15434 W VISTA HAVEN PL 91403

Certificate Information: 15434 W VISTA HAVEN PL 91403

Application / Permit
22014-20000-00794
Plan Check / Job No.
B22VN02698
Group
Building
Type
Bldg-Addition
Sub-Type
1 or 2 Family Dwelling
Primary Use
(1) Dwelling - Single Family
Work Description
ADD (39'-6"x 18'-10") IRR SHAPE AT REAR, EXPAND (15'-7"x 2'-5") AT FRONT BEDROOM & ADD/ CONNECT ( 18'-3"x 17'-0") MAIDS ROOM @ (E) DET. GARAGE AND MAJOR REMODEL TO (E) ONE STORY SINGLE FAMILY DWELLING, WITH NFPA-13D FIRE SPRINKLER THROUGHOUT. WORK PER ENGINEER.
Permit Issued
Issued on 5/3/2022
Issuing Office
Current Status
CofO Issued on 7/28/2023
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/22/2022 APPLICANT
Assigned to Plan Check Engineer 3/3/2022 TROY DEGUZMAN
Corrections Issued 3/8/2022 TROY DEGUZMAN
Quality Review Completed 3/10/2022 OMID HEDAYAT
Building Plans Picked Up 3/10/2022 APPLICANT
Applicant returned to address corrections 4/26/2022 TROY DEGUZMAN
Plan Check Approved 5/3/2022 TROY DEGUZMAN
Issued 5/3/2022 APPLICANT
CofO in Progress 7/5/2023 THOMAS FINNILA
Permit Finaled 7/28/2023 RUBEN SALAS
CofO Issued 7/28/2023 RUBEN SALAS
Permit Finaled 7/28/2023 RUBEN SALAS

Permit Application Clearance Information

GPI Written Notices Cleared 3/6/2022 TIMOTHY POWELL
Grading Pre-Inspection Cleared 3/6/2022 TIMOTHY POWELL
Address approval Cleared 3/7/2022 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 3/7/2022 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 3/7/2022 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 3/7/2022 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 3/7/2022 CARLOS AGUILERA
Eng Process Fee Ord 176,300 Cleared 3/8/2022 CARLOS AGUILERA
Sewer availability Cleared 3/8/2022 CARLOS AGUILERA
BHO/Hillside ordinance Cleared 3/17/2022 CARLOS AGUILERA
Specific Plan Cleared 4/5/2022 OLGA AYALA
ZI Cleared 4/5/2022 OLGA AYALA
Low Impact Development Cleared 4/14/2022 ANDRES COVARRUBIAS
Roof/Waste drainage to street Cleared 4/19/2022 ABDULLAH SADOZAI
Hydrant and Access approval Cleared 4/22/2022 KURT CORRAL
Green Code Cleared 4/26/2022 TROY DEGUZMAN

Contact Information

Contractor Classic Remodeling; Lic. No.: 980373-B 12830 BURBANK BLVD #317      NORTH HOLLYWOOD, CA 91607
Engineer Barakat,, Fouad Chafic; Lic. No.: C67449 11 CEDARWOOD DR      POMONA, CA 91766

Inspector Information

DAVID ANDERSON, (818) 374-1166 Office Hours: 7:00-8:00 AM MON-FRI
RAUL OLAGI, (818) 374-1166 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Underground Mechanical 5/24/2022 Partial Approval JACK KARGODORIAN
Deputy Drilled-In Anchors 5/26/2022 Partial Approval JACK KARGODORIAN
Excavation/Setback/Form/Re-Bar 5/31/2022 Not Ready for Inspection JACK KARGODORIAN
Underground Mechanical 5/31/2022 Partial Approval JACK KARGODORIAN
Footing/Foundation/Slab 6/6/2022 Corrections Issued MATT KELLERMAN
Footing/Foundation/Slab 6/10/2022 No Access for Inspection JACK KARGODORIAN
Footing/Foundation/Slab 6/16/2022 Approved JACK KARGODORIAN
Rough-Elec/Plmb/HVAC 8/30/2022 Approved JACK KARGODORIAN
Deputy Steel/Welding 9/14/2022 Partial Approval JACK KARGODORIAN
Wood Frame 9/22/2022 Corrections Issued JACK KARGODORIAN
BUILDING-Rough-Frame 10/14/2022 Corrections Issued THOMAS FINNILA
Interior/Exterior Lathing 10/14/2022 Not Ready for Inspection THOMAS FINNILA
Verify Sprinkler Sign Off 10/14/2022 Not Ready for Inspection THOMAS FINNILA
Interior/Exterior Lathing 10/20/2022 Not Ready for Inspection THOMAS FINNILA
Wood Frame 10/20/2022 Conditional Approval THOMAS FINNILA
BUILDING-Rough-Frame 10/26/2022 Approved THOMAS FINNILA
Green Building Rough 10/26/2022 Approved THOMAS FINNILA
Insulation 10/26/2022 Approved THOMAS FINNILA
Interior/Exterior Lathing 10/26/2022 Not Ready for Inspection THOMAS FINNILA
MERV13>=Rough 10/26/2022 Approved THOMAS FINNILA
Shower Pan 10/26/2022 Not Ready for Inspection THOMAS FINNILA
Verify Sprinkler Sign Off 10/26/2022 Approved THOMAS FINNILA
Drywall Nailing 11/1/2022 Partial Approval THOMAS FINNILA
Interior/Exterior Lathing 11/1/2022 Approved THOMAS FINNILA
Shower Pan 11/1/2022 Approved THOMAS FINNILA
ELECTRICAL-Final 3/17/2023 Corrections Issued THOMAS FINNILA
SGSOV-Seismic Gas S/O Valve 3/17/2023 SGSOV Not Ready THOMAS FINNILA
Smoke Detectors 3/17/2023 Approved THOMAS FINNILA
Drywall Nailing 6/21/2023 Approved THOMAS FINNILA
ELECTRICAL-Final 6/21/2023 Approved THOMAS FINNILA
HVAC-Final 6/21/2023 Approved THOMAS FINNILA
MERV13>=Final 6/21/2023 Approved THOMAS FINNILA
PLUMBING-Final 6/21/2023 Approved THOMAS FINNILA
Final 7/3/2023 OK to Issue CofO THOMAS FINNILA
Green Building Final 7/3/2023 Approved THOMAS FINNILA
SGSOV-Seismic Gas S/O Valve 7/3/2023 SGSOV Approved THOMAS FINNILA