5720 N COLFAX AVE 91601
Certificate Information: 5720 N COLFAX AVE 91601
- Application / Permit
- 22016-10000-09049
- Plan Check / Job No.
- B22LA05062
- Group
- Building
- Type
- Bldg-Alter/Repair
- Sub-Type
- Apartment
- Primary Use
- (5) Apartment
- Work Description
- Eplan: Soft-Story seismic retrofit per LABC Chapter 93: SOFT STORY SEISMIC REINFORCEMENT AT BUILDING PARKING GARAGE USING (1) SPECIAL CANTILEVERED COLUMN W/ GRADE BEAM
- Permit Issued
- Issued on 9/28/2022
- Issuing Office
- Current Status
- CofC Issued on 1/25/2023
Permit Application Status History
| Submitted | 3/22/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 4/14/2022 | JESSE VIDUYA |
| Corrections Issued | 4/26/2022 | JESSE VIDUYA |
| Quality Review Completed | 5/3/2022 | HANS SANTIAGO |
| Applicant returned to address corrections | 6/6/2022 | JESSE VIDUYA |
| Applicant returned to address corrections | 6/21/2022 | JESSE VIDUYA |
| Applicant returned to address corrections | 6/29/2022 | JESSE VIDUYA |
| Applicant returned to address corrections | 7/15/2022 | JESSE VIDUYA |
| Plan Check Approved | 7/22/2022 | JESSE VIDUYA |
| Issued | 9/28/2022 | APPLICANT |
| OK for CofC | 1/5/2023 | KENNETH ROBERTS |
| CofC Issued | 1/25/2023 | RICKEY JACKSON |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 9/23/2022 | MICHAEL SOTO |
Contact Information
| Contractor | Retrofit 1; Lic. No.: 1003868-B | 19326 VENTURA BLVD STE 200 TARZANA, CA 91356 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: C68149 | 8232 GARVEY AVE 203 ROSEMEAD, CA 91770 |
| Engineer | Ni,, Zhang Yuan; Lic. No.: NA68149 | , |
Inspector Information
| No Data Available. |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 10/13/2022 | Approved | KENNETH ROBERTS |
| Deputy Steel/Welding | 10/21/2022 | Conditional Approval | KENNETH ROBERTS |
| Deputy Drilled-In Anchors | 10/27/2022 | Conditional Approval | KENNETH ROBERTS |
| Footing/Foundation/Slab | 10/28/2022 | Approved | KENNETH ROBERTS |
| Structural Steel Frame | 10/28/2022 | Approved | KENNETH ROBERTS |
| Wood Frame | 10/28/2022 | Approved | KENNETH ROBERTS |
| Deputy Reinf. Concrete | 11/1/2022 | Conditional Approval | KENNETH ROBERTS |
| Interior/Exterior Lathing | 11/7/2022 | Approved | KENNETH ROBERTS |
| Final | 12/20/2022 | Partial Inspection | KENNETH ROBERTS |
| SGSOV-Seismic Gas S/O Valve | 12/20/2022 | SGSOV Approved | KENNETH ROBERTS |
| Smoke Detectors | 12/20/2022 | Not Ready for Inspection | KENNETH ROBERTS |
| Final | 1/5/2023 | OK for CofC | KENNETH ROBERTS |
| Smoke Detectors | 1/5/2023 | Approved | KENNETH ROBERTS |