10423 N RUFFNER AVE 91344
Certificate Information: 10423 N RUFFNER AVE 91344
- Application / Permit
- 22016-20000-03453
- Plan Check / Job No.
- B22VN01824
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR REMODEL TO CONVERT A PORTION OF THE LAUNDRY ROOM INTO A (N) BATHROOM AND REMOVE WALLS. ALL WORK PER ENGINEER.
- Permit Issued
- Issued on 2/22/2022
- Issuing Office
- Current Status
- Permit Finaled on 9/23/2022
Permit Application Status History
| Submitted | 2/4/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 2/7/2022 | PINANK PATEL |
| Corrections Issued | 2/7/2022 | PINANK PATEL |
| Plan Check Approved | 2/7/2022 | PINANK PATEL |
| Plan Check Approved | 2/10/2022 | PINANK PATEL |
| Issued | 2/22/2022 | APPLICANT |
| Permit Finaled | 9/23/2022 | JAVIER RAMOS JR |
Permit Application Clearance Information
| No Data Available. |
Contact Information
| Contractor | Lifetime Home Builders Inc; Lic. No.: 1050605-B | 1545 NORTH VERDUGO RD STE 232 GLENDALE, CA 91208 |
| Engineer | Mani,, Dev; Lic. No.: C62778 | P O BOX 1451 DUARTE, CA 91009 |
Inspector Information
| CHRISTOPHER ROJAS, (818) 374-1160 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 3/7/2022 | Corrections Issued | MICHAEL TEMPLE |
| Excavation/Setback/Form/Re-Bar | 3/10/2022 | Approved | DEANDRE HOFFMAN |
| Footing/Foundation/Slab | 3/10/2022 | Approved | DEANDRE HOFFMAN |
| Structural Steel Frame | 4/8/2022 | Conditional Approval | JAVIER RAMOS JR |
| ELECTRICAL-Rough | 4/15/2022 | Not Ready for Inspection | MICHAEL TEMPLE |
| PLUMBING-Rough | 4/15/2022 | Approved | MICHAEL TEMPLE |
| Special/Order Compliance | 4/15/2022 | Corrections Issued | MICHAEL TEMPLE |
| BUILDING-Rough-Frame | 4/26/2022 | Corrections Issued | MICHAEL TEMPLE |
| ELECTRICAL-Rough | 4/26/2022 | Approved | MICHAEL TEMPLE |
| BUILDING-Rough-Frame | 5/2/2022 | Partial Approval | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 5/2/2022 | Partial Approval | JAVIER RAMOS JR |
| Insulation | 5/4/2022 | Approved | JAVIER RAMOS JR |
| Drywall Nailing | 5/10/2022 | Partial Approval | JAVIER RAMOS JR |
| Interior/Exterior Lathing | 5/10/2022 | Approved | JAVIER RAMOS JR |
| Shower Pan | 5/10/2022 | Approved | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 9/8/2022 | SGSOV Not Ready | JAVIER RAMOS JR |
| ELECTRICAL-Final | 9/12/2022 | Approved | JAVIER RAMOS JR |
| Final | 9/12/2022 | Corrections Issued | JAVIER RAMOS JR |
| HVAC-Final | 9/12/2022 | Approved | JAVIER RAMOS JR |
| PLUMBING-Final | 9/12/2022 | Approved | JAVIER RAMOS JR |
| SGSOV-Seismic Gas S/O Valve | 9/12/2022 | SGSOV Approved | JAVIER RAMOS JR |
| Smoke Detectors | 9/12/2022 | Approved | JAVIER RAMOS JR |
| Final | 9/23/2022 | Permit Finaled | JAVIER RAMOS JR |