20121 W DEVONSHIRE ST 91311
Certificate Information: 20121 W DEVONSHIRE ST 91311
- Application / Permit
- 22016-20000-19259
- Plan Check / Job No.
- B22VN10016
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (15) Telecommunication Transmitter - wireless
- Work Description
- Scope of Work - Install (6) proposed panel antennas (2 per sector) - Install (12) proposed RRUs (4 per sector) - Install (3) proposed surge suppression device (1 per sector) - Install (3) proposed hybrid cables ( 1 per sector) - Install proposed jumpers from RRU to antennas required Equipment Scope of Work - Install 6' tall 10 x 10' chain link equipment enclosure - Install cable icebridge - Install (1) proposed equipment cabinet - Install (1) proposed utility H-Frame - Install (1) proposed power conduit - Install (1) proposed telco conduit - Install (1) proposed NEMA 3 telco-fiber box - Install (1) proposed GPS Antenna - Install camlock gen lug intersect at ground level - Install (1) electrical meter
- Permit Issued
- Issued on 12/13/2022
- Issuing Office
- Current Status
- Permit Finaled on 10/5/2023
Permit Application Status History
| Submitted | 7/28/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 7/29/2022 | ADAM HEGAZI |
| Corrections Issued | 8/1/2022 | ADAM HEGAZI |
| Plan Check Approved | 11/20/2022 | HERNAN ARREOLA |
| Issued | 12/13/2022 | APPLICANT |
| Permit Finaled | 10/4/2023 | DEANDRE HOFFMAN |
Permit Application Clearance Information
| Plan Approval | Cleared | 10/18/2022 | KATHERINE RICE |
| ZA Case | Cleared | 10/18/2022 | KATHERINE RICE |
Contact Information
| Contractor | Tristrux Llc; Lic. No.: 1092734-B | 473 US HIGHWAY 46 CLIFTON, NJ 07011 |
| Engineer | Connell,, Daniel Michael; Lic. No.: NA62543 | , |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 7/14/2023 | Partial Inspection | DEANDRE HOFFMAN |
| Excavation/Setback/Form/Re-Bar | 7/28/2023 | Corrections Issued | DEANDRE HOFFMAN |
| Excavation/Setback/Form/Re-Bar | 8/4/2023 | Not Ready for Inspection | CAMERON CHABAN |
| Excavation/Setback/Form/Re-Bar | 8/17/2023 | Partial Inspection | DEANDRE HOFFMAN |
| Final | 10/4/2023 | Permit Finaled | DEANDRE HOFFMAN |
| SGSOV-Seismic Gas S/O Valve | 10/4/2023 | SGSOV Approved | DEANDRE HOFFMAN |
| Smoke Detectors | 10/4/2023 | Approved | DEANDRE HOFFMAN |