12427 W SUNSET BLVD 90049
Certificate Information: 12427 W SUNSET BLVD 90049
- Application / Permit
- 22016-10000-23759
- Plan Check / Job No.
- B22LA15752
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- EXTERIOR AND INTERIOR REMODEL TO EXISTING 2 STORY SINGLE FAMILY DEWLLING WITH ATTACHED CARPORT. (no change in floor area, height)
- Permit Issued
- Issued on 9/20/2022
- Issuing Office
- Current Status
- Permit Finaled on 3/7/2023
Permit Application Status History
| Submitted | 8/9/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 8/11/2022 | AUNG SOE |
| Corrections Issued | 8/16/2022 | AUNG SOE |
| Plan Check Approved | 8/30/2022 | STANLEY RAAP |
| Issued | 9/20/2022 | APPLICANT |
| Building Plans Picked Up | 9/21/2022 | APPLICANT |
| Permit Finaled | 3/6/2023 | MICHAEL PELHAM |
Permit Application Clearance Information
| ZA Case | Cleared | 8/16/2022 | MAXFIELD VERMY |
| Grading Pre-Inspection | Cleared | 8/19/2022 | KIRK LINKLATER |
Contact Information
| Architect | Noteware,, Brian Arthur; Lic. No.: C21514 | 845 20TH STREET, #106 SANTA MONICA, CA 90403 |
| Contractor | Williamson John Construction Inc; Lic. No.: 451421-B | 8723 BLERIOT AVE LOS ANGELES, CA 90045 |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| BUILDING-Rough-Frame | 11/9/2022 | Corrections Issued | JUAN VALENZUELA |
| Deputy Reinf. Concrete | 11/9/2022 | Corrections Issued | JUAN VALENZUELA |
| ELECTRICAL-Rough | 11/9/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 11/17/2022 | Not Ready for Inspection | JUAN VALENZUELA |
| PLUMBING-Rough | 11/17/2022 | Partial Approval | JUAN VALENZUELA |
| Shower Pan | 11/28/2022 | Partial Approval | KENNETH NAGLE |
| ELECTRICAL-Rough | 12/6/2022 | Corrections Issued | DAVID FEILER |
| PLUMBING-Rough | 12/6/2022 | Corrections Issued | DAVID FEILER |
| ELECTRICAL-Rough | 12/12/2022 | Not Ready for Inspection | KEVIN SARGSYAN |
| ELECTRICAL-Rough | 12/13/2022 | Not Ready for Inspection | ASHLEY THOMPSON |
| PLUMBING-Rough | 12/13/2022 | Not Ready for Inspection | ASHLEY THOMPSON |
| ELECTRICAL-Rough | 12/16/2022 | Not Ready for Inspection | ASHLEY THOMPSON |
| PLUMBING-Rough | 12/16/2022 | Not Ready for Inspection | ASHLEY THOMPSON |
| ELECTRICAL-Rough | 12/21/2022 | Approved | JUAN VALENZUELA |
| Interior/Exterior Lathing | 12/21/2022 | Partial Approval | JUAN VALENZUELA |
| PLUMBING-Rough | 12/21/2022 | Approved | JUAN VALENZUELA |
| Shower Pan | 12/21/2022 | Approved | JUAN VALENZUELA |
| BUILDING-Rough-Frame | 12/23/2022 | Approved | JUAN VALENZUELA |
| HVAC-Rough | 12/23/2022 | Approved | JUAN VALENZUELA |
| Drywall Nailing | 12/30/2022 | Approved | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 12/30/2022 | Not Ready for Inspection | KEVIN SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 12/30/2022 | SGSOV Not Ready | KEVIN SARGSYAN |
| Interior/Exterior Lathing | 1/25/2023 | Approved | KEVIN SARGSYAN |
| Gas Test | 2/16/2023 | Approved | HERBERT GIRON |
| Final | 2/27/2023 | No Access for Inspection | KEVIN SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 2/27/2023 | SGSOV Not Ready | KEVIN SARGSYAN |
| Smoke Detectors | 2/27/2023 | No Access for Inspection | KEVIN SARGSYAN |
| Final | 2/28/2023 | Corrections Issued | KEVIN SARGSYAN |
| SGSOV-Seismic Gas S/O Valve | 2/28/2023 | SGSOV Approved | KEVIN SARGSYAN |
| Smoke Detectors | 2/28/2023 | Approved | KEVIN SARGSYAN |
| ELECTRICAL-Final | 3/3/2023 | Approved | KEVIN SARGSYAN |
| PLUMBING-Final | 3/3/2023 | Approved | KEVIN SARGSYAN |
| Final | 3/6/2023 | Permit Finaled | MICHAEL PELHAM |