157 E 85TH ST 90003
Certificate Information: 157 E 85TH ST 90003
- Application / Permit
- 22014-10000-03027
- Plan Check / Job No.
- B22LA11763
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- CONVERT EXISTING DETACHED 1-CAR GARAGE INTO NEW ADU WITH ADDITION PER ORDINANCE, ALL WORK PER WFPP
- Permit Issued
- Issued on 7/21/2023
- Issuing Office
- Metro
- Current Status
- Issued on 7/21/2023
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 6/17/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 6/22/2022 | KHUONG TRUONG |
| Corrections Issued | 6/22/2022 | KHUONG TRUONG |
| Plan Check Approved | 7/19/2023 | MINA HABILI |
| Issued | 7/21/2023 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 7/18/2022 | CINDY QI |
| Eng Process Fee Ord 176,300 | Cleared | 7/25/2022 | CINDY QI |
| Sewer availability | Cleared | 7/25/2022 | CINDY QI |
| Low Impact Development | Cleared | 7/7/2023 | MELINEH AGHAKHABIAN |
| Roof/Waste drainage to street | Cleared | 7/11/2023 | CELINA MORENO |
Contact Information
| Contractor | Owner-Builder | , |
Inspector Information
| JOHN QUINTANILLA, (213) 792-6055 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Pre-Inspection | 8/10/2023 | Approved | MICHAEL LEWIS |
| Excavation/Setback/Form/Re-Bar | 9/11/2023 | Approved | MICHAEL LEWIS |
| Footing/Foundation/Slab | 9/11/2023 | Not Ready for Inspection | MICHAEL LEWIS |
| Underground Mechanical | 9/11/2023 | Approved | MICHAEL LEWIS |
| Deputy Drilled-In Anchors | 9/13/2023 | Conditional Approval | MICHAEL LEWIS |
| Footing/Foundation/Slab | 9/20/2023 | Approved | MICHAEL LEWIS |
| Floor/Roof Diaphrgm/Shear Wall | 10/19/2023 | Corrections Issued | MICHAEL LEWIS |
| Green Building Rough | 10/19/2023 | Not Ready for Inspection | MICHAEL LEWIS |
| Interior/Exterior Lathing | 3/22/2024 | Partial Approval | STUART CHAPMAN |
| Rough-Elec/Plmb/HVAC | 4/8/2024 | Corrections Issued | MICHAEL LEWIS |
| BUILDING-Rough-Frame | 5/15/2024 | Approved | MICHAEL LEWIS |
| ELECTRICAL-Rough | 5/15/2024 | Approved | MICHAEL LEWIS |
| Green Building Rough | 5/15/2024 | Approved | MICHAEL LEWIS |
| PLUMBING-Rough | 5/15/2024 | Approved | MICHAEL LEWIS |
| Sewer | 5/15/2024 | Approved | MICHAEL LEWIS |
| Underground Mechanical | 5/15/2024 | Approved | MICHAEL LEWIS |
| Insulation | 5/28/2024 | Approved | CRAIG DAVIS |
| Drywall Nailing | 6/21/2024 | Approved | JOSH MEISTER |
| Interior/Exterior Lathing | 6/21/2024 | Approved | JOSH MEISTER |
| Final | 12/6/2024 | Not Ready for Inspection | ALEJANDRO DE ARTOLA |
| Verify Rec and Parks Fee Memo | 12/6/2024 | Approved | ALEJANDRO DE ARTOLA |