6503 N GREENBUSH AVE 91401

Certificate Information: 6503 N GREENBUSH AVE 91401

Application / Permit
22014-20000-03879
Plan Check / Job No.
B22VN11753
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT (E) 44'-0" x 49'-6" IRREGULAR SHAPED RECREATION ROOM WITH ATTACHED GARAGE TO A NEW (1750 S.F) ACCESSORY DWELLING UNIT PER CA Govt. Code 65852.2(e)(1)(A) AND 11'-6" x 10'-0" ATTACHED STORAGE ADDITION. WORK DONE PER ENGINEERING.
Permit Issued
Issued on 12/28/2022
Issuing Office
Valley
Current Status
CofO Issued on 11/15/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 8/1/2022 APPLICANT
Assigned to Plan Check Engineer 8/3/2022 SARKIS HARABEDIAN
Corrections Issued 8/3/2022 SARKIS HARABEDIAN
Plan Check Approved 12/27/2022 MADISON ODELL
Issued 12/28/2022 APPLICANT
CofO in Progress 9/6/2024 OGANES TARAKHCHYAN
Permit Finaled 11/15/2024 DANIEL ORRANTE
CofO Issued 11/15/2024 DANIEL ORRANTE
Permit Finaled 11/15/2024 DANIEL ORRANTE

Permit Application Clearance Information

Address approval Cleared 8/18/2022 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 8/18/2022 LEE GUILBEAUX
Roof/Waste drainage to street Cleared 8/18/2022 LEE GUILBEAUX
Sewer availability Cleared 8/18/2022 LEE GUILBEAUX
Construction near power lines Cleared 10/24/2022 RIDWAN HARDY

Contact Information

Contractor Owner-Builder       ,
Engineer Papazyan,, Andranik; Lic. No.: C56824 635 W COLORADO ST STE 104      GLENDALE, CA 91204

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Gas Test 1/4/2023 Not Ready for Inspection KIRK SANDERS
Pre-Inspection 1/4/2023 Approved KIRK SANDERS
Rough-Elec/Plmb/HVAC 1/4/2023 Not Ready for Inspection KIRK SANDERS
Pre-Inspection 3/20/2023 Approved MISAEL ESPARZA
Sewer 3/20/2023 Not Ready for Inspection MISAEL ESPARZA
Underground Mechanical 3/30/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 4/5/2023 Corrections Issued KIRK SANDERS
Green Building Rough 4/5/2023 Not Ready for Inspection KIRK SANDERS
PLUMBING-Rough 5/19/2023 Partial Approval KIRK SANDERS
PLUMBING-Rough 5/30/2023 Approved KIRK SANDERS
Sewer 5/30/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 6/13/2023 Corrections Issued KIRK SANDERS
ELECTRICAL-Rough 6/13/2023 Corrections Issued KIRK SANDERS
Green Building Rough 6/13/2023 Not Ready for Inspection KIRK SANDERS
HVAC-Rough 6/13/2023 Corrections Issued KIRK SANDERS
PLUMBING-Rough 6/13/2023 Corrections Issued KIRK SANDERS
BUILDING-Rough-Frame 6/26/2023 Not Ready for Inspection KIRK SANDERS
ELECTRICAL-Rough 6/26/2023 Corrections Issued KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 6/26/2023 Approved KIRK SANDERS
Green Building Rough 6/26/2023 Not Ready for Inspection KIRK SANDERS
HVAC-Rough 6/26/2023 Conditional Approval KIRK SANDERS
PLUMBING-Rough 6/26/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 7/5/2023 Corrections Issued KIRK SANDERS
ELECTRICAL-Rough 7/5/2023 Conditional Approval KIRK SANDERS
BUILDING-Rough-Frame 7/20/2023 Conditional Approval KIRK SANDERS
Green Building Rough 7/20/2023 Approved KIRK SANDERS
Insulation 7/31/2023 Approved KIRK SANDERS
Interior/Exterior Lathing 7/31/2023 Partial Approval KIRK SANDERS
Shower Pan 7/31/2023 Approved KIRK SANDERS
Drywall Nailing 8/11/2023 Approved MISAEL ESPARZA
Interior/Exterior Lathing 9/6/2023 Approved KIRK SANDERS
Shower Pan 9/6/2023 Approved KIRK SANDERS
HVAC-Final 12/11/2023 Corrections Issued JOSE AVILA
PLUMBING-Final 12/11/2023 Corrections Issued JOSE AVILA
PLUMBING-Final 12/18/2023 Corrections Issued JOSE AVILA
BUILDING-Rough-Frame 12/21/2023 Corrections Issued JOSE AVILA
Green Building Final 12/21/2023 Approved JOSE AVILA
PLUMBING-Final 12/21/2023 Approved JOSE AVILA
SGSOV-Seismic Gas S/O Valve 12/21/2023 SGSOV Approved JOSE AVILA
Smoke Detectors 12/21/2023 Approved JOSE AVILA
Footing/Foundation/Slab 1/5/2024 Approved KIRK SANDERS
Final 1/17/2024 Not Ready for Inspection JOSE AVILA
BUILDING-Rough-Frame 8/12/2024 Approved JOSE AVILA
Final 8/12/2024 Not Ready for Inspection JOSE AVILA
Final 8/29/2024 Corrections Issued OGANES TARAKHCHYAN
Final 9/6/2024 OK to Issue CofO OGANES TARAKHCHYAN
Service/Power Release 9/17/2024 Approved JOSE AVILA