4601 W DON QUIXOTE DR 90008
Certificate Information: 4601 W DON QUIXOTE DR 90008
- Application / Permit
- 22014-10000-03732
- Plan Check / Job No.
- B22LA14538
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- *EPLAN* ADDITION (588 SF) TO (E) 1-STORY SFD (2002 SF) AND REMODEL. PORTION OF ADDITION WILL CONNECT (E) DEATCHED 2-CAR GARAGE (400 SF) TO DWELLING.
- Permit Issued
- Issued on 9/22/2022
- Issuing Office
- Current Status
- Issued on 9/22/2022
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 7/25/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 7/25/2022 | VIVIAN LAO |
| Corrections Issued | 7/26/2022 | VIVIAN LAO |
| Applicant returned to address corrections | 8/24/2022 | VIVIAN LAO |
| Plan Check Approved | 9/20/2022 | VIVIAN LAO |
| Issued | 9/22/2022 | APPLICANT |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 8/4/2022 | CINDY QI |
| Sewer availability | Cleared | 8/4/2022 | CINDY QI |
| Low Impact Development | Cleared | 8/24/2022 | SARAH YOUSSEF |
| Grading Pre-Inspection | Cleared | 9/1/2022 | KIRK LINKLATER |
| Roof/Waste drainage to street | Cleared | 9/15/2022 | AMAAN MALIK |
| Hydrant and Access approval | Cleared | 9/18/2022 | JOHN CONNEALLY |
Contact Information
| Contractor | B & W Holdings Inc; Lic. No.: 968742-B | , |
Inspector Information
| LUIS CASTRO, (213) 202-3436 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Drilled-In Anchors | 10/20/2022 | Approved | ANTHONY EGSON |
| Excavation/Setback/Form/Re-Bar | 10/24/2022 | Partial Inspection | ANTHONY EGSON |
| Footing/Foundation/Slab | 10/28/2022 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Barrier | 10/28/2022 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Subgrade | 10/28/2022 | Not Ready for Inspection | ANTHONY EGSON |
| ELECTRICAL-Rough | 12/29/2022 | Not Ready for Inspection | ANTHONY EGSON |
| PLUMBING-Rough | 12/29/2022 | Not Ready for Inspection | ANTHONY EGSON |
| Wood Frame | 12/29/2022 | Not Ready for Inspection | ANTHONY EGSON |
| ELECTRICAL-Rough | 1/3/2023 | Corrections Issued | ANTHONY EGSON |
| PLUMBING-Rough | 1/3/2023 | Not Ready for Inspection | ANTHONY EGSON |
| Wood Frame | 1/3/2023 | Corrections Issued | ANTHONY EGSON |
| ELECTRICAL-Rough | 2/1/2023 | Approved | ANTHONY EGSON |
| PLUMBING-Rough | 2/1/2023 | Partial Approval | ANTHONY EGSON |
| Wood Frame | 2/1/2023 | Partial Approval | ANTHONY EGSON |
| Floor/Roof Diaphrgm/Shear Wall | 2/7/2023 | Partial Approval | MICHAEL LEWIS |
| HVAC-Rough | 2/7/2023 | Approved | MICHAEL LEWIS |
| Insulation | 2/21/2023 | Corrections Issued | ANTHONY EGSON |
| Drywall Nailing | 2/28/2023 | Approved | ANTHONY EGSON |
| Green Building Rough | 2/28/2023 | Approved | ANTHONY EGSON |
| PLUMBING-Rough | 3/8/2023 | Corrections Issued | ANTHONY EGSON |
| PLUMBING-Rough | 3/14/2023 | Approved | ANTHONY EGSON |
| Interior/Exterior Lathing | 5/24/2023 | Approved | ANTHONY EGSON |
| BUILDING-Rough-Frame | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| ELECTRICAL-Final | 11/21/2023 | Corrections Issued | ANTHONY EGSON |
| Final | 11/21/2023 | Corrections Issued | ANTHONY EGSON |
| Footing/Foundation/Slab | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| Green Building Final | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Barrier | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Final | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Rough | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| METHANE-Subgrade | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| SGSOV-Seismic Gas S/O Valve | 11/21/2023 | SGSOV Approved | ANTHONY EGSON |
| Smoke Detectors | 11/21/2023 | Not Ready for Inspection | ANTHONY EGSON |
| BUILDING-Rough-Frame | 3/28/2025 | Approved | LUIS CASTRO |
| Final | 3/28/2025 | Corrections Issued | LUIS CASTRO |
| Footing/Foundation/Slab | 3/28/2025 | Approved | LUIS CASTRO |
| Green Building Final | 3/28/2025 | Approved | LUIS CASTRO |
| METHANE-Barrier | 3/28/2025 | Approved | LUIS CASTRO |
| METHANE-Final | 3/28/2025 | Approved | LUIS CASTRO |
| METHANE-Rough | 3/28/2025 | Approved | LUIS CASTRO |
| METHANE-Subgrade | 3/28/2025 | Approved | LUIS CASTRO |
| Smoke Detectors | 3/28/2025 | Approved | LUIS CASTRO |
| Final | 5/16/2025 | Not Ready for Inspection | LUIS CASTRO |
| Final | 6/3/2025 | Not Ready for Inspection | LUIS CASTRO |
| Final | 7/16/2025 | Not Ready for Inspection | LUIS CASTRO |