3630 S BARRY AVE 90066

Certificate Information: 3630 S BARRY AVE 90066

Application / Permit
22010-30000-00523
Plan Check / Job No.
B22WL00457
Group
Building
Type
Bldg-New
Sub-Type
1 or 2 Family Dwelling
Primary Use
(7) Garage - Private
Work Description
(N) 400 sf detached 2-car garage ***2 of 2 ***
Permit Issued
Issued on 7/8/2022
Issuing Office
Current Status
CofO Issued on 10/30/2024
Certificate of Occupancy
CofO Issued More Information

Permit Application Status History

Submitted 2/3/2022 APPLICANT
Assigned to Plan Check Engineer 3/3/2022 KAVIAN REFAHI
Corrections Issued 3/8/2022 KAVIAN REFAHI
Quality Review Completed 3/11/2022 FELIX FIGUEROA
Building Plans Picked Up 3/11/2022 APPLICANT
Plan Check Approved 6/24/2022 KAVIAN REFAHI
Issued 7/8/2022 APPLICANT
CofO in Progress 10/29/2024 DANIEL VERA
CofO Issued 10/30/2024 RICHARD STEINBACH
Permit Finaled 10/30/2024 RICHARD STEINBACH

Permit Application Clearance Information

GPI Written Notices Cleared 3/8/2022 KAVIAN REFAHI
Grading Pre-Inspection Cleared 3/8/2022 KAVIAN REFAHI
Eng Process Fee Ord 176,300 Cleared 4/21/2022 JENSON LEE
Hydrant and Access approval Cleared 5/3/2022 CINDY JOSSELYN
Construction near power lines Cleared 5/10/2022 RIDWAN HARDY
Low Impact Development Cleared 5/19/2022 CHRIS VONG
Roof/Waste drainage to street Cleared 5/25/2022 CATHERINE ADROVER

Contact Information

Architect Genoist,, Bertrand; Lic. No.: C36796 2606 S BARRINGTON AVE UNIT A      LOS ANGELES, CA 90064
Contractor Hoff-Genoist Ltd; Lic. No.: 1068686-B 2606 SOUTH BARRINGTON AVE A      LOS ANGELES, CA 90064
Engineer Almalla,, Dean; Lic. No.: C58024 15053 VENTURA BLVD STE 205      SHERMAN OAKS, CA 91403

Inspector Information

KIRK SANDERS, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI
ARAM AVEDISIAN, (310) 914-3896 Office Hours: 7:00-8:00 AM MON-FRI

Pending Inspections

No Data Available.

Inspection Request History

Excavation/Setback/Form/Re-Bar 1/26/2023 Approved DAVID FEILER
Footing/Foundation/Slab 1/26/2023 Approved DAVID FEILER
ELECTRICAL-Rough 6/7/2023 Approved EVAN COOPER
Interior/Exterior Lathing 6/7/2023 Approved EVAN COOPER
BUILDING-Rough-Frame 6/9/2023 Approved JOHNNY MIRANDA
Green Building Rough 6/9/2023 Approved JOHNNY MIRANDA
Insulation 6/16/2023 Approved JOHNNY MIRANDA
ELECTRICAL-Final 10/23/2024 Approved DANIEL VERA
Final 10/23/2024 Not Ready for Inspection DANIEL VERA
Green Building Final 10/23/2024 Approved DANIEL VERA
SGSOV-Seismic Gas S/O Valve 10/23/2024 SGSOV Approved DANIEL VERA
Service/Power Release 10/23/2024 Not Ready for Inspection DANIEL VERA
Smoke Detectors 10/23/2024 Approved DANIEL VERA
Final 10/28/2024 OK to Issue CofO DANIEL VERA
Service/Power Release 10/28/2024 Approved DANIEL VERA