1245 E PRESTON WAY 90291
Certificate Information: 1245 E PRESTON WAY 90291
- Application / Permit
- 22014-10000-06225
- Plan Check / Job No.
- B22LA25933
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePLAN. NEW ADDITION TO (E) SINGLE FAMILY DWELLING. This project consists of the design of a second floor addition for an existing one-story single-family residence. The addition will include new bedrooms, bathrooms, a laundry room, a stairway, sauna, pool shower and firepit. The existing kitchen, dining area and laundry room will be reconfigured to expand the kitchen work area, and to provide a storage pantry. ***BLDG REQUIRED TO BE SPRINKLERED PER NFPA 13D***
- Permit Issued
- Issued on 11/17/2023
- Issuing Office
- Current Status
- CofO Issued on 6/10/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 12/22/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/27/2023 | MICHAEL LOPEZ |
| Corrections Issued | 2/7/2023 | MICHAEL LOPEZ |
| Quality Review Completed | 2/16/2023 | TEODORO DIAZ RODRIGUEZ |
| Applicant returned to address corrections | 6/7/2023 | MICHAEL LOPEZ |
| Applicant returned to address corrections | 10/20/2023 | MICHAEL LOPEZ |
| Plan Check Approved | 11/14/2023 | MICHAEL LOPEZ |
| No Progress | 11/15/2023 | MICHAEL LOPEZ |
| Plan Check Approved | 11/15/2023 | MICHAEL LOPEZ |
| Issued | 11/17/2023 | APPLICANT |
| CofO in Progress | 5/30/2025 | JESUS RODRIGUEZ |
| Permit Finaled | 6/10/2025 | RICHARD STEINBACH |
| CofO Issued | 6/10/2025 | RICHARD STEINBACH |
| Permit Finaled | 6/10/2025 | RICHARD STEINBACH |
Permit Application Clearance Information
| Grading Pre-Inspection | Cleared | 4/3/2023 | KIRK LINKLATER |
| ZA Case | Cleared | 4/4/2023 | MARITZA PRZEKOP |
| Sewer availability | Cleared | 4/12/2023 | JASON NG |
| Hydrant and Access approval | Cleared | 4/14/2023 | KURT CORRAL |
| Eng Process Fee Ord 176,300 | Cleared | 4/17/2023 | JASON NG |
| Specific Plan | Cleared | 7/21/2023 | EDUARDO HERMOSO |
| Low Impact Development | Cleared | 9/8/2023 | TOMMY YIN |
| Roof/Waste drainage to street | Cleared | 9/27/2023 | DARIN LAM |
| GPI Written Notices | Cleared | 11/7/2023 | MATTHEW JENKINS |
Contact Information
| Architect | Ferrin,, David E; Lic. No.: C28599 | 275 SAN CLEMENTE STREET VENTURA, CA 93001 |
| Contractor | Owner-Builder | , |
| Engineer | Lubberts,, Jeffrey Scott; Lic. No.: S6432 | 1548 KIRK AVE THOUSAND OAKS, CA 91360 |
Inspector Information
| RUBEN RIVAS, (310) 914-3981 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 12/5/2023 | Conditional Approval | HERBERT GIRON |
| Footing/Foundation/Slab | 12/13/2023 | Approved | HERBERT GIRON |
| Deputy Reinf. Concrete | 12/18/2023 | Conditional Approval | HERBERT GIRON |
| BUILDING-Rough-Frame | 1/5/2024 | Partial Approval | HERBERT GIRON |
| PLUMBING-Rough | 1/5/2024 | Partial Approval | HERBERT GIRON |
| Deputy Steel/Welding | 1/16/2024 | Conditional Approval | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 2/8/2024 | Partial Approval | HERBERT GIRON |
| Deputy Steel/Welding | 2/21/2024 | Conditional Approval | HERBERT GIRON |
| ELECTRICAL-Rough | 6/24/2024 | Corrections Issued | HERBERT GIRON |
| PLUMBING-Rough | 6/24/2024 | Corrections Issued | HERBERT GIRON |
| Deputy Wood Construction | 6/25/2024 | Conditional Approval | HERBERT GIRON |
| ELECTRICAL-Rough | 6/28/2024 | Approved | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 6/28/2024 | Corrections Issued | HERBERT GIRON |
| HVAC-Rough | 6/28/2024 | Corrections Issued | HERBERT GIRON |
| Deputy Wood Construction | 7/17/2024 | Conditional Approval | HERBERT GIRON |
| Interior/Exterior Lathing | 7/18/2024 | Partial Approval | HERBERT GIRON |
| Floor/Roof Diaphrgm/Shear Wall | 8/8/2024 | Conditional Approval | HERBERT GIRON |
| HVAC-Rough | 8/8/2024 | Corrections Issued | HERBERT GIRON |
| BUILDING-Rough-Frame | 8/12/2024 | Corrections Issued | TEMISTOCLES CAAL |
| Green Building Rough | 8/12/2024 | Corrections Issued | TEMISTOCLES CAAL |
| HVAC-Rough | 8/12/2024 | Approved | TEMISTOCLES CAAL |
| BUILDING-Rough-Frame | 9/4/2024 | Approved | HERBERT GIRON |
| Green Building Rough | 9/4/2024 | Approved | HERBERT GIRON |
| Verify Sprinkler Sign Off | 9/4/2024 | Approved | HERBERT GIRON |
| Wood Frame | 9/4/2024 | Approved | HERBERT GIRON |
| Insulation | 9/12/2024 | Approved | HERBERT GIRON |
| Drywall Nailing | 9/25/2024 | Approved | HERBERT GIRON |
| Shower Pan | 12/4/2024 | Approved | REGINA MENDEZ |
| Interior/Exterior Lathing | 12/10/2024 | Approved | BOBBY KEY |
| ELECTRICAL-Final | 4/16/2025 | Corrections Issued | JESUS RODRIGUEZ |
| Final | 4/16/2025 | Corrections Issued | JESUS RODRIGUEZ |
| Green Building Final | 4/16/2025 | Approved | JESUS RODRIGUEZ |
| HVAC-Final | 4/16/2025 | Corrections Issued | JESUS RODRIGUEZ |
| PLUMBING-Final | 4/16/2025 | Approved | JESUS RODRIGUEZ |
| SGSOV-Seismic Gas S/O Valve | 4/16/2025 | SGSOV Not Ready | JESUS RODRIGUEZ |
| Smoke Detectors | 4/16/2025 | Approved | JESUS RODRIGUEZ |
| ELECTRICAL-Final | 5/29/2025 | Approved | JESUS RODRIGUEZ |
| Final | 5/29/2025 | OK to Issue CofO | JESUS RODRIGUEZ |
| HVAC-Final | 5/29/2025 | Approved | JESUS RODRIGUEZ |
| SGSOV-Seismic Gas S/O Valve | 5/29/2025 | SGSOV Approved | JESUS RODRIGUEZ |