7540 N COZYCROFT AVE 91306
Certificate Information: 7540 N COZYCROFT AVE 91306
- Application / Permit
- 22016-20000-09572
- Plan Check / Job No.
- B22VN04652
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT (E) GARAGE TO ADU PER STATE LAW (1-STORY)
- Permit Issued
- Issued on 5/25/2022
- Issuing Office
- Current Status
- CofO Issued on 8/22/2022
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/29/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 3/30/2022 | CARLOS MONTES |
| Corrections Issued | 3/31/2022 | CARLOS MONTES |
| Plan Check Approved | 5/25/2022 | CARLOS MONTES |
| Issued | 5/25/2022 | APPLICANT |
| CofO in Progress | 8/19/2022 | STEVEN BACK |
| Permit Finaled | 8/22/2022 | JOHN JANSON |
| CofO Issued | 8/22/2022 | JOHN JANSON |
| Permit Finaled | 8/22/2022 | JOHN JANSON |
Permit Application Clearance Information
| Address approval | Cleared | 4/5/2022 | DAGOVERTO GUERRERO |
| Sewer availability | Cleared | 4/5/2022 | DAGOVERTO GUERRERO |
| Eng Process Fee Ord 176,300 | Cleared | 4/8/2022 | DAGOVERTO GUERRERO |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| ALEXANDER HANDY, (818) 774-4317 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 6/27/2022 | Approved | STEVEN BACK |
| Footing/Foundation/Slab | 6/27/2022 | Approved | STEVEN BACK |
| PLUMBING-Rough | 6/27/2022 | Partial Approval | STEVEN BACK |
| Sewer | 6/27/2022 | Approved | STEVEN BACK |
| Underground Mechanical | 6/27/2022 | Approved | STEVEN BACK |
| Deputy Drilled-In Anchors | 6/29/2022 | Conditional Approval | MORRIS JACKSON |
| BUILDING-Rough-Frame | 7/8/2022 | Approved | STEVEN BACK |
| ELECTRICAL-Rough | 7/8/2022 | Approved | STEVEN BACK |
| HVAC-Rough | 7/8/2022 | Approved | STEVEN BACK |
| PLUMBING-Rough | 7/8/2022 | Approved | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 7/12/2022 | Approved | STEVEN BACK |
| Green Building Rough | 7/12/2022 | Approved | STEVEN BACK |
| Insulation | 7/12/2022 | Not Ready for Inspection | STEVEN BACK |
| Interior/Exterior Lathing | 7/12/2022 | Partial Approval | STEVEN BACK |
| Insulation | 7/14/2022 | Approved | STEVEN BACK |
| Drywall Nailing | 7/18/2022 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 7/18/2022 | Approved | STEVEN BACK |
| Final | 8/10/2022 | Corrections Issued | STEVEN BACK |
| Green Building Final | 8/10/2022 | Approved | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 8/10/2022 | SGSOV Approved | STEVEN BACK |
| Smoke Detectors | 8/10/2022 | Approved | STEVEN BACK |
| ELECTRICAL-Final | 8/19/2022 | Approved | STEVEN BACK |
| Final | 8/19/2022 | OK to Issue CofO | STEVEN BACK |
| PLUMBING-Final | 8/19/2022 | Approved | STEVEN BACK |