20405 W SHERMAN WAY 91306

Certificate Information: 20405 W SHERMAN WAY 91306

Application / Permit
22016-10000-07222
Plan Check / Job No.
B22LA04399
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
Apartment
Primary Use
(5) Apartment
Work Description
SOFT-STORY RETROFIT PER LABC CH.93 USING SHEAR WALLS AND SPECIAL STEEL CANTILEVER COLUMNS. 1 OF 2
Permit Issued
Issued on 7/28/2022
Issuing Office
Metro
Current Status
CofC Issued on 6/20/2023

Permit Application Status History

Submitted 3/11/2022 APPLICANT
Assigned to Plan Check Engineer 4/7/2022 VARAND SARKISIAN
Corrections Issued 4/14/2022 VARAND SARKISIAN
Quality Review Completed 4/15/2022 HANS SANTIAGO
Building Plans Picked Up 4/18/2022 APPLICANT
Plan Check Approved 6/27/2022 VARAND SARKISIAN
Issued 7/28/2022 APPLICANT
OK for CofC 4/13/2023 KENNETH ROBERTS
CofC Issued 6/20/2023 RICKEY JACKSON

Permit Application Clearance Information

Tenant Habitability Plan Cleared 7/12/2022 RICARDO BOHORQUEZ

Contact Information

Architect Stockton,, Kenneth; Lic. No.: C19870 26500 W AGOURA RD. PMB # 844      CALABASAS, CA 91302
Contractor Donaldson John R Construction Inc; Lic. No.: 641405-B 14320 VENTURA BLVD 610      SHERMAN OAKS, CA 91423
Engineer Warling,, Jeffrey Paul; Lic. No.: C43743 1792 PEREGRINE CT      SIMI VALLEY, CA 93065

Inspector Information

No Data Available.

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 8/17/2022 Partial Approval KENNETH ROBERTS
Footing/Foundation/Slab 9/8/2022 Corrections Issued KENNETH ROBERTS
Footing/Foundation/Slab 9/9/2022 Partial Approval KENNETH ROBERTS
Deputy Reinf. Concrete 9/12/2022 Conditional Approval KENNETH ROBERTS
Footing/Foundation/Slab 12/1/2022 Partial Inspection JEFFREY FULTON
Deputy Reinf. Concrete 12/5/2022 Conditional Approval KENNETH ROBERTS
Structural Steel Frame 1/10/2023 Partial Inspection KENNETH ROBERTS
Wood Frame 1/10/2023 Partial Inspection KENNETH ROBERTS
Deputy Steel/Welding 1/13/2023 Conditional Approval JEFFREY FULTON
Structural Steel Frame 1/13/2023 Not Ready for Inspection JEFFREY FULTON
Wood Frame 1/13/2023 Not Ready for Inspection JEFFREY FULTON
Structural Steel Frame 1/18/2023 Partial Inspection JEFFREY FULTON
Wood Frame 1/18/2023 Partial Inspection JEFFREY FULTON
Floor/Roof Diaphrgm/Shear Wall 1/24/2023 Approved KENNETH ROBERTS
Interior/Exterior Lathing 2/22/2023 Approved DANIEL VARNUM
Final 3/29/2023 Corrections Issued KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 3/29/2023 SGSOV Not Ready KENNETH ROBERTS
Smoke Detectors 3/29/2023 Approved KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 4/11/2023 SGSOV Not Ready STEVEN LEVITT
Final 4/12/2023 Partial Approval KENNETH ROBERTS
SGSOV-Seismic Gas S/O Valve 4/12/2023 SGSOV Approved KENNETH ROBERTS
Final 4/13/2023 OK for CofC KENNETH ROBERTS