11900 W OLYMPIC BLVD 90064

Certificate Information: 11900 W OLYMPIC BLVD 90064

Application / Permit
22016-10000-26639
Plan Check / Job No.
B22LA17580
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Commercial
Primary Use
(13) Office
Work Description
Eplan New Wireless rooftop antena SECTOR SCOPE OF WORK: INSTALL (6) PROPOSED PANEL ANTENNAS (2 PER SECTOR) INSTALL (9) PROPOSED ANTENNA MOUNTS INSTALL PROPOSED JUMPERS INSTALL (12) PROPOSED RRHs (4 PER SECTOR) INSTALL (3) PROPOSED OVER VOLTAGE PROTECTION DEVICE (OVP) (1 PER SECTOR) INSTALL (3) PROPOSED HYBRID CABLES INSTALL PROPOSED CABLE TRAYS ROOFTOP SCOPE OF WORK: INSTALL (1) PROPOSED METAL PLATFORM WITH H-FRAME INSTALL (1) PROPOSED CABLE TRAY INSTALL (1) PROPOSED BBU IN CABINET INSTALL (1) PROPOSED EQUIPMENT CABINET INSTALL (1) PROPOSED POWER CONDUIT INSTALL (1) PROPOSED TELCO CONDUIT INSTALL (1) PROPOSED NEMA 3 TELCO-FIBER BOX INSTALL (1) PROPOSED GPS UNIT INSTALL (3) PROPOSED RE-FRIENDLY FRP SCREEN ANTENNA ENCLOSURE INSTALL (1) PROPOSED GEN PLUG INTERSECT CAMLOCK AT GROUND LEVEL
Permit Issued
Issued on 5/10/2023
Issuing Office
Current Status
Permit Finaled on 10/31/2023

Permit Application Status History

Submitted 10/7/2022 APPLICANT
Assigned to Plan Check Engineer 10/27/2022 MONICA RAMIREZ
Corrections Issued 11/9/2022 MONICA RAMIREZ
Quality Review Completed 11/10/2022 RODOLFO ARIAS
Applicant returned to address corrections 1/25/2023 MONICA RAMIREZ
Plan Check Approved 2/27/2023 MONICA RAMIREZ
Issued 5/10/2023 APPLICANT
Permit Finaled 10/31/2023 CASIMIR BRITTON

Permit Application Clearance Information

Specific Plan Cleared 1/4/2023 KYLE WINSTON
Plan Approval Cleared 1/18/2023 SANTOS SANCHEZ

Contact Information

Contractor Vantage Telecom Company; Lic. No.: 1100156-A 3820 STATE SUITE B      SANTA BARBARA, CA 93110
Engineer Persellin,, Esra; Lic. No.: C88844 885 ORION WAY      SAN MARCOS, CA 92078

Inspector Information

CASIMIR BRITTON, (310) 914-3913 Office Hours: 7:00-8:00 AM MON-FRI
SHAVONNE ESPINOZA, (310) 914-3913 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 8/16/2023 Not Ready for Inspection SORIN CIRSTOIU
Wood Frame 9/21/2023 Approved MICHAEL PETRUSKO
Deputy Reinf. Concrete 10/3/2023 Conditional Approval MICHAEL PETRUSKO
Final 10/31/2023 Permit Finaled CASIMIR BRITTON
SGSOV-Seismic Gas S/O Valve 10/31/2023 SGSOV Approved CASIMIR BRITTON
Smoke Detectors 10/31/2023 Approved CASIMIR BRITTON