11668 N PRAGER AVE 91342
Certificate Information: 11668 N PRAGER AVE 91342
- Application / Permit
- 22010-20000-05887
- Plan Check / Job No.
- B22VN17775
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- eplan NEW DETACHED 2-STORY ADU PER LAMC 12.22 A.33 (c)-(d)
- Permit Issued
- Issued on 4/9/2024
- Issuing Office
- Current Status
- Issued on 4/9/2024
- Certificate of Occupancy
- Pending More Information
Permit Application Status History
| Submitted | 12/5/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 1/5/2023 | MAHNAZ NOURHASHEMI |
| Corrections Issued | 1/11/2023 | MAHNAZ NOURHASHEMI |
| Quality Review Completed | 1/19/2023 | TEODORO DIAZ RODRIGUEZ |
| Applicant returned to address corrections | 1/11/2024 | MAHNAZ NOURHASHEMI |
| Plan Check Approved | 2/26/2024 | MAHNAZ NOURHASHEMI |
| Issued | 4/9/2024 | APPLICANT |
Permit Application Clearance Information
| Address approval | Cleared | 5/16/2023 | DAGOVERTO GUERRERO |
| Hydrant and Access approval | Cleared | 5/16/2023 | MATTHEW CRAIG |
| Low Impact Development | Cleared | 8/18/2023 | ANTHONY VARGAS |
| Roof/Waste drainage to street | Cleared | 8/28/2023 | NIKKI ZULUETA |
| Eng Process Fee Ord 176,300 | Cleared | 10/16/2023 | COLIN LOREDO |
| Sewer availability | Cleared | 10/16/2023 | COLIN LOREDO |
| Grading Pre-Inspection | Cleared | 1/11/2024 | MAHNAZ NOURHASHEMI |
| GPI Written Notices | Cleared | 2/26/2024 | MAHNAZ NOURHASHEMI |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Manoukian,, Krikor Kerop; Lic. No.: C87010 | 2310 W MAGNOLIA BLVD STE A BURBANK, CA 91506 |
Inspector Information
| MICHEL ABAJAN, (818) 374-9932 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Footing/Foundation/Slab | 4/23/2024 | Corrections Issued | MICHEL ABAJAN |
| Footing/Foundation/Slab | 5/1/2024 | Approved | MICHEL ABAJAN |
| Underground Mechanical | 5/6/2024 | Partial Approval | MATTHEW NELSON |
| BUILDING-Rough-Frame | 7/1/2024 | Partial Approval | MICHEL ABAJAN |
| Verify Sprinkler Sign Off | 7/1/2024 | Approved | MICHEL ABAJAN |
| Floor/Roof Diaphrgm/Shear Wall | 10/9/2024 | Partial Approval | MICHEL ABAJAN |
| BUILDING-Rough-Frame | 10/11/2024 | Approved | MICHEL ABAJAN |
| ELECTRICAL-Rough | 10/11/2024 | Approved | MICHEL ABAJAN |
| Green Building Rough | 10/11/2024 | Approved | MICHEL ABAJAN |
| HVAC-Rough | 10/11/2024 | Approved | MICHEL ABAJAN |
| Interior/Exterior Lathing | 10/11/2024 | Not Ready for Inspection | MICHEL ABAJAN |
| PLUMBING-Rough | 10/11/2024 | Approved | MICHEL ABAJAN |
| Insulation | 10/16/2024 | Conditional Approval | MICHEL ABAJAN |
| Interior/Exterior Lathing | 10/16/2024 | Approved | MICHEL ABAJAN |
| Drywall Nailing | 11/1/2024 | Approved | MICHEL ABAJAN |
| Interior/Exterior Lathing | 11/1/2024 | Approved | MICHEL ABAJAN |
| Shower Pan | 11/1/2024 | Approved | MICHEL ABAJAN |
| Underground Mechanical | 4/2/2025 | Approved | MICHEL ABAJAN |
| ELECTRICAL-Final | 10/20/2025 | Approved | MICHEL ABAJAN |