6252 N MARY ELLEN AVE 91401
Certificate Information: 6252 N MARY ELLEN AVE 91401
- Application / Permit
- 22014-20000-01570
- Plan Check / Job No.
- B22VN05164
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSED 35'-3.5" X 44'-2.5" IRREGULAR SHAPED ADDIITION AND MAJOR REMODEL TO (E) SFD. NFPA 13D FIRE SPRINKLERS THROUGHOUT. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 12/23/2022
- Issuing Office
- Valley
- Current Status
- CofO Issued on 5/29/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
Submitted | 4/6/2022 | APPLICANT |
Assigned to Plan Check Engineer | 5/5/2022 | RAPHAEL ROSAS |
Corrections Issued | 5/18/2022 | RAPHAEL ROSAS |
Quality Review Completed | 5/24/2022 | STEVEN KIM |
Building Plans Picked Up | 5/24/2022 | APPLICANT |
Applicant returned to address corrections | 11/7/2022 | RAPHAEL ROSAS |
Plan Check Approved | 11/21/2022 | RAPHAEL ROSAS |
Issued | 12/23/2022 | APPLICANT |
CofO in Progress | 5/10/2024 | ROBERTO PALACIOS-LOPEZ |
Permit Finaled | 5/29/2024 | RUBEN SALAS |
CofO Issued | 5/29/2024 | RUBEN SALAS |
Permit Finaled | 5/29/2024 | RUBEN SALAS |
Permit Application Clearance Information
Eng Process Fee Ord 176,300 | Cleared | 10/18/2022 | ROMAN GUTIERREZ |
Sewer availability | Cleared | 10/18/2022 | ROMAN GUTIERREZ |
Low Impact Development | Cleared | 10/24/2022 | DEBORA LEITE |
Roof/Waste drainage to street | Cleared | 10/25/2022 | MEGAN GODINEZ |
Contact Information
Contractor | Owner-Builder | , |
Engineer | Zolfaghari,, Saeed; Lic. No.: C86761 | 6201 BEE AVE AGOURA HILLS, CA 91301 |
Inspector Information
OGANES TARAKHCHYAN, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
GAREN HAYRAPETYAN, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
No Data Available. |
Inspection Request History
Pre-Inspection | 12/28/2022 | Approved | KIRK SANDERS |
PLUMBING-Rough | 1/13/2023 | Partial Approval | MISAEL ESPARZA |
Sewer | 1/18/2023 | Partial Approval | KIRK SANDERS |
Deputy Drilled-In Anchors | 1/24/2023 | Conditional Approval | MICHAEL SMITH |
Excavation/Setback/Form/Re-Bar | 1/24/2023 | Approved | KIRK SANDERS |
Footing/Foundation/Slab | 1/24/2023 | Approved | KIRK SANDERS |
Underground Mechanical | 1/24/2023 | Approved | KIRK SANDERS |
Floor/Roof Diaphrgm/Shear Wall | 2/28/2023 | Partial Approval | JAVIER RAMOS JR |
Verify Sprinkler Sign Off | 2/28/2023 | Corrections Issued | JAVIER RAMOS JR |
Floor/Roof Diaphrgm/Shear Wall | 5/4/2023 | Approved | KIRK SANDERS |
HVAC-Rough | 5/4/2023 | Corrections Issued | KIRK SANDERS |
PLUMBING-Rough | 5/4/2023 | Conditional Approval | KIRK SANDERS |
BUILDING-Rough-Frame | 5/11/2023 | Not Ready for Inspection | KIRK SANDERS |
ELECTRICAL-Rough | 5/11/2023 | Corrections Issued | KIRK SANDERS |
Green Building Rough | 5/11/2023 | Approved | KIRK SANDERS |
HVAC-Rough | 5/11/2023 | Conditional Approval | KIRK SANDERS |
PLUMBING-Rough | 5/11/2023 | Approved | KIRK SANDERS |
BUILDING-Rough-Frame | 5/30/2023 | Approved | KIRK SANDERS |
ELECTRICAL-Rough | 5/30/2023 | Conditional Approval | KIRK SANDERS |
HVAC-Rough | 5/30/2023 | Approved | KIRK SANDERS |
Interior/Exterior Lathing | 5/30/2023 | Partial Approval | KIRK SANDERS |
Insulation | 6/8/2023 | Approved | RYAN SALAZAR |
Drywall Nailing | 6/21/2023 | Approved | ROBERT GOLD |
Interior/Exterior Lathing | 6/21/2023 | Partial Approval | ROBERT GOLD |
Shower Pan | 6/21/2023 | Partial Approval | ROBERT GOLD |
Shower Pan | 7/7/2023 | Approved | KIRK SANDERS |
Sewer | 10/10/2023 | Approved | CHRISTOPHER ROJAS |
Gas Test | 3/29/2024 | Approved | JOSE AVILA |
HVAC-Final | 3/29/2024 | Corrections Issued | JOSE AVILA |
PLUMBING-Final | 3/29/2024 | Corrections Issued | JOSE AVILA |
Gas Test | 4/1/2024 | Approved | JOSE AVILA |
ELECTRICAL-Final | 4/16/2024 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
Final | 4/16/2024 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
Green Building Final | 4/16/2024 | Approved | ROBERTO PALACIOS-LOPEZ |
HVAC-Final | 4/16/2024 | Corrections Issued | ROBERTO PALACIOS-LOPEZ |
PLUMBING-Final | 4/16/2024 | Approved | ROBERTO PALACIOS-LOPEZ |
SGSOV-Seismic Gas S/O Valve | 4/16/2024 | SGSOV Approved | ROBERTO PALACIOS-LOPEZ |
Service/Power Release | 4/16/2024 | Approved | ROBERTO PALACIOS-LOPEZ |
Smoke Detectors | 4/16/2024 | Approved | ROBERTO PALACIOS-LOPEZ |
ELECTRICAL-Final | 4/24/2024 | Approved | JOSE AVILA |
Final | 4/24/2024 | Partial Approval | JOSE AVILA |
HVAC-Rough | 4/24/2024 | Approved | JOSE AVILA |
Service/Power Release | 4/24/2024 | Approved | JOSE AVILA |
Final | 5/10/2024 | OK to Issue CofO | ROBERTO PALACIOS-LOPEZ |