3937 N TOLAND WAY 90065
Certificate Information: 3937 N TOLAND WAY 90065
- Application / Permit
- 22014-10000-06310
- Plan Check / Job No.
- B22LA26285
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePlan Addition and remodel (E) SFD. Per engineering design.
- Permit Issued
- Issued on 1/4/2024
- Issuing Office
- Current Status
- Issued on 1/4/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/29/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/6/2023 | ALFREDO JARA |
| Corrections Issued | 1/7/2023 | ALFREDO JARA |
| Applicant returned to address corrections | 6/21/2023 | ALFREDO JARA |
| Plan Check Approved | 9/27/2023 | ALFREDO JARA |
| Issued | 1/4/2024 | APPLICANT |
Permit Application Clearance Information
| Roof/Waste drainage to street | Cleared | 3/15/2023 | STEVE MELGAR |
| Sewer availability | Cleared | 3/15/2023 | STEVE MELGAR |
| Eng Process Fee Ord 176,300 | Cleared | 3/20/2023 | STEVE MELGAR |
| Grading Pre-Inspection | Cleared | 6/22/2023 | ALFREDO JARA |
| Low Impact Development (LID) | Cleared | 9/13/2023 | VICTOR MENDOZA |
| Specific Plan | Cleared | 9/25/2023 | DAVID URITA |
| ZI | Cleared | 9/25/2023 | DAVID URITA |
Contact Information
| Architect | Chang,, Monica K; Lic. No.: NA37524 | , |
| Contractor | C M J Construction Inc; Lic. No.: 1095617-B | , |
| Engineer | Youm,, Moung Han; Lic. No.: C74086 | 309 S BERENDO ST APT 6 LOS ANGELES, CA 90020 |
Inspector Information
| NICHOLAS LOPEZ, (213) 202-3224 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 1/29/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| Deputy Drilled-In Anchors | 1/30/2024 | Conditional Approval | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 3/8/2024 | Not Ready for Inspection | BRIAN SULLIVAN |
| Piling/Pier/Caisson | 3/8/2024 | Corrections Issued | BRIAN SULLIVAN |
| Footing/Foundation/Slab | 3/15/2024 | Corrections Issued | HAMIK HARTOUNIAN |
| Piling/Pier/Caisson | 3/15/2024 | Not Ready for Inspection | HAMIK HARTOUNIAN |
| Footing/Foundation/Slab | 6/7/2024 | Not Ready for Inspection | THOMAS LOGRASSO |
| Footing/Foundation/Slab | 6/20/2024 | Approved | BRIAN SULLIVAN |
| Piling/Pier/Caisson | 6/20/2024 | Approved | BRIAN SULLIVAN |
| Floor/Roof Diaphrgm/Shear Wall | 7/10/2024 | Conditional Approval | THOMAS LOGRASSO |
| PLUMBING-Rough | 7/10/2024 | Partial Approval | THOMAS LOGRASSO |
| Deputy Wood Construction | 8/5/2024 | Conditional Approval | THOMAS LOGRASSO |
| ELECTRICAL-Rough | 12/4/2024 | No Access for Inspection | THOMAS LOGRASSO |
| Deputy Wood Construction | 1/2/2025 | Conditional Approval | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 1/3/2025 | Corrections Issued | THOMAS LOGRASSO |
| Rough-Elec/Plmb/HVAC | 1/3/2025 | Corrections Issued | THOMAS LOGRASSO |
| BUILDING-Rough-Frame | 5/9/2025 | No Access for Inspection | NICHOLAS LOPEZ |
| ELECTRICAL-Rough | 5/9/2025 | No Access for Inspection | NICHOLAS LOPEZ |
| MERV13>=Rough | 5/9/2025 | No Access for Inspection | NICHOLAS LOPEZ |
| PLUMBING-Rough | 5/9/2025 | No Access for Inspection | NICHOLAS LOPEZ |
| BUILDING-Rough-Frame | 5/21/2025 | Approved | NICHOLAS LOPEZ |
| MERV13>=Rough | 5/21/2025 | Approved | NICHOLAS LOPEZ |
| Rough-Elec/Plmb/HVAC | 5/21/2025 | Approved | NICHOLAS LOPEZ |
| Shower Pan | 10/20/2025 | Approved | REGINA MENDEZ |
| Interior/Exterior Lathing | 12/11/2025 | Approved | NICHOLAS LOPEZ |
| Insulation | 12/19/2025 | Partial Inspection | RONNIE MEDINA |
| Insulation | 4/22/2026 | Approved | LILIANA PORTILLO |
| Drywall Nailing | 5/7/2026 | Approved | NICHOLAS LOPEZ |
| Special/Order Compliance | 5/7/2026 | Corrections Issued | NICHOLAS LOPEZ |