5250 N IRVINE AVE 91601

Certificate Information: 5250 N IRVINE AVE 91601

Application / Permit
22014-20000-01386
Plan Check / Job No.
B22VN04511
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
REMODEL, 1ST AND 2ND STORY ADDITION TO (E) SFD - 1 OF 2
Permit Issued
Issued on 11/22/2023
Issuing Office
Valley
Current Status
Issued on 11/22/2023
Certificate of Occupancy
Pending More Information

Permit Application Status History

Submitted 3/24/2022 APPLICANT
Assigned to Plan Check Engineer 4/21/2022 ADRIANA LOPEZ
Corrections Issued 5/4/2022 ADRIANA LOPEZ
Quality Review Completed 5/12/2022 KEN GILL
Building Plans Picked Up 5/16/2022 APPLICANT
Applicant returned to address corrections 12/1/2022 ADRIANA LOPEZ
Plan Check Approved 1/3/2023 ADRIANA LOPEZ
No Progress 7/11/2023 ADRIANA LOPEZ
Plan Check Approved 7/11/2023 ADRIANA LOPEZ
Issued 11/22/2023 APPLICANT

Permit Application Clearance Information

Eng Process Fee Ord 176,300 Cleared 7/15/2022 LEE GUILBEAUX
Low Impact Development Cleared 10/21/2022 ERNEST TSE
Roof/Waste drainage to street Cleared 10/25/2022 ROMAN GUTIERREZ
Public Works-Highway Ded. Cleared 10/25/2022 ROMAN GUTIERREZ
Public Works-Open Permits Cleared 10/25/2022 ROMAN GUTIERREZ
Public Works-Sewers Cleared 10/25/2022 ROMAN GUTIERREZ
ZI Cleared 11/2/2022 CHRISTIAN PEARSON

Contact Information

Contractor Owner-Builder       ,
Engineer Standley,, Craig Erick; Lic. No.: C87675 60 VIA CARATAMA      SAN CLEMENTE, CA 92673

Inspector Information

JAVIER RAMOS JR, (818) 374-1163 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 12/12/2023 Corrections Issued KIRK SANDERS
Footing/Foundation/Slab 12/12/2023 Not Ready for Inspection KIRK SANDERS
Excavation/Setback/Form/Re-Bar 12/18/2023 Approved KIRK SANDERS
Footing/Foundation/Slab 12/18/2023 Approved KIRK SANDERS
BUILDING-Rough-Frame 12/29/2023 Corrections Issued KIRK SANDERS
Green Building Rough 12/29/2023 Not Ready for Inspection KIRK SANDERS
MERV13>=Rough 12/29/2023 Not Ready for Inspection KIRK SANDERS
PLUMBING-Rough 12/29/2023 Not Ready for Inspection KIRK SANDERS
Sewer 12/29/2023 Not Ready for Inspection KIRK SANDERS
PLUMBING-Rough 1/2/2024 Partial Approval KIRK SANDERS
SGSOV-Seismic Gas S/O Valve 1/2/2024 SGSOV Not Ready KIRK SANDERS
Sewer 1/2/2024 Partial Approval KIRK SANDERS
Underground Mechanical 1/2/2024 Partial Approval KIRK SANDERS
Wood Frame 1/2/2024 Corrections Issued KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 1/5/2024 Partial Approval KIRK SANDERS
Insulation 1/5/2024 Partial Approval KIRK SANDERS
Deputy Steel/Welding 1/8/2024 Conditional Approval JUAN VALENZUELA
Floor/Roof Diaphrgm/Shear Wall 1/31/2024 Corrections Issued KIRK SANDERS
Structural Steel Frame 1/31/2024 Partial Approval KIRK SANDERS
ELECTRICAL-Rough 2/6/2024 Approved KIRK SANDERS
Floor/Roof Diaphrgm/Shear Wall 2/6/2024 Approved KIRK SANDERS
PLUMBING-Rough 2/6/2024 Approved KIRK SANDERS
BUILDING-Rough-Frame 2/28/2024 Corrections Issued KIRK SANDERS
Footing/Foundation/Slab 2/28/2024 Approved KIRK SANDERS
HVAC-Rough 2/28/2024 Approved KIRK SANDERS
Structural Steel Frame 2/28/2024 Approved KIRK SANDERS
Insulation 3/7/2024 Approved KIRK SANDERS
Interior/Exterior Lathing 3/7/2024 Partial Approval KIRK SANDERS
Drywall Nailing 3/15/2024 Approved THOMAS FINNILA
Green Building Rough 3/15/2024 Approved THOMAS FINNILA
Shower Pan 3/15/2024 Approved THOMAS FINNILA
BUILDING-Rough-Frame 3/20/2024 Approved KIRK SANDERS
Interior/Exterior Lathing 3/20/2024 Approved KIRK SANDERS
MERV13>=Rough 3/20/2024 Approved KIRK SANDERS
ELECTRICAL-Final 8/7/2024 Not Ready for Inspection CHRISTOPHER ROJAS
Final 8/7/2024 Corrections Issued CHRISTOPHER ROJAS
Green Building Final 8/7/2024 Not Ready for Inspection CHRISTOPHER ROJAS
HVAC-Final 8/7/2024 Not Ready for Inspection CHRISTOPHER ROJAS
MERV13>=Final 8/7/2024 Not Ready for Inspection CHRISTOPHER ROJAS
PLUMBING-Final 8/7/2024 Approved CHRISTOPHER ROJAS
SGSOV-Seismic Gas S/O Valve 8/7/2024 SGSOV Approved CHRISTOPHER ROJAS
Smoke Detectors 8/7/2024 Approved CHRISTOPHER ROJAS
Final 2/23/2026 No Access for Inspection JAVIER RAMOS JR
Green Building Final 2/23/2026 No Access for Inspection JAVIER RAMOS JR
MERV13>=Final 2/23/2026 No Access for Inspection JAVIER RAMOS JR
ELECTRICAL-Final 4/7/2026 Approved JAVIER RAMOS JR
Final 4/7/2026 Corrections Issued JAVIER RAMOS JR
Green Building Final 4/7/2026 Approved JAVIER RAMOS JR
HVAC-Final 4/7/2026 Approved JAVIER RAMOS JR
MERV13>=Final 4/7/2026 Approved JAVIER RAMOS JR