3305 S CABRILLO BLVD 90066
Certificate Information: 3305 S CABRILLO BLVD 90066
- Application / Permit
- 22014-30000-03528
- Plan Check / Job No.
- B22WL02749
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- major remodel to remove (e) S.F.D. w/ the exception of portion of the foundation with 2-story addition with roof trusses
- Permit Issued
- Issued on 10/14/2022
- Issuing Office
- Current Status
- CofO Issued on 10/11/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 7/13/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 7/21/2022 | HOOMAN HAJIZADEH |
| Corrections Issued | 7/29/2022 | HOOMAN HAJIZADEH |
| Quality Review Completed | 8/15/2022 | CHIHARU SUZUKI |
| Applicant returned to address corrections | 10/7/2022 | HOOMAN HAJIZADEH |
| Plan Check Approved | 10/13/2022 | HOOMAN HAJIZADEH |
| Issued | 10/14/2022 | APPLICANT |
| Building Plans Picked Up | 11/23/2022 | APPLICANT |
| CofO in Progress | 10/6/2023 | JESUS RODRIGUEZ |
| Permit Finaled | 10/11/2023 | DANIEL ORRANTE |
| CofO Issued | 10/11/2023 | DANIEL ORRANTE |
| Permit Finaled | 10/11/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 8/16/2022 | CATHERINE ADROVER |
| Permit | Cleared | 8/16/2022 | CATHERINE ADROVER |
| Sewer availability | Cleared | 8/16/2022 | CATHERINE ADROVER |
| Low Impact Development | Cleared | 8/29/2022 | ROGELIO CORTES |
| Roof/Waste drainage to street | Cleared | 8/31/2022 | CATHERINE ADROVER |
| Specific Plan | Cleared | 9/9/2022 | PEDRO AYALA |
| Trees in Parkway | Cleared | 9/21/2022 | ADALBERTO VERA |
| GPI Written Notices | Cleared | 10/7/2022 | HOOMAN HAJIZADEH |
| Grading Pre-Inspection | Cleared | 10/7/2022 | HOOMAN HAJIZADEH |
Contact Information
| Architect | Walters,, Jonathan A; Lic. No.: C33220 | 4634 LAURELGROVE AVENUE STUDIO CITY, CA 91604 |
| Contractor | Gomez A Landscaping Designs; Lic. No.: 1011989-C27 | P O BOX 1387 SIMI VALLEY, CA 93062 |
| Engineer | De, Leon, Cynthia Aguilar; Lic. No.: C31604 | 8061 SAN MATEO CIR BUENA PARK, CA 90620 |
| Engineer | Nguyen,, Huan; Lic. No.: C64238 | 13831 TYPEE WAY IRVINE, CA 92620 |
| Engineer | Toedter,, Randy W; Lic. No.: S2991 | 7474 EISENHOWER ST VENTURA, CA 93003 |
Inspector Information
| DAKOTA LOW, (310) 914-3895 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 4/20/2023 | Partial Approval | JESUS RODRIGUEZ |
| Deputy Drilled-In Anchors | 4/26/2023 | Approved | EVAN COOPER |
| Excavation/Setback/Form/Re-Bar | 4/26/2023 | Approved | EVAN COOPER |
| Footing/Foundation/Slab | 4/26/2023 | Approved | EVAN COOPER |
| Floor/Roof Diaphrgm/Shear Wall | 5/10/2023 | Partial Approval | JESUS RODRIGUEZ |
| Sewer | 5/16/2023 | Approved | EVAN COOPER |
| Underground Mechanical | 5/16/2023 | Partial Approval | EVAN COOPER |
| Deputy Drilled-In Anchors | 5/23/2023 | Conditional Approval | JESUS RODRIGUEZ |
| Excavation/Setback/Form/Re-Bar | 5/25/2023 | Approved | JESUS RODRIGUEZ |
| Piling/Pier/Caisson | 5/25/2023 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 6/14/2023 | Corrections Issued | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 6/14/2023 | Conditional Approval | JESUS RODRIGUEZ |
| Floor/Roof Diaphrgm/Shear Wall | 6/16/2023 | Approved | JESUS RODRIGUEZ |
| ELECTRICAL-Rough | 6/26/2023 | Approved | EVAN COOPER |
| HVAC-Rough | 6/26/2023 | Approved | EVAN COOPER |
| PLUMBING-Rough | 6/30/2023 | Approved | JESUS RODRIGUEZ |
| Shower Pan | 6/30/2023 | Not Ready for Inspection | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 7/12/2023 | Approved | JESUS RODRIGUEZ |
| Green Building Rough | 7/12/2023 | Approved | JESUS RODRIGUEZ |
| Interior/Exterior Lathing | 7/12/2023 | Approved | JESUS RODRIGUEZ |
| BUILDING-Rough-Frame | 7/13/2023 | Approved | JESUS RODRIGUEZ |
| Green Building Rough | 7/13/2023 | Approved | JESUS RODRIGUEZ |
| Insulation | 7/17/2023 | Approved | RICHARD STEINBACH |
| Shower Pan | 7/17/2023 | Approved | RICHARD STEINBACH |
| Drywall Nailing | 7/25/2023 | Approved | JESUS RODRIGUEZ |
| Verify Sprinkler Sign Off | 7/25/2023 | Approved | JESUS RODRIGUEZ |
| Interior/Exterior Lathing | 7/27/2023 | Approved | RICHARD STEINBACH |
| Gas Test | 8/14/2023 | Partial Approval | CHRISTOPHER WILSON |
| Underground Mechanical | 8/14/2023 | Partial Approval | CHRISTOPHER WILSON |
| ELECTRICAL-Final | 9/19/2023 | Corrections Issued | HERBERT GIRON |
| HVAC-Final | 9/19/2023 | Corrections Issued | HERBERT GIRON |
| Smoke Detectors | 9/19/2023 | Approved | HERBERT GIRON |
| ELECTRICAL-Final | 9/20/2023 | Approved | HERBERT GIRON |
| Gas Test | 9/20/2023 | Not Ready for Inspection | HERBERT GIRON |
| HVAC-Final | 9/20/2023 | Approved | HERBERT GIRON |
| PLUMBING-Final | 9/20/2023 | Corrections Issued | HERBERT GIRON |
| SGSOV-Seismic Gas S/O Valve | 9/20/2023 | SGSOV Not Ready | HERBERT GIRON |
| Service/Power Release | 9/21/2023 | Approved | MICHAEL PELHAM |
| Gas Test | 9/25/2023 | Approved | JESUS RODRIGUEZ |
| PLUMBING-Final | 9/25/2023 | Approved | JESUS RODRIGUEZ |
| SGSOV-Seismic Gas S/O Valve | 9/25/2023 | SGSOV Approved | JESUS RODRIGUEZ |
| Final | 9/26/2023 | Corrections Issued | JESUS RODRIGUEZ |
| Green Building Final | 9/26/2023 | Approved | JESUS RODRIGUEZ |
| Final | 10/6/2023 | OK to Issue CofO | JESUS RODRIGUEZ |