212 S MOTT ST 90033

Certificate Information: 212 S MOTT ST 90033

Application / Permit
22016-10000-09655
Plan Check / Job No.
B22LA05446
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT EXISTING GARAGE TO ADU all work done per engineer design (1,200 SF max per Ordinance, LAMC 12.22 A.33 (c)-(d))
Permit Issued
Issued on 5/13/2022
Issuing Office
Metro
Current Status
CofO Issued on 3/4/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 4/8/2022 APPLICANT
Assigned to Plan Check Engineer 4/19/2022 KHUONG TRUONG
Corrections Issued 4/19/2022 KHUONG TRUONG
Building Plans Picked Up 4/21/2022 APPLICANT
Plan Check Approved 5/9/2022 AUNG SOE
Issued 5/13/2022 APPLICANT
CofO in Progress 12/14/2022 FREDDIE RIVERA
Permit Finaled 3/4/2023 DANIEL ORRANTE
CofO Issued 3/4/2023 DANIEL ORRANTE
Permit Finaled 3/4/2023 DANIEL ORRANTE

Permit Application Clearance Information

Tenant Habitability Plan Cleared 4/25/2022 MICHAEL SOTO
Address approval Cleared 4/26/2022 JEANETTE VONG
Sewer availability Cleared 4/26/2022 JEANETTE VONG
Eng Process Fee Ord 176,300 Cleared 4/27/2022 JEANETTE VONG
Grading Pre-Inspection Cleared 4/28/2022 ROBERT HUGHES

Contact Information

Contractor Owner-Builder       ,
Engineer Jung,, Jiwon; Lic. No.: C89281 2700 E 2ND ST      LOS ANGELES, CA 90033

Inspector Information

FREDDIE RIVERA, (213) 202-3437 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Pre-Inspection 10/18/2022 Corrections Issued FREDDIE RIVERA
Rough-Elec/Plmb/HVAC 10/18/2022 Partial Inspection FREDDIE RIVERA
Footing/Foundation/Slab 10/20/2022 Corrections Issued FREDDIE RIVERA
ELECTRICAL-Rough 10/27/2022 Partial Inspection FREDDIE RIVERA
Insulation 10/27/2022 Partial Inspection FREDDIE RIVERA
Wood Frame 10/27/2022 Partial Inspection FREDDIE RIVERA
ELECTRICAL-Rough 10/28/2022 Approved FREDDIE RIVERA
HVAC-Rough 10/28/2022 Approved FREDDIE RIVERA
Insulation 10/28/2022 Partial Approval FREDDIE RIVERA
PLUMBING-Rough 10/28/2022 Corrections Issued FREDDIE RIVERA
BUILDING-Rough-Frame 11/4/2022 Partial Approval ALIZAH MAYAGOITIA
ELECTRICAL-Rough 11/4/2022 Approved ALIZAH MAYAGOITIA
Insulation 11/4/2022 Approved ALIZAH MAYAGOITIA
METHANE-Final 11/4/2022 Not Ready for Inspection ALIZAH MAYAGOITIA
METHANE-Rough 11/4/2022 Approved ALIZAH MAYAGOITIA
PLUMBING-Rough 11/4/2022 Approved ALIZAH MAYAGOITIA
Smoke Detectors 11/4/2022 Not Ready for Inspection ALIZAH MAYAGOITIA
BUILDING-Rough-Frame 11/9/2022 Partial Inspection FREDDIE RIVERA
METHANE-Rough 11/9/2022 Partial Inspection FREDDIE RIVERA
Smoke Detectors 11/9/2022 Partial Inspection FREDDIE RIVERA
BUILDING-Rough-Frame 11/18/2022 Approved FREDDIE RIVERA
Final 11/18/2022 Corrections Issued FREDDIE RIVERA
METHANE-Final 11/18/2022 Approved FREDDIE RIVERA
METHANE-Rough 11/18/2022 Approved FREDDIE RIVERA
Smoke Detectors 11/18/2022 Approved FREDDIE RIVERA
Final 11/23/2022 Conditional Approval FREDDIE RIVERA
Final 11/23/2022 Off-Hour Fees Due
Final 12/13/2022 OK to Issue CofO FREDDIE RIVERA
Service/Power Release 12/28/2022 Approved FREDDIE RIVERA