6863 N HAZELTINE AVE 91405

Certificate Information: 6863 N HAZELTINE AVE 91405

Application / Permit
22014-20000-01426
Plan Check / Job No.
B22VN04661
Group
Building
Type
Bldg-Alter/Repair
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Accessory Dwelling Unit
Work Description
CONVERT REC ROOM TO ADU PER LAMC 12.22 A.33(c) and (e)
Permit Issued
Issued on 10/21/2022
Issuing Office
Metro
Current Status
Issued on 10/21/2022
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 3/29/2022 APPLICANT
Assigned to Plan Check Engineer 4/7/2022 SINA KHOSRAVI
Corrections Issued 4/12/2022 SINA KHOSRAVI
Quality Review Completed 4/18/2022 CHARLES CHANG
Building Plans Picked Up 4/27/2022 APPLICANT
Plan Check Approved 10/21/2022 SINA KHOSRAVI
Issued 10/21/2022 APPLICANT

Permit Application Clearance Information

Address approval Cleared 8/26/2022 LEE GUILBEAUX
Eng Process Fee Ord 176,300 Cleared 8/29/2022 LEE GUILBEAUX
Low Impact Development Cleared 8/29/2022 CHRIS VONG
Roof/Waste drainage to street Cleared 8/29/2022 LEE GUILBEAUX
Sewer availability Cleared 8/29/2022 LEE GUILBEAUX
Tenant Habitability Plan Cleared 10/14/2022 ISMAEL HERNANDEZ

Contact Information

Contractor Owner-Builder       ,
Engineer Mejia,, Fernando Finuliar; Lic. No.: C54382 8305 DUCOR AVE      WEST HILLS, CA 91304

Inspector Information

JOSE AVILA, (818) 374-1173 Office Hours: 7:00-8:00 AM MON-FRI
VINCENT HANLEY, (818) 374-1173 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Footing/Foundation/Slab 3/28/2023 Corrections Issued MICHEL ABAJAN
ELECTRICAL-Rough 5/2/2023 Corrections Issued RYAN SALAZAR
Floor/Roof Diaphrgm/Shear Wall 5/2/2023 Corrections Issued RYAN SALAZAR
HVAC-Rough 5/2/2023 Corrections Issued RYAN SALAZAR
Floor/Roof Diaphrgm/Shear Wall 5/12/2023 Approved RYAN SALAZAR
Insulation 5/12/2023 Approved RYAN SALAZAR
Interior/Exterior Lathing 5/12/2023 Not Ready for Inspection RYAN SALAZAR
Shower Pan 5/12/2023 Approved RYAN SALAZAR
Drywall Nailing 5/22/2023 Approved RYAN SALAZAR
ELECTRICAL-Rough 5/22/2023 Approved RYAN SALAZAR
Footing/Foundation/Slab 5/22/2023 Approved RYAN SALAZAR
Green Building Rough 5/22/2023 Approved RYAN SALAZAR
HVAC-Rough 5/22/2023 Approved RYAN SALAZAR
Interior/Exterior Lathing 5/22/2023 Partial Approval RYAN SALAZAR
PLUMBING-Rough 5/22/2023 Approved RYAN SALAZAR
Interior/Exterior Lathing 6/1/2023 Approved RYAN SALAZAR
BUILDING-Rough-Frame 6/30/2023 Approved RYAN SALAZAR
Final 6/30/2023 Corrections Issued RYAN SALAZAR
Green Building Final 6/30/2023 Not Ready for Inspection RYAN SALAZAR
SGSOV-Seismic Gas S/O Valve 6/30/2023 SGSOV Not Ready RYAN SALAZAR
Smoke Detectors 6/30/2023 Approved RYAN SALAZAR
Final 7/10/2023 Not Ready for Inspection RYAN SALAZAR
Green Building Final 7/10/2023 Approved RYAN SALAZAR
SGSOV-Seismic Gas S/O Valve 7/10/2023 SGSOV Approved RYAN SALAZAR
Final 10/13/2023 Not Ready for Inspection RYAN SALAZAR
Special/Order Compliance 10/18/2024 Partial Inspection RYAN SALAZAR
PLUMBING-Final 2/20/2025 Approved RYAN SALAZAR