19216 W LEMAY ST 91335
Certificate Information: 19216 W LEMAY ST 91335
- Application / Permit
- 22014-20000-04758
- Plan Check / Job No.
- B22VN14400
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- REMODEL (E) SINGLE-FAMILY DWELLING WITH 4'-0" X 16'-4" & 8'-10" X 30'-0" IRREGULAR SHAPED ADDITION
- Permit Issued
- Issued on 7/12/2023
- Issuing Office
- Current Status
- CofO in Progress on 10/9/2025
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 9/23/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 9/29/2022 | LUISANGEL VALENZUELA |
| Corrections Issued | 9/30/2022 | LUISANGEL VALENZUELA |
| Applicant returned to address corrections | 12/8/2022 | ALFRED RAMIREZ |
| Applicant returned to address corrections | 6/22/2023 | ALFRED RAMIREZ |
| Plan Check Approved | 7/12/2023 | ALEC MOUSAKHANIAN |
| Issued | 7/12/2023 | APPLICANT |
| CofO in Progress | 12/19/2023 | SEAN HAUPT |
| No Progress | 1/7/2025 | SEAN WIRCH |
| CofO in Progress | 1/7/2025 | SEAN WIRCH |
| No Progress | 10/9/2025 | SEAN WIRCH |
| CofO in Progress | 10/9/2025 | SEAN WIRCH |
Permit Application Clearance Information
| Address approval | Cleared | 9/30/2022 | JOSE DUARTE-DIAZ |
| Eng Process Fee Ord 176,300 | Cleared | 9/30/2022 | JOSE DUARTE-DIAZ |
| Roof/Waste drainage to street | Cleared | 9/30/2022 | JOSE DUARTE-DIAZ |
| Sewer availability | Cleared | 9/30/2022 | JOSE DUARTE-DIAZ |
| Public Works-Highway Ded. | Cleared | 9/30/2022 | JOSE DUARTE-DIAZ |
Contact Information
| Contractor | Trinity Builders & Design Inc; Lic. No.: 988119-B | , |
| Engineer | Wassef,, Mena; Lic. No.: C84979 | 28131 VALERIO CT VALENCIA, CA 91354 |
Inspector Information
| JOHN KIDWELL, (818) 774-4314 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 7/26/2023 | Approved | JEFFREY BULL |
| Footing/Foundation/Slab | 7/26/2023 | Approved | JEFFREY BULL |
| Floor/Roof Diaphrgm/Shear Wall | 8/9/2023 | Approved | JEFFREY BULL |
| Floor/Roof Diaphrgm/Shear Wall | 10/13/2023 | Approved | SEAN HAUPT |
| BUILDING-Rough-Frame | 10/25/2023 | Approved | SEAN HAUPT |
| ELECTRICAL-Rough | 10/25/2023 | Approved | SEAN HAUPT |
| Green Building Rough | 10/25/2023 | Approved | SEAN HAUPT |
| HVAC-Rough | 10/25/2023 | Approved | SEAN HAUPT |
| Interior/Exterior Lathing | 10/25/2023 | Approved | SEAN HAUPT |
| PLUMBING-Rough | 10/25/2023 | Approved | SEAN HAUPT |
| Drywall Nailing | 11/2/2023 | Approved | SEAN HAUPT |
| Interior/Exterior Lathing | 11/2/2023 | Approved | SEAN HAUPT |
| Shower Pan | 11/2/2023 | Approved | SEAN HAUPT |
| ELECTRICAL-Final | 12/11/2023 | Approved | SEAN HAUPT |
| Final | 12/11/2023 | Corrections Issued | SEAN HAUPT |
| Green Building Final | 12/11/2023 | Not Ready for Inspection | SEAN HAUPT |
| HVAC-Final | 12/11/2023 | Approved | SEAN HAUPT |
| PLUMBING-Final | 12/11/2023 | Approved | SEAN HAUPT |
| SGSOV-Seismic Gas S/O Valve | 12/11/2023 | SGSOV Not Ready | SEAN HAUPT |
| Smoke Detectors | 12/11/2023 | Approved | SEAN HAUPT |
| ELECTRICAL-Final | 12/18/2023 | Approved | SEAN HAUPT |
| Final | 12/18/2023 | OK to Issue CofO | SEAN HAUPT |
| Green Building Final | 12/18/2023 | Approved | SEAN HAUPT |
| HVAC-Final | 12/18/2023 | Approved | SEAN HAUPT |
| PLUMBING-Final | 12/18/2023 | Approved | SEAN HAUPT |
| SGSOV-Seismic Gas S/O Valve | 12/18/2023 | SGSOV Approved | SEAN HAUPT |