6200 N LANKERSHIM BLVD 91606

Certificate Information: 6200 N LANKERSHIM BLVD 91606

Application / Permit
22016-20000-04095
Plan Check / Job No.
B22VN02158
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(15) Telecommunication Transmitter - wireless
Work Description
ePlan SECTOR SCOPE OF WORK *Install (3) proposed 5G panel antennas (1 per sector) - 3 Future CBRS Antennas with integrated radio (1 per sector) * Install (3) proposed FRP screen boxes (1 per sector) * Install proposed jumpers * Install (6) Proposed RRUs (2 per sector) * Install (3) Proposed surge suppression device ( 1 per sector) * Install (3) proposed hybrid cables (1 per sector ) * Install proposed cable tray on roof EQUIPMENT SCOPE OF WORK *Install (1) proposed equipment platform with utility H-Frame * Install (1) proposed BBU in Cabinet * Install (1) Proposed equipment cabinet * Install (1) proposed power conduit * Install (1) proposed telco conduit * Install (1) proposed NEMA 3 Telco-Fiber Box * Install (1) proposed GPS Antenna * Install Camlock Gen Lug Intersect at ground level
Permit Issued
Issued on 1/4/2023
Issuing Office
Current Status
Permit Finaled on 11/7/2023

Permit Application Status History

Submitted 2/11/2022 APPLICANT
Assigned to Plan Check Engineer 2/11/2022 CELESTE MORRIS
Corrections Issued 2/12/2022 CELESTE MORRIS
Applicant returned to address corrections 4/25/2022 CELESTE MORRIS
Plan Check Approved 5/3/2022 CELESTE NGUYEN
Issued 1/4/2023 APPLICANT
Permit Finaled 11/7/2023 KENNETH ROBERTS

Permit Application Clearance Information

"Q" conditions Cleared 4/22/2022 KATHERINE RICE
Miscellaneous Cleared 4/22/2022 KATHERINE RICE
Miscellaneous Cleared 4/22/2022 KATHERINE RICE
Plan Approval Cleared 4/22/2022 KATHERINE RICE
ZA Case Cleared 4/22/2022 KATHERINE RICE
ZA Case Cleared 4/22/2022 KATHERINE RICE
ZA Case Cleared 4/22/2022 KATHERINE RICE
ZA Case Cleared 4/22/2022 KATHERINE RICE
ZA Case Cleared 4/22/2022 KATHERINE RICE

Contact Information

Engineer Connell,, Daniel Michael; Lic. No.: NA62543       ,

Inspector Information

JEFFREY FULTON, (818) 374-1132 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Deputy Drilled-In Anchors 3/6/2023 Conditional Approval ROBERT DAVIS
Interior/Exterior Lathing 4/17/2023 Approved ROBERT DAVIS
Wood Frame 4/17/2023 Approved ROBERT DAVIS
Final 11/7/2023 Permit Finaled KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 11/7/2023 SGSOV Approved KENNETH ROBERTS
Smoke Detectors 11/7/2023 Approved KENNETH ROBERTS