1024 N ORANGE DR 90038
Certificate Information: 1024 N ORANGE DR 90038
- Application / Permit
- 22016-10000-38701
- Plan Check / Job No.
- B22LA25948
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Commercial
- Primary Use
- (13) Office
- Work Description
- ePlan Eplan RETROFIT EXISTING 2 STORY URM STRUCTURE PER DIVISION 88 URM ORDINANCE WITH HAZARD CLASS III-C RATING. NEW CORE AND SHELL SCOPE WILL SEISMICALLY UPGRADE TO HAZARD CLASS II RATING PER APPENDIX A1 OF CEBC. TENANT IMPROVEMENT DESIGN SCOPE IS NOT PART OF CORE AND SHELL PACKAGE, HOWEVER ANY ALTERATIONS AND ADDITIONAL SEISMIC WEIGHT FROM TENANT IMPROVEMENT SCOPE ARE CONSIDERED WITHIN CORE AND SHELL SEISMIC UPGRADE
- Permit Issued
- Issued on 5/3/2023
- Issuing Office
- Current Status
- Permit Finaled on 4/17/2024
Permit Application Status History
| Submitted | 12/26/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/19/2023 | SERGIO GUTIERREZ |
| Corrections Issued | 1/23/2023 | SERGIO GUTIERREZ |
| Quality Review Completed | 1/27/2023 | RODOLFO ARIAS |
| Applicant returned to address corrections | 3/6/2023 | SERGIO GUTIERREZ |
| Applicant returned to address corrections | 3/23/2023 | SERGIO GUTIERREZ |
| Plan Check Approved | 4/27/2023 | SERGIO GUTIERREZ |
| Issued | 5/3/2023 | APPLICANT |
| Permit Finaled | 4/16/2024 | MARTIN TAVITIAN |
Permit Application Clearance Information
| ZI | Cleared | 1/30/2023 | MAXFIELD VERMY |
| Fire Marshal Fire Life Safety | Cleared | 3/22/2023 | DOMINIQUE MEDINA |
| Green Code | Cleared | 4/5/2023 | Samuel Gonzalez |
| DAS Clearance | Cleared | 4/6/2023 | Samuel Gonzalez |
Contact Information
| Architect | Lantz,, Andrew; Lic. No.: C38831 | 510 TAMARAC DRIVE PASADENA, CA 91105 |
| Contractor | Corporate Contractors Inc; Lic. No.: 604407-B | 2550 CORPORATE PL STE C-111 MONTEREY PARK, CA 91754 |
| Engineer | Wilkerson,, Ryan Lee; Lic. No.: S4728 | 20734 SARDINIA WAY PORTER RANCH, CA 91326 |
Inspector Information
| IAN BLINN, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
| CHRISTOPHER BLACKWOOD, (213) 482-7361 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 5/9/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Steel/Welding | 5/9/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Drilled-In Anchors | 5/10/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Steel/Welding | 5/10/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Drilled-In Anchors | 5/17/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Concrete | 5/17/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Steel/Welding | 5/17/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Drilled-In Anchors | 5/18/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Concrete | 5/18/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Steel/Welding | 5/18/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Footing/Foundation/Slab | 5/18/2023 | Partial Approval | JEROME BLACKWOOD |
| Deputy Drilled-In Anchors | 5/19/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Concrete | 5/19/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Steel/Welding | 5/19/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Masonry | 5/22/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Footing/Foundation/Slab | 5/24/2023 | Partial Approval | JEROME BLACKWOOD |
| Masonry Wall/Backfill | 5/24/2023 | Partial Approval | JEROME BLACKWOOD |
| Deputy Reinf. Masonry | 5/30/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Masonry | 5/31/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Masonry | 6/1/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Masonry Wall/Backfill | 6/1/2023 | Partial Approval | JEROME BLACKWOOD |
| Deputy Reinf. Masonry | 6/2/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Masonry | 6/5/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Shotcrete | 6/7/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Deputy Reinf. Masonry | 6/12/2023 | No Access for Inspection | ALFREDO LOPEZ |
| Deputy Drilled-In Anchors | 6/14/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Wall Anchors | 6/15/2023 | Partial Inspection | GREGORY POMISH |
| Wood Frame | 6/15/2023 | Not Ready for Inspection | GREGORY POMISH |
| Deputy Drilled-In Anchors | 6/21/2023 | Conditional Approval | MICHAEL ROSENBERG |
| Wood Frame | 7/24/2023 | Partial Approval | GREGORY POMISH |
| Deputy Reinf. Concrete | 1/4/2024 | Conditional Approval | RICARDO ROBLES |
| Final | 3/21/2024 | Partial Inspection | JACOB MYERS |
| Green Building Final | 3/21/2024 | Not Ready for Inspection | JACOB MYERS |
| SGSOV-Seismic Gas S/O Valve | 3/21/2024 | SGSOV No Gas | JACOB MYERS |
| Smoke Detectors | 3/21/2024 | Partial Inspection | JACOB MYERS |
| Final | 4/16/2024 | Permit Finaled | MARTIN TAVITIAN |
| Green Building Final | 4/16/2024 | Approved | MARTIN TAVITIAN |
| Smoke Detectors | 4/16/2024 | Approved | MARTIN TAVITIAN |