6328 N CLEON AVE 91606
Certificate Information: 6328 N CLEON AVE 91606
- Application / Permit
- 22010-20000-04244
- Plan Check / Job No.
- B22VN12944
- Group
- Building
- Type
- Bldg-New
- Sub-Type
- 1 or 2 Family Dwelling
- Primary Use
- (1) Accessory Dwelling Unit
- Work Description
- *EPLAN* NEW 27' X 47' DETACHED ACCESSORY DWELLING UNIT PER LAMC 12.22 A.33(c) and (d)
- Permit Issued
- Issued on 1/23/2023
- Issuing Office
- Current Status
- CofO Issued on 11/27/2023
- Certificate of Occupancy
- CofO Issued More Information
Permit Application Status History
| Submitted | 8/24/2022 | APPLICANT |
| Assigned to Plan Check Engineer | 9/9/2022 | SELLA BENYAMIN |
| Corrections Issued | 9/11/2022 | SELLA BENYAMIN |
| Quality Review Completed | 9/21/2022 | STEVEN KIM |
| Plan Check Approved | 1/19/2023 | SELLA BENYAMIN |
| Issued | 1/23/2023 | APPLICANT |
| CofO in Progress | 10/5/2023 | JOHN HAYES |
| Permit Finaled | 11/27/2023 | RUBEN SALAS |
| CofO Issued | 11/27/2023 | RUBEN SALAS |
| Permit Finaled | 11/27/2023 | RUBEN SALAS |
Permit Application Clearance Information
| Address approval | Cleared | 9/26/2022 | CARLOS AGUILERA |
| Eng Process Fee Ord 176,300 | Cleared | 11/9/2022 | CARLOS AGUILERA |
| Low Impact Development | Cleared | 11/9/2022 | DEBORA LEITE |
| Roof/Waste drainage to street | Cleared | 11/9/2022 | CARLOS AGUILERA |
| Sewer availability | Cleared | 11/9/2022 | CARLOS AGUILERA |
| Construction near power lines | Cleared | 1/9/2023 | TINA MIRANDA |
Contact Information
| Contractor | Owner-Builder | , |
| Engineer | Burnazyan,, Gegam; Lic. No.: C76761 | 3625 BEVERLY RIDGE DRIVE SHERMAN OAKS, CA 91423 |
Inspector Information
| GAREN HAYRAPETYAN, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
| ROBERTO PALACIOS-LOPEZ, (818) 374-1171 | Office Hours: 7:00-8:00 AM MON-FRI |
Pending Inspections
| No Data Available. |
Inspection Request History
| Underground Mechanical | 3/2/2023 | Approved | JOHN HAYES |
| Excavation/Setback/Form/Re-Bar | 3/13/2023 | Approved | MISAEL ESPARZA |
| Footing/Foundation/Slab | 3/13/2023 | Approved | MISAEL ESPARZA |
| BUILDING-Rough-Frame | 4/6/2023 | Not Ready for Inspection | MATTHEW NELSON |
| Floor/Roof Diaphrgm/Shear Wall | 4/6/2023 | Partial Approval | MATTHEW NELSON |
| Green Building Rough | 4/6/2023 | Not Ready for Inspection | MATTHEW NELSON |
| Verify Sprinkler Sign Off | 4/6/2023 | Not Ready for Inspection | MATTHEW NELSON |
| ELECTRICAL-Rough | 5/11/2023 | Approved | JOHN HAYES |
| Floor/Roof Diaphrgm/Shear Wall | 5/11/2023 | Partial Approval | JOHN HAYES |
| HVAC-Rough | 5/11/2023 | Approved | JOHN HAYES |
| PLUMBING-Rough | 5/11/2023 | Approved | JOHN HAYES |
| BUILDING-Rough-Frame | 5/19/2023 | Approved | JOHN HAYES |
| Green Building Rough | 5/19/2023 | Approved | JOHN HAYES |
| Interior/Exterior Lathing | 5/19/2023 | Partial Approval | JOHN HAYES |
| Shower Pan | 5/19/2023 | Approved | JOHN HAYES |
| Verify Sprinkler Sign Off | 5/19/2023 | Approved | JOHN HAYES |
| Insulation | 5/26/2023 | Approved | RYAN SALAZAR |
| Interior/Exterior Lathing | 5/26/2023 | Approved | RYAN SALAZAR |
| Drywall Nailing | 6/6/2023 | Approved | JOHN HAYES |
| Final | 8/25/2023 | Corrections Issued | JOHN HAYES |
| Final | 10/2/2023 | Corrections Issued | JOHN HAYES |
| Green Building Final | 10/2/2023 | Approved | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 10/2/2023 | SGSOV Not Ready | JOHN HAYES |
| Service/Power Release | 10/2/2023 | Not Ready for Inspection | JOHN HAYES |
| Smoke Detectors | 10/2/2023 | Approved | JOHN HAYES |
| Final | 10/5/2023 | OK to Issue CofO | JOHN HAYES |
| Gas Test | 10/5/2023 | Approved | JOHN HAYES |
| SGSOV-Seismic Gas S/O Valve | 10/5/2023 | SGSOV Approved | JOHN HAYES |
| Service/Power Release | 10/5/2023 | Approved | JOHN HAYES |