4442 N BEN AVE 91607
Certificate Information: 4442 N BEN AVE 91607
- Application / Permit
- 22010-20000-05486
- Plan Check / Job No.
- B22VN16700
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Dwelling - Single Family
- Work Description
- ePLAN- NEW 2-STORY SFD WITH A NEW ATTACHED GARAGE. NFPA 13D FIRE SPRINKLERS THROUGHOUT
- Permit Issued
- Issued on 7/27/2023
- Issuing Office
- Current Status
- CofO Issued on 1/7/2025
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 11/11/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 11/17/2022 | MAHNAZ NOURHASHEMI |
| Corrections Issued | 11/25/2022 | MAHNAZ NOURHASHEMI |
| Quality Review Completed | 12/2/2022 | GARO TELMI |
| Applicant returned to address corrections | 5/10/2023 | MAHNAZ NOURHASHEMI |
| Applicant returned to address corrections | 5/22/2023 | MAHNAZ NOURHASHEMI |
| Plan Check Approved | 6/5/2023 | MAHNAZ NOURHASHEMI |
| Issued | 7/27/2023 | APPLICANT |
| CofO in Progress | 12/20/2024 | CHRISTOPHER ROJAS |
| Permit Finaled | 1/7/2025 | RUBEN SALAS |
| CofO Issued | 1/7/2025 | RUBEN SALAS |
| Permit Finaled | 1/7/2025 | RUBEN SALAS |
Permit Application Clearance Information
| Eng Process Fee Ord 176,300 | Cleared | 12/1/2022 | COLIN LOREDO |
| Permit | Cleared | 12/1/2022 | COLIN LOREDO |
| Sewer availability | Cleared | 12/1/2022 | COLIN LOREDO |
| Address approval | Cleared | 12/8/2022 | COLIN LOREDO |
| Hydrant and Access approval | Cleared | 12/17/2022 | KURT CORRAL |
| ZI | Cleared | 1/11/2023 | MIGUEL GAMBOA |
| Trees in Parkway | Cleared | 2/13/2023 | ADALBERTO VERA |
| Low Impact Development | Cleared | 2/22/2023 | ERNEST TSE |
| Roof/Waste drainage to street | Cleared | 2/23/2023 | JOHN LIN |
| Disturb/Remove Protected Trees | Cleared | 4/26/2023 | ADALBERTO VERA |
Contact Information
| Architect | Niemerski,, Kenneth Chester; Lic. No.: C23971 | 52 DAWNWOOD LADERA RANCH, CA 92694 |
| Contractor | T J C Home Builders Llc; Lic. No.: 1025507-B | 26880 ALISO VIEJO PKWY STE 200 ALISO VIEJO, CA 92656 |
| Engineer | Nguyen,, Huan; Lic. No.: C64238 | 13831 TYPEE WAY IRVINE, CA 92620 |
Inspector Information
| JAVIER RAMOS JR, (818) 374-1163 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Deputy Reinf. Concrete | 10/23/2023 | Conditional Approval | JUAN VALENZUELA |
| PLUMBING-Rough | 1/12/2024 | Partial Approval | CRAIG DAVIS |
| Underground Mechanical | 1/12/2024 | Partial Approval | CRAIG DAVIS |
| Excavation/Setback/Form/Re-Bar | 1/18/2024 | Approved | KIRK SANDERS |
| Footing/Foundation/Slab | 1/18/2024 | Approved | KIRK SANDERS |
| Floor/Roof Diaphrgm/Shear Wall | 2/8/2024 | Partial Approval | KIRK SANDERS |
| Deputy Wood Construction | 2/27/2024 | Conditional Approval | JUAN VALENZUELA |
| Floor/Roof Diaphrgm/Shear Wall | 2/28/2024 | Partial Approval | KIRK SANDERS |
| Pre-Inspection | 2/28/2024 | Partial Approval | KIRK SANDERS |
| PLUMBING-Rough | 3/7/2024 | Approved | KIRK SANDERS |
| ELECTRICAL-Rough | 3/11/2024 | Approved | JOHN COLEMAN |
| Shower Pan | 3/14/2024 | Approved | DAVID ANDERSON |
| Deputy Wood Construction | 3/19/2024 | Conditional Approval | ROBERT GOLD |
| Floor/Roof Diaphrgm/Shear Wall | 3/21/2024 | Corrections Issued | KIRK SANDERS |
| HVAC-Rough | 3/21/2024 | Approved | KIRK SANDERS |
| BUILDING-Rough-Frame | 4/2/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| Gas Test | 4/2/2024 | Approved | CHRISTOPHER ROJAS |
| Green Building Rough | 4/2/2024 | Approved | CHRISTOPHER ROJAS |
| Interior/Exterior Lathing | 4/2/2024 | Partial Approval | CHRISTOPHER ROJAS |
| MERV13>=Rough | 4/2/2024 | Approved | CHRISTOPHER ROJAS |
| Verify Sprinkler Sign Off | 4/2/2024 | Approved | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 4/10/2024 | Approved | CHRISTOPHER ROJAS |
| Insulation | 4/16/2024 | Approved | MISAEL ESPARZA |
| Drywall Nailing | 4/26/2024 | Approved | ROBERTO PALACIOS-LOPEZ |
| Interior/Exterior Lathing | 7/9/2024 | Approved | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 8/16/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| ELECTRICAL-Final | 8/16/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| PLUMBING-Final | 8/16/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| ELECTRICAL-Final | 8/21/2024 | Approved | CHRISTOPHER ROJAS |
| Gas Test | 8/21/2024 | Not Ready for Inspection | CHRISTOPHER ROJAS |
| PLUMBING-Final | 8/21/2024 | Approved | CHRISTOPHER ROJAS |
| HVAC-Final | 9/5/2024 | Corrections Issued | CHRISTOPHER ROJAS |
| HVAC-Final | 9/10/2024 | Approved | MISAEL ESPARZA |
| Service/Power Release | 11/8/2024 | Approved | CHRISTOPHER ROJAS |
| ELECTRICAL-Final | 11/15/2024 | Partial Inspection | CHRISTOPHER ROJAS |
| BUILDING-Rough-Frame | 12/19/2024 | Approved | CHRISTOPHER ROJAS |
| Final | 12/19/2024 | OK to Issue CofO | CHRISTOPHER ROJAS |
| Green Building Final | 12/19/2024 | Approved | CHRISTOPHER ROJAS |
| MERV13>=Final | 12/19/2024 | Approved | CHRISTOPHER ROJAS |
| SGSOV-Seismic Gas S/O Valve | 12/19/2024 | SGSOV Approved | CHRISTOPHER ROJAS |