 11/29/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| BUILDING-Rough-Frame | 12/1/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| ELECTRICAL-Rough | 12/1/2023 | Corrections Issued | JAMES CHAVEZ |
| Green Building Rough | 12/1/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| HVAC-Rough | 12/1/2023 | Corrections Issued | JAMES CHAVEZ |
| METHANE-Rough | 12/1/2023 | Approved | JAMES CHAVEZ |
| PLUMBING-Rough | 12/1/2023 | Corrections Issued | JAMES CHAVEZ |
| Wood Frame | 12/1/2023 | Partial Approval | JAMES CHAVEZ |
| BUILDING-Rough-Frame | 12/28/2023 | Not Ready for Inspection | JOHN KLARIN |
| ELECTRICAL-Rough | 12/28/2023 | Not Ready for Inspection | JOHN KLARIN |
| Footing/Foundation/Slab | 12/28/2023 | Approved | JOHN KLARIN |
| Green Building Rough | 12/28/2023 | Not Ready for Inspection | JOHN KLARIN |
| HVAC-Rough | 12/28/2023 | Not Ready for Inspection | JOHN KLARIN |
| PLUMBING-Rough | 12/28/2023 | Not Ready for Inspection | JOHN KLARIN |
| Rough-Elec/Plmb/HVAC | 1/12/2024 | Corrections Issued | JOHN KLARIN |
| ELECTRICAL-Rough | 1/17/2024 | Corrections Issued | JAMES CHAVEZ |
| BUILDING-Rough-Frame | 1/22/2024 | Approved | JAMES CHAVEZ |
| ELECTRICAL-Rough | 1/22/2024 | Approved | JAMES CHAVEZ |
| Green Building Rough | 1/22/2024 | Approved | JAMES CHAVEZ |
| HVAC-Rough | 1/22/2024 | Approved | JAMES CHAVEZ |
| Insulation | 1/22/2024 | Approved | JAMES CHAVEZ |
| PLUMBING-Rough | 1/22/2024 | Approved | JAMES CHAVEZ |
| Drywall Nailing | 1/26/2024 | Corrections Issued | JAMES CHAVEZ |
| Drywall Nailing | 1/31/2024 | Approved | JAMES CHAVEZ |
| Interior/Exterior Lathing | 1/31/2024 | Partial Approval | JAMES CHAVEZ |
| Interior/Exterior Lathing | 2/16/2024 | Partial Approval | JAMES CHAVEZ |
| Shower Pan | 2/22/2024 | Corrections Issued | JAMES CHAVEZ |
| Shower Pan | 2/23/2024 | Approved | JAMES CHAVEZ |
| Green Building Final | 3/11/2024 | Not Ready for Inspection | JAMES CHAVEZ |
| Sewer | 3/11/2024 | Corrections Issued | JAMES CHAVEZ |
| Smoke Detectors | 3/11/2024 | Not Ready for Inspection | JAMES CHAVEZ |
| Special/Order Compliance | 3/11/2024 | Corrections Issued | JAMES CHAVEZ |
| Underground Mechanical | 3/11/2024 | Partial Approval | JAMES CHAVEZ |
| Final | 3/15/2024 | Corrections Issued | JAMES CHAVEZ |
| Green Building Final | 3/15/2024 | Not Ready for Inspection | JAMES CHAVEZ |
| SGSOV-Seismic Gas S/O Valve | 3/15/2024 | SGSOV Not Ready | JAMES CHAVEZ |
| Smoke Detectors | 3/15/2024 | Approved | JAMES CHAVEZ |
| Final | 4/7/2025 | Corrections Issued | BEN MOLSTAD |
| Green Building Final | 4/7/2025 | Not Ready for Inspection | BEN MOLSTAD |
| SGSOV-Seismic Gas S/O Valve | 4/7/2025 | SGSOV Not Ready | BEN MOLSTAD |
| Final | 4/16/2025 | No Access for Inspection | BEN MOLSTAD |
| Green Building Final | 4/16/2025 | Corrections Issued | BEN MOLSTAD |
| SGSOV-Seismic Gas S/O Valve | 4/16/2025 | SGSOV Not Ready | BEN MOLSTAD |
| SGSOV-Seismic Gas S/O Valve | 5/5/2025 | SGSOV Not Ready | BEN MOLSTAD |
| SGSOV-Seismic Gas S/O Valve | 5/23/2025 | SGSOV Not Ready | BEN MOLSTAD |
| Pre-Inspection | 5/27/2025 | Approved | JOHN KLARIN |
| Final | 6/24/2025 | OK to Issue CofO | JOHN KLARIN |
| Green Building Final | 6/24/2025 | Approved | JOHN KLARIN |
| SGSOV-Seismic Gas S/O Valve | 6/24/2025 | SGSOV Approved | JOHN KLARIN |