2342 S GARTH AVE 90034
Certificate Information: 2342 S GARTH AVE 90034
- Application / Permit
- 22014-20000-02658
- Plan Check / Job No.
- B22VN08395
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 27'-0" X 13'-0" ADDITION WITH PATIO COVER TO THE (E) SFD PER ENGINEERING.
- Permit Issued
- Issued on 8/4/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 6/7/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/1/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 6/3/2022 | ARTIN ZARUKIAN |
| Corrections Issued | 6/4/2022 | ARTIN ZARUKIAN |
| Plan Check Approved | 7/15/2022 | ARTIN ZARUKIAN |
| Building Plans Picked Up | 8/1/2022 | APPLICANT |
| Issued | 8/4/2022 | APPLICANT |
| CofO in Progress | 6/7/2025 | MICHAEL PELHAM |
| Permit Finaled | 6/7/2025 | RICHARD STEINBACH |
| CofO Issued | 6/7/2025 | RICHARD STEINBACH |
| Permit Finaled | 6/7/2025 | RICHARD STEINBACH |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 7/1/2022 | JEANIE LAM |
| Roof/Waste drainage to street | Cleared | 7/1/2022 | JEANIE LAM |
| Sewer availability | Cleared | 7/1/2022 | JEANIE LAM |
Contact Information
| Contractor | Eco Renovate Pros; Lic. No.: 1054754-B | 435 S MAPLE DRIVE #1 BEVERLY HILLS, CA 90212 |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 5832 JAMIESON AVE ENCINO, CA 91316 |
Inspector Information
| WILBER ROSALES, (310) 914-3892 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 9/16/2022 | Partial Approval | ANDREW NAVE |
| Floor/Roof Diaphrgm/Shear Wall | 9/22/2022 | Not Ready for Inspection | OGANES TARAKHCHYAN |
| PLUMBING-Rough | 9/28/2022 | Partial Approval | EVAN COOPER |
| Floor/Roof Diaphrgm/Shear Wall | 10/17/2022 | Partial Approval | ANDREW NAVE |
| ELECTRICAL-Rough | 11/10/2022 | Approved | CLAYTON GRAHAM |
| PLUMBING-Rough | 11/10/2022 | Corrections Issued | CLAYTON GRAHAM |
| BUILDING-Rough-Frame | 11/22/2022 | Approved | STEPHANIE SWANSON |
| Floor/Roof Diaphrgm/Shear Wall | 11/22/2022 | Approved | STEPHANIE SWANSON |
| Green Building Rough | 11/22/2022 | Approved | STEPHANIE SWANSON |
| Insulation | 11/22/2022 | Approved | STEPHANIE SWANSON |
| MERV13>=Rough | 11/22/2022 | Approved | STEPHANIE SWANSON |
| PLUMBING-Rough | 11/22/2022 | Approved | STEPHANIE SWANSON |
| Drywall Nailing | 12/12/2022 | Approved | JEREMY TODD |
| Shower Pan | 12/12/2022 | Approved | JEREMY TODD |
| Final | 3/17/2023 | Corrections Issued | JEREMY TODD |
| Footing/Foundation/Slab | 3/17/2023 | Approved | JEREMY TODD |
| Green Building Final | 3/17/2023 | Approved | JEREMY TODD |
| MERV13>=Final | 3/17/2023 | Approved | JEREMY TODD |
| SGSOV-Seismic Gas S/O Valve | 3/17/2023 | SGSOV Approved | JEREMY TODD |
| Smoke Detectors | 3/17/2023 | Approved | JEREMY TODD |
| Final | 6/7/2025 | OK to Issue CofO | MICHAEL PELHAM |