6321 N ETHEL AVE 91401

Certificate Information: 6321 N ETHEL AVE 91401

Application / Permit
22014-20000-03951
Plan Check / Job No.
B22VN12012
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
eplan- CONVERT EXISTING 2 CAR DETACHED GARAGE (364 SQ FT) AND ADDING 139 SQ FT OF FLOOR AREA TO ACCESSORY DWELLING UNIT( 503 SQ FT TOTAL ADU) PER LAMC 12.22 A.33 (c)-(d)
Permit Issued
Issued on 10/7/2022
Issuing Office
Current Status
CofO Issued on 10/23/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/5/2022 APPLICANT
Assigned to Plan Check Engineer 8/12/2022 HANS SANTIAGO
Corrections Issued 8/12/2022 HANS SANTIAGO
Plan Check Approved 9/21/2022 ANDREW SANTIAGO
Issued 10/7/2022 APPLICANT
CofO in Progress 7/18/2023 KIRK SANDERS
CofO Issued 10/23/2023 RUBEN SALAS
Permit Finaled 10/23/2023 RUBEN SALAS

Permit Application Clearance Information

Address approval Cleared 9/6/2022 MEGAN GODINEZ
Roof/Waste drainage to street Cleared 9/6/2022 MEGAN GODINEZ
Eng Process Fee Ord 176,300 Cleared 9/7/2022 MEGAN GODINEZ
Sewer availability Cleared 9/16/2022 MEGAN GODINEZ
Public Works-Highway Ded. Cleared 9/16/2022 MEGAN GODINEZ
Public Works-Open Permits Cleared 9/16/2022 MEGAN GODINEZ
Public Works-Sewers Cleared 9/16/2022 MEGAN GODINEZ

Contact Information

Contractor M K Construction Co; Lic. No.: 809616-B 2816 HONOLULU AVE 707      MONTROSE, CA 91046
Engineer Li,, Dacheng D; Lic. No.: C58075 1400 N KRAEMER BLVD #712      PLACENTIA, CA 92781

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 11/30/2022 Approved KIRK SANDERS
Gas Test 11/30/2022 Approved KIRK SANDERS
Sewer 11/30/2022 Approved KIRK SANDERS
Underground Mechanical 11/30/2022 Approved KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 12/19/2022 Partial Approval MISAEL ESPARZA
ELECTRICAL-Rough 1/24/2023 Corrections Issued KIRK SANDERS
PLUMBING-Rough 1/24/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 1/25/2023 Partial Approval KIRK SANDERS
ELECTRICAL-Rough 1/25/2023 Approved KIRK SANDERS
HVAC-Rough 1/25/2023 Corrections Issued KIRK SANDERS
BUILDING-Rough-Frame 1/30/2023 Approved KIRK SANDERS
Green Building Rough 1/30/2023 Approved KIRK SANDERS
HVAC-Rough 1/30/2023 Approved KIRK SANDERS
Insulation 1/30/2023 Partial Approval KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 2/8/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 2/23/2023 Approved KIRK SANDERS
Drywall Nailing 2/23/2023 Approved KIRK SANDERS
Interior/Exterior Lathing 2/23/2023 Partial Approval KIRK SANDERS
Interior/Exterior Lathing 3/9/2023 Approved KIRK SANDERS
Shower Pan 3/9/2023 Approved KIRK SANDERS
ELECTRICAL-Final 6/16/2023 Corrections Issued KIRK SANDERS
Final 6/16/2023 Corrections Issued KIRK SANDERS
Green Building Final 6/16/2023 Not Ready for Inspection KIRK SANDERS
HVAC-Final 6/16/2023 Not Ready for Inspection KIRK SANDERS
PLUMBING-Final 6/16/2023 Corrections Issued KIRK SANDERS
SGSOV-Seismic Gas S/O Valve 6/16/2023 SGSOV Approved KIRK SANDERS
Service/Power Release 6/16/2023 Not Ready for Inspection KIRK SANDERS
Smoke Detectors 6/16/2023 Approved KIRK SANDERS
ELECTRICAL-Final 7/14/2023 Approved KIRK SANDERS
Final 7/14/2023 OK to Issue CofO KIRK SANDERS
Green Building Final 7/14/2023 Approved KIRK SANDERS
HVAC-Final 7/14/2023 Approved KIRK SANDERS
PLUMBING-Final 7/14/2023 Approved KIRK SANDERS