1202 N COMMONWEALTH AVE 90029
Certificate Information: 1202 N COMMONWEALTH AVE 90029
- Application / Permit
- 22014-10000-01383
- Plan Check / Job No.
- B22LA05216
- Group
- Building
- Type
- Bldg-Addition
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- 2ND FLOOR ADDITION AND INTERIOR/EXTERIOR REMODEL TO EXISTING ONE STORY SFD
- Permit Issued
- Issued on 1/6/2023
- Issuing Office
- Metro
- Current Status
- CofO Issued on 7/29/2024
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 3/30/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 4/7/2022 | STARR CHEN |
| Corrections Issued | 4/14/2022 | STARR CHEN |
| Quality Review Completed | 4/20/2022 | KEN GILL |
| Building Plans Picked Up | 4/25/2022 | APPLICANT |
| Plan Check Approved | 7/13/2022 | STARR CHEN |
| Issued | 1/6/2023 | APPLICANT |
| CofO in Progress | 7/12/2024 | FREDDIE RIVERA |
| Permit Finaled | 7/29/2024 | DEROLD HAUFF |
| CofO Issued | 7/29/2024 | DEROLD HAUFF |
| Permit Finaled | 7/29/2024 | DEROLD HAUFF |
Permit Application Clearance Information
| Permit | Cleared | 4/28/2022 | CINDY QI |
| Roof/Waste drainage to street | Cleared | 4/28/2022 | CINDY QI |
| Sewer availability | Cleared | 4/28/2022 | CINDY QI |
| Eng Process Fee Ord 176,300 | Cleared | 5/2/2022 | CINDY QI |
| Grading Pre-Inspection | Cleared | 6/8/2022 | KIRK LINKLATER |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Phillips,, Craig; Lic. No.: C69673 | 2123 VESTAL AVE LOS ANGELES, CA 90026 |
Inspector Information
| FREDDIE RIVERA, (213) 202-3437 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Excavation/Setback/Form/Re-Bar | 1/24/2023 | Partial Approval | FREDDIE RIVERA |
| Footing/Foundation/Slab | 1/24/2023 | Partial Approval | FREDDIE RIVERA |
| Footing/Foundation/Slab | 2/7/2023 | Approved | FREDDIE RIVERA |
| Reinforced Concrete Frame | 2/7/2023 | Approved | FREDDIE RIVERA |
| BUILDING-Rough-Frame | 2/9/2023 | Partial Approval | FREDDIE RIVERA |
| Insulation | 2/9/2023 | Partial Approval | FREDDIE RIVERA |
| PLUMBING-Rough | 2/9/2023 | Partial Approval | FREDDIE RIVERA |
| Floor/Roof Diaphrgm/Shear Wall | 2/22/2023 | Partial Approval | FREDDIE RIVERA |
| Floor/Roof Diaphrgm/Shear Wall | 3/9/2023 | Corrections Issued | FREDDIE RIVERA |
| BUILDING-Rough-Frame | 3/31/2023 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
| Green Building Rough | 3/31/2023 | Not Ready for Inspection | ALIZAH MAYAGOITIA |
| Rough-Elec/Plmb/HVAC | 3/31/2023 | Approved | ALIZAH MAYAGOITIA |
| BUILDING-Rough-Frame | 4/27/2023 | Conditional Approval | FREDDIE RIVERA |
| Green Building Rough | 4/27/2023 | Partial Inspection | FREDDIE RIVERA |
| Interior/Exterior Lathing | 4/27/2023 | Partial Inspection | FREDDIE RIVERA |
| Insulation | 5/8/2023 | Approved | FREDDIE RIVERA |
| Drywall Nailing | 6/1/2023 | Approved | FREDDIE RIVERA |
| Interior/Exterior Lathing | 6/1/2023 | Approved | FREDDIE RIVERA |
| Wood Frame | 6/1/2023 | Approved | FREDDIE RIVERA |
| Footing/Foundation/Slab | 6/28/2023 | Approved | FREDDIE RIVERA |
| BUILDING-Rough-Frame | 5/30/2024 | Approved | FREDDIE RIVERA |
| ELECTRICAL-Final | 5/30/2024 | Corrections Issued | FREDDIE RIVERA |
| Final | 5/30/2024 | Corrections Issued | FREDDIE RIVERA |
| Green Building Final | 5/30/2024 | Approved | FREDDIE RIVERA |
| Green Building Rough | 5/30/2024 | Approved | FREDDIE RIVERA |
| HVAC-Final | 5/30/2024 | Corrections Issued | FREDDIE RIVERA |
| PLUMBING-Final | 5/30/2024 | Approved | FREDDIE RIVERA |
| SGSOV-Seismic Gas S/O Valve | 5/30/2024 | SGSOV Not Ready | FREDDIE RIVERA |
| Service/Power Release | 5/30/2024 | Partial Inspection | FREDDIE RIVERA |
| Smoke Detectors | 5/30/2024 | Approved | FREDDIE RIVERA |
| Final | 7/10/2024 | OK to Issue CofO | FREDDIE RIVERA |
| SGSOV-Seismic Gas S/O Valve | 7/10/2024 | SGSOV Approved | FREDDIE RIVERA |