6555 N TAMPA AVE 91335

Certificate Information: 6555 N TAMPA AVE 91335

Application / Permit
22014-20000-05997
Plan Check / Job No.
B22VN18086
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT (E) 19'-0" X 21'-10" DETACHED CARPORT AND ADD 21' X 24'-10" 2 STORY TO CREATE A (N)ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) AND (d). ALL WORK PER ENGINEERING.
Permit Issued
Issued on 7/7/2023
Issuing Office
Valley
Current Status
CofO Corrected on 8/20/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 12/9/2022 APPLICANT
Assigned to Plan Check Engineer 1/12/2023 RAPHAEL ROSAS
Corrections Issued 1/19/2023 RAPHAEL ROSAS
Quality Review Completed 1/25/2023 STEVEN KIM
Building Plans Picked Up 2/7/2023 APPLICANT
Plan Check Approved 7/5/2023 RAPHAEL ROSAS
Issued 7/7/2023 APPLICANT
CofO in Progress 6/17/2024 JEFFREY BULL
CofO Issued-Status Void 8/8/2024 JOHN JANSON
Permit Finaled-Status Void 8/8/2024 JOHN JANSON
Re-Activate Permit 8/9/2024 JOHN JANSON
CofO Corrected 8/20/2024 JOHN JANSON
Permit Finaled 8/20/2024 JOHN JANSON

Permit Application Clearance Information

Address approval Cleared 1/23/2023 MEGAN GODINEZ
Roof/Waste drainage to street Cleared 1/23/2023 MEGAN GODINEZ
ZI Cleared 1/23/2023 BRENNEN OBETO
Eng Process Fee Ord 176,300 Cleared 1/24/2023 MEGAN GODINEZ
Sewer availability Cleared 1/24/2023 MEGAN GODINEZ
Public Works-Highway Ded. Cleared 1/24/2023 MEGAN GODINEZ
Public Works-Open Permits Cleared 1/24/2023 MEGAN GODINEZ
Public Works-Sewers Cleared 1/24/2023 MEGAN GODINEZ
Construction near power lines Cleared 6/1/2023 RIDWAN HARDY

Contact Information

Contractor Owner-Builder       ,
Engineer Aronianpour,, Eilan; Lic. No.: C88101 7242 JELLICO AVE      LAKE BALBOA, CA 91406

Inspector Information

ARUTYUN MADATYAN, (818) 774-4307 Office Hours: 7:00-8:00 AM MON-FRI
JUAN ALVARADO, (818) 774-4307 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

PLUMBING-Rough 8/17/2023 Partial Approval JEFFREY BULL
Underground Mechanical 8/17/2023 Partial Approval JEFFREY BULL
Footing/Foundation/Slab 8/19/2023 Approved RAUL OLAGI
BUILDING-Rough-Frame 9/22/2023 Partial Approval JEFFREY PARD
Green Building Rough 9/22/2023 Not Ready for Inspection JEFFREY PARD
Wood Frame 9/22/2023 Approved JEFFREY PARD
BUILDING-Rough-Frame 11/2/2023 No Access for Inspection JEFFREY BULL
ELECTRICAL-Rough 11/2/2023 No Access for Inspection JEFFREY BULL
Green Building Rough 11/2/2023 No Access for Inspection JEFFREY BULL
HVAC-Rough 11/2/2023 No Access for Inspection JEFFREY BULL
PLUMBING-Rough 11/2/2023 No Access for Inspection JEFFREY BULL
Wood Frame 11/2/2023 No Access for Inspection JEFFREY BULL
ELECTRICAL-Rough 11/7/2023 Approved SEAN WIRCH
Floor/Roof Diaphrgm/Shear Wall 11/7/2023 Partial Approval SEAN WIRCH
HVAC-Rough 11/7/2023 Approved SEAN WIRCH
PLUMBING-Rough 11/7/2023 Approved SEAN WIRCH
Wood Frame 11/7/2023 Corrections Issued SEAN WIRCH
BUILDING-Rough-Frame 11/29/2023 Not Ready for Inspection JEFFREY BULL
Green Building Rough 11/29/2023 Approved JEFFREY BULL
Interior/Exterior Lathing 11/29/2023 Partial Approval JEFFREY BULL
Wood Frame 11/29/2023 Not Ready for Inspection JEFFREY BULL
Insulation 12/6/2023 Corrections Issued JEFFREY BULL
Drywall Nailing 12/15/2023 Approved JEFFREY BULL
Interior/Exterior Lathing 1/3/2024 Approved JEFFREY BULL
Shower Pan 1/3/2024 Approved JEFFREY BULL
Special/Order Compliance 2/23/2024 Corrections Issued HENRY KIM
Underground Mechanical 2/23/2024 Approved HENRY KIM
ELECTRICAL-Final 3/22/2024 Not Ready for Inspection GEVORK IPCHYAN
ELECTRICAL-Final 4/4/2024 Not Ready for Inspection JEFFREY BULL
Service/Power Release 4/4/2024 Not Ready for Inspection JEFFREY BULL
ELECTRICAL-Final 4/5/2024 Not Ready for Inspection JEFFREY BULL
Service/Power Release 4/5/2024 Approved JEFFREY BULL
BUILDING-Rough-Frame 6/3/2024 Approved JEFFREY BULL
ELECTRICAL-Final 6/3/2024 Not Ready for Inspection JEFFREY BULL
Final 6/3/2024 Corrections Issued JEFFREY BULL
Green Building Final 6/3/2024 Approved JEFFREY BULL
HVAC-Final 6/3/2024 Approved JEFFREY BULL
PLUMBING-Final 6/3/2024 Approved JEFFREY BULL
SGSOV-Seismic Gas S/O Valve 6/3/2024 SGSOV Approved JEFFREY BULL
Smoke Detectors 6/3/2024 Not Ready for Inspection JEFFREY BULL
ELECTRICAL-Final 6/7/2024 Approved MORRIS JACKSON
Final 6/7/2024 Partial Approval MORRIS JACKSON
Smoke Detectors 6/7/2024 Approved MORRIS JACKSON
Final 6/17/2024 OK to Issue CofO JEFFREY BULL