219-221 W 107TH ST 90003
Certificate Information: 219-221 W 107TH ST 90003
- Application / Permit
- 22014-10000-03240
- Plan Check / Job No.
- B22LA12539
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (2) Duplex
- Work Description
- ADDITION TO (E) DUPLEX AT REAR UNIT PER WFPP
- Permit Issued
- Issued on 6/21/2023
- Issuing Office
- Metro
- Current Status
- CofO Issued on 10/10/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 6/28/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 6/28/2022 | FERNANDO FLORES |
| Corrections Issued | 6/29/2022 | FERNANDO FLORES |
| Building Plans Picked Up | 7/25/2022 | APPLICANT |
| Applicant returned to address corrections | 5/9/2023 | GEORGE ALVAREZ |
| Plan Check Approved | 6/20/2023 | MINA HABILI |
| Issued | 6/21/2023 | APPLICANT |
| CofO in Progress | 10/4/2023 | JAMES CHAVEZ |
| Permit Finaled | 10/10/2023 | DANIEL ORRANTE |
| CofO Issued | 10/10/2023 | DANIEL ORRANTE |
| Permit Finaled | 10/10/2023 | DANIEL ORRANTE |
Permit Application Clearance Information
| Tenant Habitability Plan | Cleared | 12/28/2022 | ISMAEL HERNANDEZ |
| Eng Process Fee Ord 176,300 | Cleared | 1/6/2023 | AMAAN MALIK |
| Sewer availability | Cleared | 1/6/2023 | AMAAN MALIK |
| Roof/Waste drainage to street | Cleared | 5/26/2023 | STEVE MELGAR |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| BEN MOLSTAD, (310) 732-4557 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Reinf. Concrete | 6/29/2023 | Conditional Approval | JAMES CHAVEZ |
| Footing/Foundation/Slab | 6/30/2023 | Approved | JAMES CHAVEZ |
| Floor/Roof Diaphrgm/Shear Wall | 7/10/2023 | Partial Approval | JAMES CHAVEZ |
| Green Building Rough | 7/10/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| MERV13>=Rough | 7/10/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| ELECTRICAL-Rough | 7/14/2023 | Corrections Issued | JAMES CHAVEZ |
| ELECTRICAL-Rough | 7/24/2023 | Approved | JAMES CHAVEZ |
| Floor/Roof Diaphrgm/Shear Wall | 7/24/2023 | Partial Approval | JAMES CHAVEZ |
| BUILDING-Rough-Frame | 8/1/2023 | Approved | JAMES CHAVEZ |
| Green Building Rough | 8/1/2023 | Approved | JAMES CHAVEZ |
| HVAC-Rough | 8/1/2023 | Approved | JAMES CHAVEZ |
| MERV13>=Rough | 8/1/2023 | Approved | JAMES CHAVEZ |
| Insulation | 8/3/2023 | Approved | JAMES CHAVEZ |
| Drywall Nailing | 8/7/2023 | Approved | JAMES CHAVEZ |
| Final | 8/29/2023 | Corrections Issued | JAMES CHAVEZ |
| Green Building Final | 8/29/2023 | Not Ready for Inspection | JAMES CHAVEZ |
| MERV13>=Final | 8/29/2023 | Approved | JAMES CHAVEZ |
| SGSOV-Seismic Gas S/O Valve | 8/29/2023 | SGSOV Not Ready | JAMES CHAVEZ |
| Smoke Detectors | 8/29/2023 | Approved | JAMES CHAVEZ |
| Final | 9/6/2023 | Corrections Issued | JOHN KLARIN |
| Green Building Final | 9/6/2023 | Approved | JOHN KLARIN |
| SGSOV-Seismic Gas S/O Valve | 9/6/2023 | SGSOV Approved | JOHN KLARIN |
| Final | 9/12/2023 | OK to Issue CofO | JAMES CHAVEZ |