12318 W LA MAIDA ST 91607

Certificate Information: 12318 W LA MAIDA ST 91607

Application / Permit
22014-20000-02397
Plan Check / Job No.
B22VN07566
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
IRREGULAR ADDITION ( 40' X 28'-11" ) TO REAR (E) SFD FOR NEW LIVING ROOM, BEDROOM. ADDITION (14'-11" X 10'-5") ) AT FRONT. INTERIOR REMODEL THROUGHOUT. NEW ( 26' X 15' ) IRREGULAR ATTACHED OPEN TRELLIS PATIO COVER. AUTOMATIC FIRE SPRINKLER SYSTEM REQUIRED. WORK PER ENGINEER.
Permit Issued
Issued on 9/14/2022
Issuing Office
Metro
Current Status
CofO Issued on 5/15/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 5/16/2022 APPLICANT
Assigned to Plan Check Engineer 5/19/2022 ROSENDO MEDINA
Corrections Issued 5/21/2022 ROSENDO MEDINA
Building Plans Picked Up 5/23/2022 APPLICANT
Plan Check Approved 9/14/2022 JOSEPH RAFOLS
Issued 9/14/2022 APPLICANT
CofO in Progress 5/4/2023 KIRK SANDERS
Permit Finaled 5/15/2023 MICHAEL SMITH
CofO Issued 5/15/2023 MICHAEL SMITH
Permit Finaled 5/15/2023 MICHAEL SMITH

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 6/2/2022 MEGAN GODINEZ
Sewer availability Cleared 6/8/2022 MEGAN GODINEZ
Specific Plan Cleared 6/13/2022 ERIN NASH
Low Impact Development Cleared 9/8/2022 SUNG JOON WON
Roof/Waste drainage to street Cleared 9/9/2022 ROMAN GUTIERREZ

Contact Information

Contractor Owner-Builder       ,
Engineer Afzal,, Behzad; Lic. No.: C79628 22 CREEK RD 52      IRVINE, CA 92604

Inspector Information

WAYNE REGESTER, (818) 374-1164 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 9/20/2022 Corrections Issued RAFAEL CORTES
Deputy Drilled-In Anchors 9/22/2022 Approved RAFAEL CORTES
Footing/Foundation/Slab 9/27/2022 Approved RAFAEL CORTES
BUILDING-Rough-Frame 11/7/2022 Partial Approval WILLIAM WREN
Floor/Roof Diaphrgm/Shear Wall 11/16/2022 Partial Approval CALEB MEISTER
PLUMBING-Rough 12/5/2022 Partial Approval ARAM AVEDISIAN
Floor/Roof Diaphrgm/Shear Wall 12/8/2022 Approved JOHN COLEMAN
PLUMBING-Rough 12/8/2022 Approved JOHN COLEMAN
Deputy Drilled-In Anchors 12/20/2022 Conditional Approval KIRK SANDERS
Deputy Wood Construction 12/20/2022 Conditional Approval KIRK SANDERS
ELECTRICAL-Rough 12/23/2022 Not Ready for Inspection DAVID ANDERSON
Floor/Roof Diaphrgm/Shear Wall 12/23/2022 Approved DAVID ANDERSON
Green Building Rough 12/23/2022 Order to Comply Issued DAVID ANDERSON
HVAC-Rough 12/23/2022 Approved DAVID ANDERSON
MERV13>=Rough 12/23/2022 Approved DAVID ANDERSON
ELECTRICAL-Rough 12/27/2022 Approved JOHN COLEMAN
ELECTRICAL-Rough 12/28/2022 No Access for Inspection JOHN COLEMAN
BUILDING-Rough-Frame 12/29/2022 Approved JOHN COLEMAN
Green Building Rough 12/29/2022 Approved JOHN COLEMAN
PLUMBING-Rough 12/29/2022 Approved JOHN COLEMAN
Wood Frame 12/29/2022 Approved JOHN COLEMAN
Interior/Exterior Lathing 12/30/2022 Corrections Issued JOHN COLEMAN
Insulation 1/31/2023 Approved DAVID MATSON
Drywall Nailing 2/9/2023 Approved KIRK SANDERS
Shower Pan 2/23/2023 Approved KIRK SANDERS
Interior/Exterior Lathing 3/2/2023 Partial Approval CHRISTOPHE COCHRAN
ELECTRICAL-Final 4/27/2023 Approved KIRK SANDERS
Final 4/27/2023 Corrections Issued KIRK SANDERS
Green Building Final 4/27/2023 Approved KIRK SANDERS
HVAC-Final 4/27/2023 Approved KIRK SANDERS
MERV13>=Final 4/27/2023 Approved KIRK SANDERS
PLUMBING-Final 4/27/2023 Approved KIRK SANDERS
SGSOV-Seismic Gas S/O Valve 4/27/2023 SGSOV Approved KIRK SANDERS
Smoke Detectors 4/27/2023 Approved KIRK SANDERS
Final 5/4/2023 OK to Issue CofO KIRK SANDERS
Pre-Inspection 5/4/2023 Approved KIRK SANDERS