11221 W RUNNYMEDE ST 91352

Certificate Information: 11221 W RUNNYMEDE ST 91352

Application / Permit
22014-20000-01455
Plan Check / Job No.
B22VN04745
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
36' X 31'-7" ADDITION TO REAR OF SINGLE FAMILY DWELLING; ADD 4' X 12'-6", 14'-4" X 4'-3" TO THE FRONT OF SFD, ADD 4'-3" X 8' PORCH; INTERIOR REMODEL; EQUIPPED WITH NFPA 13-D FIRE SPRINKLERS THROUGHOUT
Permit Issued
Issued on 8/5/2022
Issuing Office
Valley
Current Status
CofO Issued on 6/6/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 3/30/2022 APPLICANT
Assigned to Plan Check Engineer 4/14/2022 SELLA BENYAMIN
Corrections Issued 4/19/2022 SELLA BENYAMIN
Quality Review Completed 4/21/2022 STEVEN KIM
Building Plans Picked Up 4/22/2022 APPLICANT
Plan Check Approved 8/5/2022 SELLA BENYAMIN
Issued 8/5/2022 APPLICANT
CofO in Progress 6/5/2023 ROBERT GOLD
Permit Finaled 6/6/2023 MICHAEL SMITH
CofO Issued 6/6/2023 MICHAEL SMITH
Permit Finaled 6/6/2023 MICHAEL SMITH

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 5/3/2022 MEGAN GODINEZ
Sewer availability Cleared 5/3/2022 MEGAN GODINEZ
Low Impact Development Cleared 7/20/2022 ANTHONY VARGAS
Roof/Waste drainage to street Cleared 7/21/2022 MEGAN GODINEZ

Contact Information

Contractor Owner-Builder       ,
Engineer Maalouf,, Sami; Lic. No.: C53210 15445 VENTURA BLVD STE 367      SHERMAN OAKS, CA 91403

Inspector Information

GAREN HAYRAPETYAN, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI
ROBERTO PALACIOS-LOPEZ, (818) 374-1171 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 9/21/2022 Approved JOHN HAYES
PLUMBING-Rough 9/29/2022 Partial Approval DEANDRE HOFFMAN
Insulation 10/5/2022 Corrections Issued ALAN MORELOS
Floor/Roof Diaphrgm/Shear Wall 10/12/2022 Not Ready for Inspection JOHN HAYES
Insulation 10/14/2022 Partial Approval CALEB MEISTER
Floor/Roof Diaphrgm/Shear Wall 11/4/2022 Partial Approval JOHN HAYES
Underground Mechanical 11/4/2022 Partial Approval JOHN HAYES
Floor/Roof Diaphrgm/Shear Wall 11/14/2022 Partial Approval JOHN HAYES
Interior/Exterior Lathing 11/14/2022 Partial Approval JOHN HAYES
Rough-Elec/Plmb/HVAC 11/18/2022 Approved CALEB MEISTER
Insulation 11/23/2022 Approved JORDAN KUTZLY
Drywall Nailing 12/5/2022 Approved JORDAN KUTZLY
Shower Pan 12/5/2022 Approved JORDAN KUTZLY
Interior/Exterior Lathing 12/13/2022 Approved JOHN HAYES
BUILDING-Rough-Frame 3/8/2023 Approved JOHN HAYES
Final 3/8/2023 Corrections Issued JOHN HAYES
Footing/Foundation/Slab 3/8/2023 Approved JOHN HAYES
Green Building Final 3/8/2023 Approved JOHN HAYES
Green Building Rough 3/8/2023 Approved JOHN HAYES
SGSOV-Seismic Gas S/O Valve 3/8/2023 SGSOV Approved JOHN HAYES
Smoke Detectors 3/8/2023 Approved JOHN HAYES
Final 5/9/2023 Corrections Issued JOHN HAYES
Final 5/19/2023 Corrections Issued JOHN HAYES
Final 5/26/2023 Corrections Issued ROBERT GOLD
Final 6/5/2023 OK to Issue CofO ROBERT GOLD