12144 W OTSEGO ST 91607
Certificate Information: 12144 W OTSEGO ST 91607
- Application / Permit
- 22014-20000-00174
- Plan Check / Job No.
- B22VN00624
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- PROPOSED 20'-10" X 29'-10" IRREGULAR SHAPED ADDITION AND REMODEL AND ADD 7'-2" X 15' FRONT PORCH TO (E) SFD. ALL WORK PER ENGINEERING.
- Permit Issued
- Issued on 3/8/2023
- Issuing Office
- Valley
- Current Status
- CofO Issued on 12/12/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 1/14/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/28/2022 | RAPHAEL ROSAS |
| Corrections Issued | 1/29/2022 | RAPHAEL ROSAS |
| Building Plans Picked Up | 2/1/2022 | APPLICANT |
| Plan Check Approved | 8/23/2022 | ANGELICA MARTINEZ |
| Issued | 3/8/2023 | APPLICANT |
| CofO in Progress | 11/27/2023 | KIRK SANDERS |
| Permit Finaled | 12/12/2023 | RUBEN SALAS |
| CofO Issued | 12/12/2023 | RUBEN SALAS |
| Permit Finaled | 12/12/2023 | RUBEN SALAS |
Permit Application Clearance Information
| Specific Plan | Cleared | 2/4/2022 | CORREY KITCHENS |
| ZI | Cleared | 2/4/2022 | CORREY KITCHENS |
| ZI | Cleared | 2/4/2022 | CORREY KITCHENS |
| Eng Process Fee Ord 176,300 | Cleared | 4/8/2022 | LEE GUILBEAUX |
| Sewer availability | Cleared | 4/8/2022 | LEE GUILBEAUX |
| Low Impact Development | Cleared | 8/4/2022 | SARAH YOUSSEF |
| Roof/Waste drainage to street | Cleared | 8/11/2022 | LEE GUILBEAUX |
Contact Information
| Contractor | C S H Properties Inc; Lic. No.: 951406-B | 4334 LEMP AVE STUDIO CITY, CA 91604 |
| Engineer | Tan,, Henreik Steven; Lic. No.: C65723 | 5100 LLANO DRIVE WOODLAND HILLS, CA 91364 |
Inspector Information
| WAYNE REGESTER, (818) 374-1164 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 5/8/2023 | Approved | KIRK SANDERS |
| Pre-Inspection | 5/8/2023 | Approved | KIRK SANDERS |
| Underground Mechanical | 5/8/2023 | Not Ready for Inspection | KIRK SANDERS |
| BUILDING-Rough-Frame | 5/24/2023 | Partial Approval | KIRK SANDERS |
| ELECTRICAL-Rough | 5/24/2023 | Partial Approval | KIRK SANDERS |
| PLUMBING-Rough | 5/24/2023 | Partial Approval | KIRK SANDERS |
| Pre-Inspection | 5/24/2023 | Approved | KIRK SANDERS |
| BUILDING-Rough-Frame | 5/31/2023 | Partial Approval | KIRK SANDERS |
| Insulation | 5/31/2023 | Partial Approval | KIRK SANDERS |
| PLUMBING-Rough | 5/31/2023 | Partial Approval | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 6/6/2023 | Partial Approval | KIRK SANDERS |
| Footing/Foundation/Slab | 6/6/2023 | Corrections Issued | KIRK SANDERS |
| Pre-Inspection | 6/8/2023 | Approved | JOHN COLEMAN |
| Wood Frame | 6/8/2023 | Not Ready for Inspection | JOHN COLEMAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/5/2023 | Partial Approval | KIRK SANDERS |
| Footing/Foundation/Slab | 7/5/2023 | Approved | KIRK SANDERS |
| Interior/Exterior Lathing | 7/5/2023 | Not Ready for Inspection | KIRK SANDERS |
| Pre-Inspection | 7/5/2023 | Approved | KIRK SANDERS |
| Wood Frame | 7/5/2023 | Not Ready for Inspection | KIRK SANDERS |
| ELECTRICAL-Rough | 7/6/2023 | Partial Approval | KIRK SANDERS |
| HVAC-Rough | 7/6/2023 | Corrections Issued | KIRK SANDERS |
| PLUMBING-Rough | 7/6/2023 | Approved | KIRK SANDERS |
| Pre-Inspection | 7/6/2023 | Approved | KIRK SANDERS |
| BUILDING-Rough-Frame | 7/11/2023 | Partial Approval | KIRK SANDERS |
| ELECTRICAL-Rough | 7/11/2023 | Approved | KIRK SANDERS |
| HVAC-Rough | 7/11/2023 | Approved | KIRK SANDERS |
| Interior/Exterior Lathing | 7/11/2023 | Not Ready for Inspection | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 7/14/2023 | Not Ready for Inspection | KIRK SANDERS |
| Interior/Exterior Lathing | 7/14/2023 | Not Ready for Inspection | KIRK SANDERS |
| Pre-Inspection | 7/14/2023 | Not Ready for Inspection | KIRK SANDERS |
| Wood Frame | 7/14/2023 | Not Ready for Inspection | KIRK SANDERS |
| BUILDING-Rough-Frame | 7/17/2023 | Partial Approval | KIRK SANDERS |
| Interior/Exterior Lathing | 7/17/2023 | Partial Approval | KIRK SANDERS |
| BUILDING-Rough-Frame | 7/20/2023 | Partial Approval | KIRK SANDERS |
| Green Building Rough | 7/20/2023 | Approved | KIRK SANDERS |
| BUILDING-Rough-Frame | 7/26/2023 | Approved | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 7/26/2023 | Approved | KIRK SANDERS |
| Insulation | 7/26/2023 | Approved | KIRK SANDERS |
| Drywall Nailing | 8/2/2023 | Approved | KIRK SANDERS |
| Interior/Exterior Lathing | 8/21/2023 | Approved | KIRK SANDERS |
| Gas Test | 9/15/2023 | Approved | KIRK SANDERS |
| Pre-Inspection | 9/15/2023 | Approved | KIRK SANDERS |
| Final | 9/27/2023 | Corrections Issued | CHRISTOPHER ROJAS |
| Green Building Final | 9/27/2023 | Approved | CHRISTOPHER ROJAS |
| Pre-Inspection | 9/27/2023 | Approved | CHRISTOPHER ROJAS |
| SGSOV-Seismic Gas S/O Valve | 9/27/2023 | SGSOV Approved | CHRISTOPHER ROJAS |
| Smoke Detectors | 9/27/2023 | Approved | CHRISTOPHER ROJAS |
| Final | 10/17/2023 | OK to Issue CofO | KIRK SANDERS |