15239 W OTSEGO ST 91403
Certificate Information: 15239 W OTSEGO ST 91403
- Application / Permit
- 22014-20000-01976
- Plan Check / Job No.
- B22VN06321
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT (E) DETACHED 20' 3" X 12' HOBBY ROOM AND 20' 3" X 20' 2-CAR GARAGE TO ACCESSORY DWELLING UNIT PER GCS 65852.2(e)(1)(A). ALL WORK DONE PER WFPP.
- Permit Issued
- Issued on 8/26/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 7/17/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 4/27/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 5/5/2022 | LUISANGEL VALENZUELA |
| Corrections Issued | 5/6/2022 | LUISANGEL VALENZUELA |
| Plan Check Approved | 7/29/2022 | GURUNATH NESARAJAH |
| Issued | 8/26/2022 | APPLICANT |
| CofO in Progress | 4/16/2024 | THOMAS FINNILA |
| Permit Finaled | 7/17/2024 | RUBEN SALAS |
| CofO Issued | 7/17/2024 | RUBEN SALAS |
| Permit Finaled | 7/17/2024 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 5/23/2022 | MEGAN GODINEZ |
| Roof/Waste drainage to street | Cleared | 5/23/2022 | MEGAN GODINEZ |
| Sewer availability | Cleared | 5/24/2022 | MEGAN GODINEZ |
| Construction near power lines | Cleared | 7/23/2022 | RIDWAN HARDY |
| Eng Process Fee Ord 176,300 | Cleared | 7/27/2022 | MEGAN GODINEZ |
| Public Works-Highway Ded. | Cleared | 7/27/2022 | MEGAN GODINEZ |
| Public Works-Open Permits | Cleared | 7/27/2022 | MEGAN GODINEZ |
| Public Works-Sewers | Cleared | 7/27/2022 | MEGAN GODINEZ |
Contact Information
| Contractor | R M Home Renovation And Design Inc; Lic. No.: 1059814-B | 5301 BALBOA BLVD UNIT E1 ENCINO, CA 91316 |
Inspector Information
| DAVID ANDERSON, (818) 374-1166 | Office Hours: 7:00-8:00 AM MON-FRI |
| RAUL OLAGI, (818) 374-1166 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| PLUMBING-Rough | 9/13/2022 | Not Ready for Inspection | JACK KARGODORIAN |
| Sewer | 9/13/2022 | Not Ready for Inspection | JACK KARGODORIAN |
| Deputy Drilled-In Anchors | 9/23/2022 | Partial Approval | JACK KARGODORIAN |
| Footing/Foundation/Slab | 9/23/2022 | Approved | JACK KARGODORIAN |
| PLUMBING-Rough | 9/23/2022 | Partial Approval | JACK KARGODORIAN |
| Sewer | 9/23/2022 | Approved | JACK KARGODORIAN |
| Rough-Elec/Plmb/HVAC | 8/21/2023 | Corrections Issued | THOMAS FINNILA |
| BUILDING-Rough-Frame | 11/8/2023 | Partial Approval | RUBEN SALAS |
| Floor/Roof Diaphrgm/Shear Wall | 11/8/2023 | Partial Approval | RUBEN SALAS |
| Green Building Rough | 11/8/2023 | Not Ready for Inspection | RUBEN SALAS |
| Pre-Inspection | 11/8/2023 | Partial Inspection | RUBEN SALAS |
| Rough-Elec/Plmb/HVAC | 11/8/2023 | Partial Inspection | RUBEN SALAS |
| Insulation | 12/5/2023 | Not Ready for Inspection | THOMAS FINNILA |
| Interior/Exterior Lathing | 12/5/2023 | Not Ready for Inspection | THOMAS FINNILA |
| PLUMBING-Rough | 12/5/2023 | Corrections Issued | THOMAS FINNILA |
| Deputy Drilled-In Anchors | 12/6/2023 | Conditional Approval | DAVID MATSON |
| ELECTRICAL-Rough | 12/11/2023 | Approved | THOMAS FINNILA |
| HVAC-Rough | 12/11/2023 | Approved | THOMAS FINNILA |
| PLUMBING-Rough | 12/11/2023 | Approved | THOMAS FINNILA |
| Wood Frame | 12/11/2023 | Approved | THOMAS FINNILA |
| Drywall Nailing | 12/18/2023 | Approved | THOMAS FINNILA |
| Interior/Exterior Lathing | 12/21/2023 | Not Ready for Inspection | THOMAS FINNILA |
| Shower Pan | 12/21/2023 | Corrections Issued | THOMAS FINNILA |
| Interior/Exterior Lathing | 12/22/2023 | Approved | THOMAS FINNILA |
| Shower Pan | 12/22/2023 | Approved | THOMAS FINNILA |
| ELECTRICAL-Rough | 2/15/2024 | Not Ready for Inspection | THOMAS FINNILA |
| ELECTRICAL-Final | 3/15/2024 | Not Ready for Inspection | THOMAS FINNILA |
| Final | 3/15/2024 | Not Ready for Inspection | THOMAS FINNILA |
| HVAC-Final | 3/15/2024 | Not Ready for Inspection | THOMAS FINNILA |
| PLUMBING-Final | 3/15/2024 | Not Ready for Inspection | THOMAS FINNILA |
| SGSOV-Seismic Gas S/O Valve | 3/15/2024 | SGSOV Not Ready | THOMAS FINNILA |
| BUILDING-Rough-Frame | 4/1/2024 | Approved | THOMAS FINNILA |
| ELECTRICAL-Final | 4/1/2024 | Not Ready for Inspection | THOMAS FINNILA |
| Final | 4/1/2024 | Corrections Issued | THOMAS FINNILA |
| Green Building Final | 4/1/2024 | Approved | THOMAS FINNILA |
| Green Building Rough | 4/1/2024 | Approved | THOMAS FINNILA |
| HVAC-Final | 4/1/2024 | Corrections Issued | THOMAS FINNILA |
| PLUMBING-Final | 4/1/2024 | Approved | THOMAS FINNILA |
| SGSOV-Seismic Gas S/O Valve | 4/1/2024 | SGSOV Not Ready | THOMAS FINNILA |
| Smoke Detectors | 4/1/2024 | Approved | THOMAS FINNILA |
| ELECTRICAL-Final | 4/8/2024 | Approved | THOMAS FINNILA |
| Final | 4/8/2024 | Corrections Issued | THOMAS FINNILA |
| HVAC-Final | 4/8/2024 | Approved | THOMAS FINNILA |
| PLUMBING-Final | 4/8/2024 | Approved | THOMAS FINNILA |
| SGSOV-Seismic Gas S/O Valve | 4/8/2024 | SGSOV Approved | THOMAS FINNILA |
| Enclosure/Fence | 4/10/2024 | Approved | THOMAS FINNILA |
| Final | 4/12/2024 | OK to Issue CofO | THOMAS FINNILA |
| Service/Power Release | 4/12/2024 | Approved | THOMAS FINNILA |