2709 S OAKHURST AVE 90034
Certificate Information: 2709 S OAKHURST AVE 90034
- Application / Permit
- 22016-10000-15973
- Plan Check / Job No.
- B22LA09966
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- INTERIOR REMODEL: PROPOSED KITCHEN, MASTER BEDROOM, BATHROOM'S, DINING AND LIVIING ROOM REMODEL
- Permit Issued
- Issued on 8/16/2022
- Issuing Office
- Metro
- Current Status
- Permit Finaled on 4/24/2024
Permit Application Status History
| Submitted | 5/25/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 5/25/2022 | ADAM HEGAZI |
| Corrections Issued | 5/25/2022 | ADAM HEGAZI |
| Plan Check Approved | 6/22/2022 | JOSEPH RAFOLS |
| Issued | 8/16/2022 | APPLICANT |
| Permit Finaled | 4/23/2024 | OGANES TARAKHCHYAN |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 6/8/2022 | KIRK LINKLATER |
Contact Information
| Architect | Noteware,, Brian Arthur; Lic. No.: C21514 | 845 20TH STREET, #106 SANTA MONICA, CA 90403 |
| Contractor | Houck Construction Inc; Lic. No.: 768547-B | 1531 PONTIUS AVENUE LOS ANGELES, CA 90025 |
Inspector Information
| ASHLEY THOMPSON, (310) 914-3897 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 3/1/2023 | Partial Approval | ASHLEY THOMPSON |
| Deputy Drilled-In Anchors | 4/13/2023 | Conditional Approval | DAVID FEILER |
| ELECTRICAL-Rough | 4/19/2023 | Corrections Issued | CLAYTON GRAHAM |
| HVAC-Rough | 4/19/2023 | Corrections Issued | CLAYTON GRAHAM |
| PLUMBING-Rough | 4/19/2023 | Corrections Issued | CLAYTON GRAHAM |
| ELECTRICAL-Rough | 4/28/2023 | Approved | CLAYTON GRAHAM |
| HVAC-Rough | 4/28/2023 | Approved | CLAYTON GRAHAM |
| PLUMBING-Rough | 4/28/2023 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/5/2023 | Corrections Issued | CLAYTON GRAHAM |
| Floor/Roof Diaphrgm/Shear Wall | 5/5/2023 | Partial Approval | CLAYTON GRAHAM |
| PLUMBING-Rough | 5/5/2023 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/16/2023 | Not Ready for Inspection | CLAYTON GRAHAM |
| Footing/Foundation/Slab | 5/16/2023 | Approved | CLAYTON GRAHAM |
| PLUMBING-Rough | 5/16/2023 | Approved | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 5/17/2023 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 6/9/2023 | Approved | CLAYTON GRAHAM |
| Insulation | 6/9/2023 | Approved | CLAYTON GRAHAM |
| Interior/Exterior Lathing | 6/9/2023 | Approved | CLAYTON GRAHAM |
| Shower Pan | 6/9/2023 | Approved | CLAYTON GRAHAM |
| Drywall Nailing | 6/15/2023 | Approved | JESUS PINEDA |
| Interior/Exterior Lathing | 6/26/2023 | Partial Approval | CLAYTON GRAHAM |
| ELECTRICAL-Final | 4/10/2024 | Corrections Issued | OGANES TARAKHCHYAN |
| HVAC-Final | 4/10/2024 | Corrections Issued | OGANES TARAKHCHYAN |
| PLUMBING-Final | 4/10/2024 | Corrections Issued | OGANES TARAKHCHYAN |
| SGSOV-Seismic Gas S/O Valve | 4/10/2024 | SGSOV Approved | OGANES TARAKHCHYAN |
| Smoke Detectors | 4/10/2024 | Approved | OGANES TARAKHCHYAN |
| ELECTRICAL-Final | 4/23/2024 | Approved | OGANES TARAKHCHYAN |
| Final | 4/23/2024 | Permit Finaled | OGANES TARAKHCHYAN |
| HVAC-Final | 4/23/2024 | Approved | OGANES TARAKHCHYAN |
| PLUMBING-Final | 4/23/2024 | Approved | OGANES TARAKHCHYAN |