19906 W WELBY WAY 91306
Certificate Information: 19906 W WELBY WAY 91306
- Application / Permit
- 22014-20000-02297
- Plan Check / Job No.
- B22VN07268
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ADDITION OF 307 SQ. FT. BEDROOM AND BATHROOM ON THE FIRST FLOOR, AND A 207 SQ. FT. TRELLIS ADDITION - ALL WORK PER ENGINEER
- Permit Issued
- Issued on 6/13/2022
- Issuing Office
- Current Status
- CofO Issued on 3/9/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 5/11/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 5/12/2022 | DANIEL ABRAMYAN |
| Corrections Issued | 5/12/2022 | DANIEL ABRAMYAN |
| Plan Check Approved | 5/12/2022 | DANIEL ABRAMYAN |
| Building Plans Picked Up | 6/2/2022 | APPLICANT |
| Issued | 6/13/2022 | APPLICANT |
| CofO in Progress | 10/7/2022 | DAVID SANDOVAL |
| Permit Finaled | 3/9/2023 | DANIEL ORRANTE |
| CofO Issued | 3/9/2023 | DANIEL ORRANTE |
| Permit Finaled | 3/9/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 5/16/2022 | JOSE DUARTE-DIAZ |
| Roof/Waste drainage to street | Cleared | 5/16/2022 | JOSE DUARTE-DIAZ |
| Sewer availability | Cleared | 5/16/2022 | JOSE DUARTE-DIAZ |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Koma,, Shahram Javadi; Lic. No.: C69497 | 23241 VENTURA BLVD 300 WOODLAND HILLS, CA 91364 |
Inspector Information
| ALEXANDER HANDY, (818) 774-4317 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 7/18/2022 | Partial Approval | STEVEN BACK |
| Footing/Foundation/Slab | 7/18/2022 | Partial Approval | STEVEN BACK |
| BUILDING-Rough-Frame | 7/28/2022 | Partial Approval | STEVEN BACK |
| PLUMBING-Rough | 7/28/2022 | Partial Approval | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 8/5/2022 | Partial Approval | STEVEN BACK |
| Floor/Roof Diaphrgm/Shear Wall | 8/16/2022 | Approved | STEVEN BACK |
| Insulation | 8/16/2022 | Not Ready for Inspection | STEVEN BACK |
| Rough-Elec/Plmb/HVAC | 8/16/2022 | Approved | STEVEN BACK |
| Insulation | 8/17/2022 | Not Ready for Inspection | STEVEN BACK |
| BUILDING-Rough-Frame | 8/19/2022 | Partial Approval | STEVEN BACK |
| Green Building Rough | 8/19/2022 | Approved | STEVEN BACK |
| Interior/Exterior Lathing | 8/19/2022 | Partial Approval | STEVEN BACK |
| Shower Pan | 8/19/2022 | Approved | STEVEN BACK |
| Insulation | 8/22/2022 | Corrections Issued | STEVEN BACK |
| Drywall Nailing | 8/24/2022 | Corrections Issued | STEVEN BACK |
| Insulation | 8/24/2022 | Corrections Issued | STEVEN BACK |
| Interior/Exterior Lathing | 8/24/2022 | Approved | STEVEN BACK |
| BUILDING-Rough-Frame | 9/14/2022 | Not Ready for Inspection | STEVEN BACK |
| Final | 9/14/2022 | Not Ready for Inspection | STEVEN BACK |
| Footing/Foundation/Slab | 9/14/2022 | Not Ready for Inspection | STEVEN BACK |
| Green Building Final | 9/14/2022 | Not Ready for Inspection | STEVEN BACK |
| SGSOV-Seismic Gas S/O Valve | 9/14/2022 | SGSOV Not Ready | STEVEN BACK |
| Smoke Detectors | 9/14/2022 | Not Ready for Inspection | STEVEN BACK |
| BUILDING-Rough-Frame | 10/6/2022 | Approved | DAVID SANDOVAL |
| ELECTRICAL-Final | 10/6/2022 | Approved | DAVID SANDOVAL |
| Final | 10/6/2022 | OK to Issue CofO | DAVID SANDOVAL |
| Footing/Foundation/Slab | 10/6/2022 | Approved | DAVID SANDOVAL |
| Green Building Final | 10/6/2022 | Approved | DAVID SANDOVAL |
| HVAC-Final | 10/6/2022 | Approved | DAVID SANDOVAL |
| PLUMBING-Final | 10/6/2022 | Approved | DAVID SANDOVAL |
| SGSOV-Seismic Gas S/O Valve | 10/6/2022 | SGSOV Approved | DAVID SANDOVAL |
| Smoke Detectors | 10/6/2022 | Approved | DAVID SANDOVAL |